View larger
TTC-6P-1X2-M-EX-24DC-UT-I 2906824 PHOENIX CONTACT Surge protection, consisting of protective plug and base e..
TTC-6P-1X2-M-EX-24DC-UT-I
2906824
PHOENIX CONTACT
1 Pcs.
Automation > Combined arrester for data networks/MCR-technology
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A modular surge protection assembly, consisting of protective plug and base element, is represented by the Phoenix Contact TTC-6P-1X2-M-EX-24DC-UT-I for safeguarding sensitive automation loops against electrical overvoltages. These compact devices are regularly integrated into control panels to intercept and divert transient surges before they reach vulnerable instruments. Exact pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2906824
- Packing unit: 1 pc
- Catalog page: Page 152 (C-4-2019)
- GTIN: 4055626135861
- Weight per Piece (excluding packing): 60.000 g
- Custom tariff number: 85363010
- Country of origin: DE (Germany)
- Height: 105.8 mm
- Width: 6.2 mm +0.1 mm
- Depth: 100 mm (incl. DIN rail 7.5 mm)
- Ambient temperature (operation): -40 °C ... 85 °C
- Ambient temperature (storage/transport): -40 °C ... 85 °C
- Permissible humidity (operation): 5 % ... 95 %
- Altitude: ≤ 2000 m (amsl (above mean sea level))
- Degree of protection: IP20
- Housing material: PBT
More info
▲Key Commercial Data
| Orderkey | 2906824 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 152 (C-4-2019) |
| GTIN | 4055626135861 |
| Weight per Piece (excluding packing) | 60.000 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 85 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Degree of protection | IP20 |
General
| Housing material | PBT |
|---|---|
| Flammability rating according to UL 94 | V-0 |
| Color | sky blue RAL 5015 |
| Mounting type | DIN rail: TH 35 - 7.5 mm |
| Type | DIN rail module, two-section, divisible |
| Direction of action | Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground |
Protective circuit
| IEC test classification | C1 |
|---|---|
| C2 | |
| C3 | |
| D1 | |
| Nominal voltage UN | 24 V DC |
| Maximum continuous voltage UC | 30 V DC |
| Rated current | 600 mA (40 °C) |
| Operating effective current ICat UC | ≤ 5 µA |
| Residual current IPE | ≤ 1 µA |
| Nominal discharge current In(8/20) µs (line-line) | 5 kA |
| Nominal discharge current In(8/20) µs (line-earth) | 5 kA |
| Pulse discharge current Iimp(10/350) µs (line-line) | 0.5 kA |
| Pulse discharge current Iimp(10/350) µs (line-earth) | 0.5 kA |
| Total discharge current Itotal(8/20) µs | 10 kA |
| Voltage protection level Up(line-line) | ≤ 55 V (C1 - 1 kV/500 A) |
| ≤ 65 V (C2 - 10 kV / 5 kA) | |
| ≤ 55 V (C3 - 100 A) | |
| Voltage protection level Up(line-earth) | ≤ 900 V (C1 - 1 kV/500 A) |
| ≤ 1.05 kV (C2 - 10 kV / 5 kA) | |
| ≤ 1.4 kV (C3 - 100 A) | |
| Voltage protection level Upstatic (line-line) | ≤ 50 V (C1 - 1 kV/500 A) |
| ≤ 65 V (C2 - 10 kV / 5 kA) | |
| Voltage protection level Upstatic (line-earth) | ≤ 900 V (C1 - 1 kV/500 A) |
| ≤ 1.05 kV (C2 - 10 kV / 5 kA) | |
| Response time tA(line-line) | ≤ 1 ns |
| Response time tA(line-earth) | ≤ 100 ns |
| Input attenuation aE, sym. | typ. 0.3 dB (≤ 250 kHz / 150 Ω) |
| Cut-off frequency fg (3 dB), sym. in 150 Ohm system | typ. 940 kHz |
| Capacity (line-line) | typ. 2 nF |
| Resistance per path | 1.65 Ω ±20 % |
| Surge protection fault message | optical |
| Max. required back-up fuse | 630 mA (FF) |
| Impulse durability (line-line) | C1 - 1 kV / 500 A |
| C2 - 10 kV / 5 kA | |
| C3 - 100 A | |
| Impulse durability (line-earth) | C1 - 1 kV / 500 A |
| C2 - 10 kV / 5 kA | |
| C3 - 100 A | |
| D1 - 500 A | |
| Pulse reset time (line-line) | ≤ 700 ms |
| Pulse reset time (line-earth) | ≤ 30 ms |
Connection data
| Connection method | Screw connection |
|---|---|
| Screw thread | M3 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Stripping length | 8 mm |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 12 |
Standards and Regulations
| Standards/specifications | EN 60079-0 2012 + A11:2013 |
|---|---|
| EN 60079-11 2012 | |
| EN 61643-21 2001 + A1:2009 + A2:2013 | |
| IEC 60079-0 2011 (modified) + corrigendum 2012 + corrigendum 2013 | |
| IEC 60079-11 2008 | |
| IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012 |
General
| Maximum inner capacitance Ci | negligible |
|---|---|
| Max. internal inductance Li | negligible |
| Max. input current Ii | 400 mA (T4 / ≤ 50 °C) |
| 350 mA (T6 / ≤ 35 °C) | |
| Max. input voltage Ui | 30 V DC |
| Insulation voltage to ground | > 180 V DC |
| Ambient temperature (operation) | -40 °C ... 35 °C (T6 / 85 °C) |
| -40 °C ... 50 °C (T4 / 135 °C) |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Classifications
eCl@ss
| eCl@ss 4.0 | 27140201 |
|---|---|
| eCl@ss 4.1 | 27130801 |
| eCl@ss 5.0 | 27130801 |
| eCl@ss 5.1 | 27130801 |
| eCl@ss 6.0 | 27130800 |
| eCl@ss 7.0 | 27130807 |
| eCl@ss 8.0 | 27130807 |
| eCl@ss 9.0 | 27130807 |
UNSPSC
| UNSPSC 6.01 | 30212010 |
|---|---|
| UNSPSC 7.0901 | 39121610 |
| UNSPSC 11 | 39121610 |
| UNSPSC 12.01 | 39121610 |
| UNSPSC 13.2 | 39121620 |
| UNSPSC 18.0 | 39121620 |
| UNSPSC 19.0 | 39121620 |
| UNSPSC 20.0 | 39121620 |
| UNSPSC 21.0 | 39121620 |