SAC-5P-MS/ 1,0-923 CAN SCO 1422553 PHOENIX CONTACT Bus system cable SAC-5P-MS/ 1,0-923 CAN SCO 1422553
SAC-5P-MS/ 1,0-923 CAN SCO
1422553
PHOENIX CONTACT
50 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Bus system cables like this Phoenix Contact SAC-5P-MS/ 1,0-923 CAN SCO 1422553 facilitate robust data exchange between distributed industrial network nodes and automation controllers. Shielded communication lines are critical in factory automation to maintain signal integrity against electromagnetic interference.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 5
- Type of electrical connection, box-sided (EF005524): M12
- Type of plug-in contact, box-sided (EF008386): Male (plug)
- Positioning cable feed, box-sided (EF005927): Straight
- Cable length (EF000536): 1 m
- Halogen free (EF000025): Yes
- With LED indication (EF005950): No
- Screened (EF000881): Yes
- Vulcanize (EF004115): No
- Rated current In (EF008250): 4 A
- Rated voltage (EF000228): 48 V
- Degree of protection (IP) (EF005474): IP65
More info
▲Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, silver-gray RAL 7001, shielded, cable length: 1 m, Connector unshielded
Key Commercial Data
| Orderkey | 1422553 |
|---|---|
| Packing unit | 1 |
| GTIN | 4055626306919 |
| Custom tariff number | 85444290 |
Dimensions
| Length of cable | 1 m |
|---|---|
| Stripping length of the free conductor end | 50 mm |
General
| Rated current at 40°C | 4 A |
|---|---|
| Rated voltage | 48 V AC |
| 60 V DC | |
| Number of positions | 5 |
| Coding | A - standard |
| Signal type/category | CANopen® |
| DeviceNet™ | |
| Status display | No |
| Overvoltage category | II |
| Degree of pollution | 3 |
Material
| Flammability rating according to UL 94 | HB |
|---|---|
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Contact carrier material | TPU GF |
| Material of grip body | TPU |
| Material, knurls | Zinc die-cast, nickel-plated |
Standards and Regulations
| Flammability rating according to UL 94 | HB |
|---|
Cable
| Cable type | CAN Bus/DeviceNet drop cable |
|---|---|
| Cable type (abbreviation) | 923 |
| UL AWM style | 21198 (80°C/300 V) |
| Cable structure | 2xAWG24/19+2xAWG22/19 |
| Conductor cross section | 2x 0.25 mm² (Data cable) |
| 2x 0.34 mm² (Power supply) | |
| 1x 0.34 mm² (Drain wire) | |
| AWG signal line | 24 |
| AWG power supply | 22 |
| Conductor structure signal line | 19x 0.13 mm |
| Conductor structure, voltage supply | 19x 0.15 mm |
| Core diameter including insulation | 1.95 mm ±0.05 mm (Data cable) |
| 1.4 mm ±0.05 mm (Power supply) | |
| Wire colors | Red-black, blue-white |
| Twisted pairs | 2 cores to the pair |
| Type of pair shielding | Plastic-coated aluminum foil, aluminum side outside |
| Overall twist | 2 pairs around a drain wire in the center to the core |
| Shielding | Tinned copper braided shield |
| Optical shield covering | 80 % |
| External sheath, color | silver-gray RAL 7001 |
| External cable diameter D | 6.7 mm ±0,3 mm |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Number of bending cycles | 5000000 |
| Bending radius | 70 mm |
| Minimum bending radius, drag chain applications | 10 x D |
| Traversing path | 4.5 m |
| Traversing rate | 3 m/s |
| Acceleration | 3 m/s² |
| Cable weight | 90 kg/km |
| Outer sheath, material | PUR |
| Material conductor insulation | Foamed PE (Data cable) |
| PE (Power supply) | |
| Conductor material | Tin-plated Cu litz wires |
| Insulation resistance | ≥ 5 GΩ*km (Data cable) |
| ≥ 5 GΩ*km (Power supply) | |
| Loop resistance | ≤ 181.80 Ω/km (Data cable) |
| ≤ 114.80 Ω/km (Power supply) | |
| Cable capacity | nom. 40 nF/km (Data cable) |
| Wave impedance | 120 Ω ±10 % (with 1 MHz) |
| Attenuation | ≤ 22.9 dB/km (with 1 MHz) |
| ≤ 16.4 dB/km (At 500 kHz) | |
| ≤ 9.5 dB/km (At 125 kHz) | |
| Nominal voltage, cable | ≤ 300 V (Peak value, not for high-power applications) |
| Test voltage Core/Core | 2000 V (50 Hz, 1 min.) |
| Test voltage Core/Shield | 2000 V (50 Hz, 1 min.) |
| Flame resistance | UL 1581, Sec. 1060 (FT-1) |
| IEC 60332-1 | |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| according to IEC 60754-1 | |
| Other resistance | Low adhesion |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| -20 °C ... 80 °C (cable, flexible installation) |
Classifications
eCl@ss
| eCl@ss 6.0 | 27279200 |
|---|---|
| eCl@ss 7.0 | 27279218 |
| eCl@ss 9.0 | 27060311 |
ETIM
| ETIM 6.0 | EC001855 |
|---|---|