Bus system cable, CANopen, DeviceNet, 5-pole, halogen-free PUR, lilac red RAL 4001, Straight connector M12, coding: B, a Straight female M12, coding: B, cable length: 45 m Cable for sensors/actuators Bus system cable, CANopen®, DeviceNet™, 5-position, Plug straight M12, coding: B, on Socket straight M12, coding: B, cable length: 45 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact model SAC-5P-M12MS/45-920/M12FS operates as a dedicated bus system cable tailored for CANopen and DeviceNet network installations. Pre-assembled data cables of this variety are standard in industrial environments for linking controllers, drives, and decentralized I/O stations together seamlessly. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Data cable preassembled
  • Sensor type: CANopen ®
  • Number of positions: 5
  • No. of cable outlets: 1
  • Shielded: yes
  • Coding: B
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Bus system: CANopen ® /DeviceNet™
  • Signal type/category: CANopen ®
  • Status display: No
  • Status display present: No
  • Contact resistance: ≤ 5 mΩ
  • Insulation resistance: ≥ 100 MΩ
  • Nominal voltage U N: 48 V AC
  • Nominal current I N: 4 A

More info

▲
Technical data

Product properties
Product typeData cable preassembled
Sensor typeCANopen®
Number of positions5
No. of cable outlets1
Shieldedyes
CodingB
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Interfaces
Bus systemCANopen®/DeviceNet™
Signal type/categoryCANopen®
DeviceNet™

Signaling
Status displayNo
Status display presentNo

Electrical properties
Contact resistance≤ 5 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Material specifications
Flammability rating according to UL 94HB
Seal materialNBR
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Connector
Connection 1
TypePlug straight M12
Number of positions5
Coding typeB (inverse)
Connection 2
TypeSocket straight M12
Number of positions5
Coding typeB

Cable/line
Cable length45 m
CANopen®/DeviceNet™, PUR, violet [920]
Dimensional drawing
Cable weight90 kg/km
UL AWM Style21198 (80°C/300 V)
Number of positions4
Shieldedyes
Cable typeCANopen®/DeviceNet™, PUR, violet [920]
Conductor structure2xAWG24/19+2xAWG22/19
Conductor structure signal line19x 0.13 mm
AWG signal line24
Conductor cross section2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
Wire diameter incl. insulation1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
External cable diameter6.7 mm ±0.3 mm
Outer sheath, materialPUR
External sheath, colorred lilac RAL 4001
Conductor materialTin-plated Cu litz wires
Material wire insulationFoamed PE (Data cable)
PE (Power supply)
Single wire, colorred-black, blue-white
Twisted pairs2 cores to the pair
Type of pair shieldingPlastic-coated aluminum foil, aluminum side outside
Overall twist2 pairs around a drain wire in the center to the core
Optical shield covering80 %
Insulation resistance≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Loop resistance≤ 181.80 Ω/km (Data cable)
≤ 114.80 Ω/km (Power supply)
Wave impedance120 Ω ±10 % (with 1 MHz)
Cable capacitynom. 40 nF/km (Data cable)
Nominal voltage, cable≤ 300 V (Peak value, not for high-power applications)
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000 V (50 Hz, 1 min.)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation34 mm
Smallest bending radius, movable installation67 mm
Max. bending cycles5000000
Shield attenuation≤ 22.9 dB/km (with 1 MHz)
≤ 16.4 dB/km (At 500 kHz)
≤ 9.5 dB/km (At 125 kHz)
Halogen-freein accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Flame resistanceUL 1581, Section 1060 and UL 2556, Section 9.3 (FT1)
UL 1581, Section 1100 and UL 2556, Section 9.1 (HFT/FT2)
IEC 60332-1-2
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistanceLow adhesion
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-30 °C ... 70 °C (Cable, flexible installation)
-20 °C ... 60 °C (for installation)
-20 °C ... 60 °C (cable, drag chain applications)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
IP68
Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 75 °C (Cable, flexible installation)