Wiring automation equipment requires dependable links like the SAC-5P-M8MSB/0,5-115/M8SIFSB 1030294 PHOENIX CONTACT Sensor/actuator cable, which bridges proximity switches and control systems. Standardized connection assemblies maintain electrical continuity across motion control and process automation applications. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1030294
- Packing unit: 1
- GTIN: 4055626533704
- Custom tariff number: 85444290
- Length of cable: 0.5 m
- Ambient temperature (operation): -25 °C ... 90 °C (Plug / socket)
- Rated current at 40°C: 3 A
- Rated voltage: 30 V
- Number of positions: 5
- Insulation resistance: ≥ 100 MΩ
- Coding: B - inverse
- Standards/regulations: M8 connector IEC 61076-2-104
- Status display: No
- Protective circuit/component: unwired
- Overvoltage category: II
- Degree of pollution: 3
More info
▲General
| Rated current at 40°C | 3 A |
|---|---|
| Rated voltage | 30 V |
| Number of positions | 5 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | B - inverse |
| Standards/regulations | M8 connector IEC 61076-2-104 |
| Status display | No |
| Protective circuit/component | unwired |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Insertion/withdrawal cycles | ≥ 100 |
Standards and Regulations
| Standard designation | M8 connector |
|---|---|
| Standards/regulations | IEC 61076-2-104 |
| Flammability rating according to UL 94 | HB |
Cable
| Cable type | PUR halogen-free black |
|---|---|
| Cable type (abbreviation) | 115 |
| Cable abbreviation | Li9Y11Y |
| UL AWM style | 20549 |
| Conductor cross section | 0.25 mm² |
| AWG signal line | 24 |
| Conductor structure signal line | 32x 0.10 mm |
| Core diameter including insulation | 1.17 mm ±0.02 mm |
| Thickness, insulation | approx. 0.21 mm (Core insulation) |
| approx. 0.7 mm (Outer cable sheath) | |
| Wire colors | Brown, white, blue, black, gray |
| Overall twist | 5 cores, twisted |
| Length of twist, overall twist | 75 mm |
| External sheath, color | black-gray RAL 7021 |
| External cable diameter D | 4.7 mm ±0.15 mm |
| Smallest bending radius, fixed installation | 23.5 mm |
| Smallest bending radius, movable installation | 47 mm |
| Number of bending cycles | 4000000 |
| Bending radius | 47 mm |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Cable weight | 30 kg/km |
| Outer sheath, material | PUR |
| Material, filler | PP |
| Material conductor insulation | PP |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 1 GΩ*km |
| Conductor resistance | ≤ 75 Ω/km |
| Nominal voltage, cable | ≤ 300 V (AC) |
| Test voltage, cable | ≥ 3000 V (AC) |
| Flame resistance | according to UL 758/1581 (horizontal) |
| in accordance with UL 758/1581 FT2 | |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| in accordance with DIN EN 50267-2-1 | |
| Resistance to oil | According to DIN EN 60811-2-1, 168 h at 100°C |
| Other resistance | hydrolysis and microbe resistant |
| Resistant to salt water | |
| Low adhesion | |
| abrasion-resistant | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| -25 °C ... 80 °C (cable, flexible installation) |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |