PHOENIX CONTACT SAC-5P-MS/0,25-28R SCO RAIL SAC-5P-MS/0,25-28R SCO RAIL 1559180 PHOENIX CONTACT Sensor/actuator cable, 5-pole, M12 SPEEDCON straight con.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-5P-MS/0,25-28R SCO RAIL 1559180 PHOENIX CONTACT Sensor/actuator cable, 5-pole, M12 SPEEDCON straight con..

SAC-5P-MS/0,25-28R SCO RAIL

1559180

PHOENIX CONTACT

100 Pcs.

Sensor/actuator cable, 5-pole, M12 SPEEDCON straight connector, coding: A, to free cable end, cable length: 0.25 m, For railway applications Cable for sensors/actuators Sensor/actuator cable, 5-position, Plug straight M12 SPEEDCON, coding: A, connected with unwired, on free cable end, cable length: 0.25 m, For railway applications

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact sensor/actuator cable, specifically model SAC-5P-MS/0,25-28R SCO RAIL, is engineered for demanding rolling stock and railway installations where secure data and power transmission is critical. These specialized cables maintain structural integrity and electrical performance under harsh mechanical stress and vibration.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Sensor/actuator cable
  • Number of positions: 5
  • Application: Railway applications
  • No. of cable outlets: 1
  • Shielded: yes
  • Coding: A
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Flammability rating according to UL 94: V0
  • Material of grip body: PA 6.6
  • Contact material: CuSn
  • Contact surface material: Ni/Au
  • Contact carrier material: PA 6.6
  • Material for screw connection: Zinc die-cast, nickel-plated
  • Contact resistance: ≤ 5 mΩ
  • Insulation resistance: ≥ 100 MΩ

More info

▲
Technical data

Notes
GeneralFurther products with variable cable type and variable cable length can be found in the accessories section

Product properties
Product typeSensor/actuator cable
Number of positions5
ApplicationRailway applications
No. of cable outlets1
Shieldedyes
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Material of grip bodyPA 6.6
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties
Contact resistance≤ 5 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A
Protective circuitunwired

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayNo
Status display presentNo

Connector
Connection 1
TypePlug straight M12 SPEEDCON
Number of positions5
Locking typeSPEEDCON
Coding typeA
Connection 2
Typefree cable end

Cable/line
Cable length0.25 m
Shielded black RADOX®[28R]
Dimensional drawing
Shieldedyes
Cable weight70 kg/km
Cable typeShielded black RADOX®
Cable type (abbreviation)28R
External cable diameter6.2 mm ±0.3 mm
Outer sheath, materialPE-X
External sheath, colorblack
Conductor materialTin-plated Cu litz wires
Conductor structure signal line19x 0.18 mm
AWG signal line20
Conductor cross section5x 0.5 mm²
Material wire insulationPE-X
Wire diameter incl. insulation1.43 mm
Single wire, colorwhite 1, white 2, white 3, white 4, white 5
Overall twist5 cores, twisted
ShieldingTinned copper braided shield
Nominal voltage, cable600 V AC (Core-ground, U0)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, Um)
≤ 900 V DC (Core-ground, V0)
≤ 1500 V DC (Line-line)
Test voltage, cable3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
Cable resistance≤ 40.1 Ω/km
Minimum bending radius, fixed installation3 x D
Minimum bending radius, flexible installation4 x D
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Halogen-freein accordance with EN 50267-2-1
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Concentration of fumesBS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume toxicityBS 6853 B.1
EN 50305, 9.2
Fume corrosivenessEN 50267-2-2
Flame resistanceEN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistanceResistance to fuels according to IRM 903, 168 h at 70 °C
Ambient temperature (operation)-25 °C ... 90 °C (Cable, flexible installation)
-50 °C ... 120 °C (cable, fixed installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
Ambient temperature (operation)-40 °C ... 85 °C (Plug / socket)

Standards and regulations
M12
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101
Standard designationShock, vibration
Standards/specificationsEN 50155

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.