PHOENIX CONTACT SAC-5P-M12MS/ 5,4-PUR/M12FR VA SAC-5P-M12MS/ 5,4-PUR/M12FR VA 1107922 PHOENIX CONTACT Sensor/actuator cable, 5-position, PUR halogen-free, .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-5P-M12MS/ 5,4-PUR/M12FR VA 1107922 PHOENIX CONTACT Sensor/actuator cable, 5-position, PUR halogen-free, ..

SAC-5P-M12MS/ 5,4-PUR/M12FR VA

1107922

PHOENIX CONTACT

50 Pcs.

Sensor/actuator cable, 5-position, PUR halogen-free, black-gray RAL 7021, Plug straight M12, A - standard, on Socket angled M12, A - standard, cable length: 5.4 m Sensor/actuator cable, 5-pole, halogen-free PUR, greyish black RAL 7021, Straight male connector M12, coding: A, to Angled connection female M12, coding: A, cable length: 5.4 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact produces the SAC-5P-M12MS/ 5,4-PUR/M12FR VA sensor/actuator cable for machine building and automated manufacturing lines. High-grade interconnection cables bridge the gap between peripheral field devices and centralized control systems. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Orderkey: 1107922
  • Packing unit: 1
  • GTIN: 4063151010669
  • Custom tariff number: 85444290
  • Length of cable: 5.4 m
  • Rated current at 40°C: 4 A
  • Rated voltage: 48 V AC
  • Number of positions: 5
  • Insulation resistance: ≥ 100 MΩ
  • Coding: A - standard
  • Standards/regulations: M12 connector IEC 61076-2-101
  • Status display: No
  • Protective circuit/component: unwired
  • Overvoltage category: II
  • Degree of pollution: 3
  • Flammability rating according to UL 94: HB

More info

▲

Key Commercial Data

Orderkey1107922
Packing unit1
GTIN4063151010669
Custom tariff number85444290

Drawings



Circuit diagram
Contact assignment of the M12 plug and the M12 socket

Schematic diagram
Pin assignment M12 male connector, 5-pos., A-coded, male side



Schematic diagram
Pin assignment M12 socket, 5-pos., A-coded, socket side view

Back to top

Dimensions

Length of cable5.4 m
Back to top

General

Rated current at 40°C4 A
Rated voltage48 V AC
60 V DC
Number of positions5
Insulation resistance≥ 100 MΩ
CodingA - standard
Standards/regulationsM12 connector IEC 61076-2-101
Status displayNo
Protective circuit/componentunwired
Overvoltage categoryII
Degree of pollution3
Back to top

Material

Flammability rating according to UL 94HB
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Material, knurlsStainless steel
Sealing materialNBR
Back to top

Standards and Regulations

Standards/specificationsM12 connector IEC 61076-2-101
Flammability rating according to UL 94HB
Back to top

Cable

Cable typePUR halogen-free black
Cable type (abbreviation)PUR
UL AWM style20549
Conductor cross section5x 0.34 mm² (Signal line)
AWG signal line22
Conductor structure signal line42x 0.10 mm
Core diameter including insulation1.27 mm ±0.02 mm (Signal line)
Thickness, insulationapprox. 0.5 mm
Wire colorsbrown, white, blue, black, green-yellow
External sheath, colorblack-gray RAL 7021
External cable diameter D4.55 mm ±0.15 mm
Smallest bending radius, fixed installation23 mm
Smallest bending radius, movable installation46 mm
Number of bending cycles10000000
Bending radius50 mm
Traversing path10 m
Traversing rate3 m/s
Acceleration10 m/s²
Cable weight33 kg/km
Outer sheath, materialPUR
Material conductor insulationPP
Conductor materialBare Cu litz wires
Insulation resistance≥ 16 GΩ*km (at 20 °C)
Conductor resistancemax. 58 Ω/km (at 20 °C)
Nominal voltage, cable300 V
Test voltage, cable3000 V
Special propertiesFlexible cable conduit capable
Silicone-free
Free of substances which would hinder coating with paint or varnish
flexible
Flame resistancein accordance with UL 758/1581 FT2
DIN EN 60332-2-2 (20 s)
Halogen-freein accordance with DIN VDE 0472 part 815
Resistance to oilin accordance with DIN EN 60811-2-1
Other resistanceHighly resistant to acids, alkaline solutions and solvents
hydrolysis and microbe resistant
Resistant to salt water
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (cable, flexible installation)
Back to top

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Back to top

Classifications

eCl@ss

eCl@ss 9.027060311
Back to top

ETIM

ETIM 6.0EC001855
ETIM 7.0EC001855
Back to top

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.