View larger
SAC-5PY-0,15FS/2X1,15-920MS-FS 1426161 PHOENIX CONTACT Cable, system bus, CANopen®, 5-pole, PUR halogen-free..
SAC-5PY-0,15FS/2X1,15-920MS-FS
1426161
PHOENIX CONTACT
50 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The SAC-5PY-0,15FS/2X1,15-920MS-FS CANopen system bus cable from Phoenix Contact splits or extends node connections inside industrial automation networks. Fieldbus cabling assemblies allow technicians to daisy-chain devices efficiently across complex machinery lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 5
- Type of electrical connection, field-sided (EF005525): M12
- Type of plug-in contact, field sided (EF006269): Female (bus)
- Positioning cable feed, field-sided (EF005928): Straight
- Type of electrical connection, box-sided (EF005524): M12
- Type of plug-in contact, box-sided (EF008386): Female (bus)
- Positioning cable feed, box-sided (EF005927): Straight
- Cable length (EF000536): 1.15 m
- Halogen free (EF000025): Yes
- With LED indication (EF005950): No
- Screened (EF000881): No
- Vulcanize (EF004115): No
- Rated voltage (EF000228): 48 V
More info
▲Cable, system bus, CANopen®, 5-poles, without halogen free, violet, RAL 4001, shielded, Female straight M12 SPEEDCON, A-coded, on Female angled M12 SPEEDCON, A-coded Male straight M12 SPEEDCON, A-coded, cable length: 1.15 m, all connectors unshielded
Commercial data
| The code for the order | One million four hundred twenty six thousand one hundred sixty one |
|---|---|
| Pieces/pack. | 1 PCS |
| Sales key | BF1CBA - |
| The amount of minimum order | 50 PCS |
| GTIN | Four trillion fifty five billion six hundred twenty six million four hundred forty seven thousand nine hundred twenty six |
| Weight per piece (package included) | 131,622 g |
| Number customs tariff | Eighty five million four hundred forty four thousand two hundred ninety |
Size
| Length. cable | 1.15 m |
|---|
General
| Rating voltage | 48 V AC |
|---|---|
| 60 V DC | |
| N. of poles | Five |
| Signal type/category | CANopen® |
Cable
| Cable type | CAN BUS/DeviceNet |
|---|---|
| Cable type (abbreviation) | Nine hundred twenty |
| UL AWM Style | 21198 (80 °C / 300 V) |
| Structure cable | 2xAWG24/19+2xAWG22/19 |
| Conductor cross section | 2x 0.25 mm2 (data Line) |
| 2x 0.34 mm2 (power supply Voltage) | |
| 1x 0.34 mm2 (flexible Conductors applied) | |
| Signal line AWG | Twenty four |
| Supply voltage AWG | Twenty two |
| Tree conductor signal line | 19x 0.13 mm |
| Structure conductor supply voltage | 19x 0.15 mm |
| Wire diameter including insulation | A 1.95 mm ±0.05 mm (data Line) |
| 1.4 mm ±0.05 mm (power supply Voltage) | |
| Color wire | red-black, blue-white |
| Twisting in pairs | 2-pair conductors |
| Type of shielding in pairs | Aluminium film plastic-coated, side, aluminum outside |
| Lay the entire | 2 pairs around a flexible conductor applied in the center of the soul |
| Shielding | Wire braid tinned copper |
| Cover screen optical | 80 % |
| External sheath, color | purple RAL 4001 |
| Cable outer diameter D | 6.7 mm ±0.3 mm |
| Bend radius, minimum, fixed | 5 x D |
| Bend radius, minimum, flexible | 10 x D |
| The number of cycles of bending | Five million |
| Bend radius | 70 mm |
| Bend radius, minimum, insert cable drag chains | 10 x D |
| Positioning movement | 4.5 m |
| Positioning speed | 3 m/s |
| Acceleration | 3 m/s2 |
| The weight of the cable | 90 kg/km |
| Outer sheath, material | WHILE |
| Material insulation wire | PE foam (data Line) |
| PE (power supply Voltage) | |
| The conductive material | Cu wire, tin-plated |
| Insulation resistance | ≥ 5 GΩ*km (data Line) |
| ≥ 5 GΩ*km (power supply Voltage) | |
| Resistance of the pair | ≤ 181,80 Ω/km (data Line) |
| ≤ 114,80 Ω/km (Voltage supply) | |
| Capacity line | nom. 40 nF/km (data Line) |
| Characteristic impedance | 120 Ω ±10 % (1 MHz) |
| Attenuation | ≤ 22,9 dB/km (with 1 MHz) |
| ≤ 16,4 dB/km (500 kHz) | |
| ≤ 9,5 dB/km (at 125 kHz) | |
| Rated voltage of cable | ≤ 300 V (peak Value, not for strong current) |
| Test voltage wire/wire | 2000 V (50 Hz, 1 min.) |
| Test voltage wire/shield | 2000 V (50 Hz, 1 min.) |
| Flame resistance | UL 1581, Sec. 1060 (FT-1) |
| IEC 60332-1 | |
| In accordance with ISO 6722-1 5.22 (un ECE R 118.01) | |
| The absence of halogens | according to DIN VDE 0472 Part 815 |
| in accordance with IEC 60754-1 | |
| The other resistance | non-adherent |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| -20 °C ... 80 °C (cable, mobile installation) |
Environmental Product Compliance
| REACh SVHC | |
|---|---|
| Lead 7439-92-1 | |
| China RoHS | Period of use conforms to the target without damage to the environment (EFUP): 50 years |
| The information on hazardous substances found in the declaration of the manufacturer under "Downlaods" |
Rankings
eCl@ss
| eCl@ss 6.0 | Twenty seven million two hundred seventy nine thousand two hundred |
|---|---|
| eCl@ss 7.0 | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 9.0 | Twenty seven million sixty thousand three hundred eleven |
ETIM
| ETIM 6.0 | EC001855 |
|---|---|
| ETIM 7.0 | EC001855 |