Designed for automated industrial processes, the Phoenix Contact SAC-5P-M12MS/5,0-500 FB sensor/actuator cable connects field-level control components. It ensures dependable signal transfer and robust mechanical protection for automation systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1420992
- Packing unit: 1
- GTIN: 4055626250229
- Custom tariff number: 85444290
- Length of cable: 5 m
- Ambient temperature (operation): -25 °C ... 90 °C (Plug / socket)
- Degree of protection: IP65
- Rated current at 40°C: 4 A
- Rated voltage: 48 V AC
- Number of positions: 5
- Insulation resistance: ≥ 100 MΩ
- Coding: A - standard
- Standards/regulations: M12 connector IEC 61076-2-101
- Status display: No
- Protective circuit/component: unwired
- Overvoltage category: II
More info
▲Sensor/actuator cable, 5-position, PVC, gray RAL 7001, Plug straight M12, A-coded, on free cable end, cable length: 5 m, with high-grade steel knurl
Key Commercial Data
| Orderkey | 1420992 |
|---|---|
| Packing unit | 1 |
| GTIN | 4055626250229 |
| Custom tariff number | 85444290 |
Dimensions
| Length of cable | 5 m |
|---|
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 90 °C (Plug / socket) |
|---|---|
| Degree of protection | IP65 |
| IP67 | |
| IP68 | |
| IP69K |
General
| Rated current at 40°C | 4 A |
|---|---|
| Rated voltage | 48 V AC |
| 60 V DC | |
| Number of positions | 5 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | A - standard |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Status display | No |
| Protective circuit/component | unwired |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Insertion/withdrawal cycles | ≥ 100 |
Material
| Contact material | CuSn |
|---|---|
| Contact surface material | Ni/Au |
| Contact carrier material | PP |
| Material of grip body | PP |
| Material, knurls | Stainless steel 1.4404 |
Standards and Regulations
| Standard designation | M12 connector |
|---|---|
| Standards/regulations | IEC 61076-2-101 |
Cable
| Cable type | PVC gray |
|---|---|
| Cable type (abbreviation) | PVC |
| Cable abbreviation | LiYY |
| UL AWM style | 2464 / 1729 (80°C/300 V) |
| Conductor cross section | 5x 0.34 mm² (Signal line) |
| AWG signal line | 22 |
| Conductor structure signal line | 19x 0.15 mm |
| Core diameter including insulation | 1.26 mm ±0.05 mm |
| Thickness, insulation | ≥ 0.23 mm (Core insulation) |
| Wire colors | brown, white, blue, black, green-yellow |
| Overall twist | 5 wires around filler to the core |
| External sheath, color | gray RAL 7001 |
| Outer sheath thickness | ≥ 0.76 mm |
| External cable diameter D | 5 mm ±0.15 mm |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Cable weight | 51 kg/km |
| Outer sheath, material | PVC |
| Material conductor insulation | PVC |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 200 MΩ*km (at 20 °C) |
| Conductor resistance | max. 57 Ω/km (at 20 °C) |
| Nominal voltage, cable | ≤ 300 V |
| Test voltage, cable | ≥ 3000 V |
| Flame resistance | As per UL-Style 2464 |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| -25 °C ... 80 °C (cable, flexible installation) |
Classifications
eCl@ss
| eCl@ss 8.0 | 27279218 |
|---|---|
| eCl@ss 9.0 | 27060311 |
ETIM
| ETIM 5.0 | EC001855 |
|---|---|
| ETIM 6.0 | EC001855 |