PHOENIX CONTACT SAC-6P-M12MRM/ 1,5-PVC PE SH SAC-6P-M12MRM/ 1,5-PVC PE SH 1414935 PHOENIX CONTACT Cabo de potência, 6-pólos, PVC, laranja RAL 2003, blind.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-6P-M12MRM/ 1,5-PVC PE SH 1414935 PHOENIX CONTACT Cabo de potência, 6-pólos, PVC, laranja RAL 2003, blind..

SAC-6P-M12MRM/ 1,5-PVC PE SH

1414935

PHOENIX CONTACT

1 Pcs.

Cabo de potência, 6-pólos, PVC, laranja RAL 2003, blindado (Advanced Shielding Technology), Conector angular M12, Codificação M, para extremidade livre do condutor, comprimento de cabo: 1,5 m, para corrente alternada até 8 A / 690 V Power cable, 6-pole, shielded (Advanced Shielding Technology), M12 angled connector, coding: M, to free cable end, cable length: 1.5 m, for alternating current up to 8 A/690 V Power cable, 6-position, PVC, orange RAL 2003, shielded (Advanced Shielding Technology), Plug angled M12, coding: M, on free cable end, cable length: 1.5 m, for AC current up to 8 A/690 V

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Phoenix Contact power cable part SAC-6P-M12MRM/ 1,5-PVC PE SH 1414935 supplies electrical power and connectivity to industrial drives and automation modules. Power distribution cables safely route electrical loads between industrial equipment and supply sources.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Product type: Power cable
  • Application: Power supply
  • Number of positions: 6
  • No. of cable outlets: 1
  • Shielded: yes
  • Coding: M
  • Data management status Article revision: 05
  • Insulation characteristics Overvoltage category: III
  • Degree of pollution: 3
  • Flammability rating according to UL 94: V0
  • Material of grip body: PP
  • Contact material: CuZn
  • Contact surface material: Ni/Au
  • Contact carrier material: PA
  • Material for screw connection: Zinc die-cast, nickel-plated
  • Insulation resistance: ≥ 100 MΩ

More info

▲
Technical data

Product properties
Product typePower cable
ApplicationPower supply
Number of positions6
No. of cable outlets1
Shieldedyes
CodingM
Data management status
Article revision05
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Material of grip bodyPP
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialPA
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties
Insulation resistance≥ 100 MΩ
Nominal voltage UN690 V AC
Nominal current IN8 A

Connector
Connection 1
TypePlug angled M12
Coding typeM (Power)
Connection 2
Typefree cable end

Cable/line
Cable length1.5 m
PVC orange [PVC]
Dimensional drawing
Cable weight192 kg/km
UL AWM Style2570 / 10914 (80°C/1000 V)
Number of positions6
Shieldedyes
Cable typePVC orange [PVC]
Conductor cross section6x 1.5 mm²
Wire diameter incl. insulation2.4 mm ±0.05 mm
External cable diameter10.40 mm ±0.25 mm
Outer sheath, materialPVC
External sheath, colororange RAL 2003
Conductor materialBare Cu litz wires
Material wire insulationPVC
Single wire, colorblack 1, black 2, black 3, black 4, black 5, green/yellow
Thickness, insulation≥ 0.36 mm
Thickness, outer sheathapprox. 0.76 mm
Max. conductor resistance≤ 15 Ω/m (at 20 °C)
Insulation resistance≥ 100 MΩ*km (at 20 °C)
Nominal voltage, cable≤ 1000 V AC
Test voltage≥ 10000 V AC (Spark test)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation52 mm
Smallest bending radius, movable installation104 mm
Dynamic load capacity (bending)Max. bending cycles: 1000000, Bending radius: 10 x D, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s²
Flame resistanceAccording to UL 758/1581 (Cable Flame)
according to UL 758/1581 FT1
According to DIN EN 60332-1-2
Resistance to oilaccording to DIN EN 60811-404, 168 h at 60 °C
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67 (without preloading, as additional test in accordance with IEC 60529)
Ambient temperature (operation)-25 °C ... 85 °C (Plug / socket)

Standards and regulations
Standard designationM12 connector
Standards/specificationsIEC 61076-2-111

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.