PHOENIX CONTACT SAC-5P-P12MS/ 3,0-PUR SH SAC-5P-P12MS/ 3,0-PUR SH 1476902 PHOENIX CONTACT Sensor/actuator cable, 5-pole, halogen-free PUR, greyish bl.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-5P-P12MS/ 3,0-PUR SH 1476902 PHOENIX CONTACT Sensor/actuator cable, 5-pole, halogen-free PUR, greyish bl..

SAC-5P-P12MS/ 3,0-PUR SH

1476902

PHOENIX CONTACT

1 Pcs.

Sensor/actuator cable, 5-pole, halogen-free PUR, greyish black RAL 7021, shielded (Advanced Shielding Technology), M12 Push-pull straight connector, coding: A, to free cable end, cable length: 3 m Cable for sensors/actuators Sensor-actuator cable, 5-pin, halogen-free, grey-black RAL 7021, shielded (Advanced Shielding Technology), straight male M12 Push-Pull, coding: A, connected with without circuit, on free conductor end, cable length: 3 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact sensor/actuator cable (part number SAC-5P-P12MS/ 3,0-PUR SH) serves as a critical link for transmitting control signals and operating power between industrial sensors, actuators, and machine control hardware. Shielded configurations protect sensitive signals from electromagnetic interference.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Link: Push-Pull
  • Product Type: Sensor/Actuator Cable
  • No. of poles: 5
  • Application: Standard
  • Number of cable outlets: 1
  • Shielded: Yes
  • Coding: at
  • Insulation characteristics Overvoltage Category: II
  • Degree of pollution: 3
  • Combustibility class according to UL 94: V0
  • Outer Sheath, Material: WHILE
  • Conductor material: Bare Cu Wire
  • Mass Resistivity: ≤ 5 mΩ
  • Insulation Resistance: ≥ 100 MΩ
  • Rated voltage U N: 48 V AC
  • Rated Current I N: 4 A

More info

▲
Technical data

Montage
LinkPush-Pull

Article features
Product TypeSensor/Actuator Cable
No. of poles5
ApplicationStandard
Number of cable outlets1
ShieldedYes
Codingat
Insulation characteristics
Overvoltage CategoryII
Degree of pollution3

Material information
Combustibility class according to UL 94V0
Outer Sheath, MaterialWHILE
Conductor materialBare Cu Wire

Electrical characteristics
Mass Resistivity≤ 5 mΩ
Insulation Resistance≥ 100 MΩ
Rated voltage UN48 V AC
60 V DC
Rated Current IN4 A
Protection Circuitwithout circuit
Conductor resistance max.58 Ω/km

Mechanical characteristics
Mechanical data
Manoeuvring cycles≥ 100
Bending cycles, maximum10000000

Signalling
Status Reportingno
Available Status Indicationno

Connection data
Connection technology
LinkPush-Pull
Conductor connection
LinkPush-Pull

Connectors
Connection 1
typeM12 Straight Push-Pull Male
No. of poles5
Clamping TypePush-Pull
Encoding Typeat
Connection 2
typeFree conductor end

Cable/Line
Cable Length3 m
Halogenated free PUR black [PUR]
Dimensioned Drawing
Line Weight43 kg/km
UL AWM Style20549 / 10493 (80 °C / 300 V)
No. of poles5
ShieldedYes
Cable TypeHalogenated free PUR black [PUR]
Line Signal Conductor Structure42x 0.10 mm
AWG Signal Line22
Conductor cross-section5x 0.34 mm² (Signal Line)
Wire diameter with insulating sheath1.27 mm ±0.02 mm (Signal line)
Conductor Outer Diameter5.25 mm ±0.2 mm
Outer Sheath, MaterialWHILE
Outer sheath, colorgrey-black RAL 7021
Conductor materialBare Cu Wire
Material, Wire InsulationPP
Single conductor, colorbrown, white, blue, black, grey
Insulation wall thickness≥ 0.21 mm
Outer sheath wall thicknessca. 0.5 mm
Full stranding5 conductors around fillers to the core
Optical Shielded Cover80 %
Conductor resistance max.max. 57 Ω/km (at 20 °C)
Insulation Resistance70 GΩ*km (at 20 °C)
Nominal cable voltage300 V (at 20 °C)
Wire-to-wire test voltage3000 V (at 20 °C)
Minimum bending radius, fixed26 mm
Minimum bending radius, movable52 mm (up to +60 °C)
Bending cycles, maximum10000000
Halogen-freeaccording to DIN VDE 0472 Part 815
in accordance with DIN EN 50267-2-1
Flame Resistanceaccording to UL 758/1581 FT2
DIN EN 60332-2-2 (20 s)
Oil Resistanceaccording to DIN EN 60811-2-1
Other ResistanceVery good resistance against acids, lyes and solvents
Resistance to hydrolysis and microbes
Seawater resistant
UV-resistant according to DIN EN ISO 4892-2-A
abrasion resistant
Special featuresfor energy chains
silicone-free
No impregnated varnish substances
Non-adherent surface
Ambient temperature (operating)-40 °C ... 80 °C (cables, fixed installation)
-25 °C ... 80 °C (Cables, movable installation)

Environmental and electrical life conditions
Environmental conditions
Degree of protectionIP65
IP67
Ambient temperature (operating)-25 °C ... 85 °C (connector / female connector)
-40 °C ... 80 °C (cables, fixed installation)
-25 °C ... 80 °C (Cables, movable installation)

Regulations and requirements
Standard DefinitionM12-Push-Pull
Standards/RegulationsIEC 61076-2-010

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.