SAC-5P-M12MS/ 2,0-802/M12FR-3L 1454493 PHOENIX CONTACT Sensor/actuator cable
SAC-5P-M12MS/ 2,0-802/M12FR-3L
1454493
PHOENIX CONTACT
1 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Sensor/actuator cable engineered by Phoenix Contact, identified as part number SAC-5P-M12MS/ 2,0-802/M12FR-3L, facilitates signal integration in automated systems. These dependable lines are commonly deployed to interconnect sensors, actuators, and visual status indicators in control cabinets. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1454493
- Packing unit: 1
- GTIN: 4046356578202
- Custom tariff number: 85444290
- Length of cable: 2 m
- Ambient temperature (operation): -25 °C ... 90 °C (Plug / socket)
- Degree of protection: IP65
- Rated current at 40°C: 4 A
- Rated voltage: 24 V
- Number of positions: 5
- Insulation resistance: ≥ 100 MΩ
- Coding: A - standard
- Status display: 3 LEDs
- Overvoltage category: II
- Degree of pollution: 3
- Flammability rating according to UL 94: HB
More info
▲Ambient conditions
| Ambient temperature (operation) | -25 °C ... 90 °C (Plug / socket) |
|---|---|
| Degree of protection | IP65 |
| IP67 | |
| IP68 |
General
| Rated current at 40°C | 4 A |
|---|---|
| Rated voltage | 24 V |
| 24 V DC | |
| Number of positions | 5 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | A - standard |
| Status display | 3 LEDs |
| Overvoltage category | II |
| Degree of pollution | 3 |
Material
| Flammability rating according to UL 94 | HB |
|---|---|
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Contact carrier material | TPU GF |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Material, knurls | Zinc die-cast, nickel-plated |
| Sealing material | NBR |
Cable
| Note | Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments. |
|---|---|
| Cable type | PUR, halogen-free, highly stranded, resistant to welding sparks, gray |
| Cable type (abbreviation) | 802 |
| Cable abbreviation | Li12Y11Y-HF |
| Conductor cross section | 5x 0.34 mm² (Signal line) |
| AWG signal line | 22 |
| Conductor structure signal line | 42x 0.10 mm |
| Core diameter including insulation | 1.3 mm ±0.05 mm (Signal line) |
| Wire colors | Black, brown, blue, white, green/yellow |
| Overall twist | 5 wires around filler to the core |
| External sheath, color | gray RAL 7001 |
| External cable diameter D | 5.1 mm ±0.2 mm |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 5 x D |
| Number of bending cycles | 10000000 |
| Minimum bending radius, drag chain applications | 7,5 x D |
| Traversing path | 5 m |
| Traversing rate | 3.3 m/s |
| Acceleration | 5 m/s² |
| Number of bending cycles | 15000000 |
| Bending radius | 50 mm |
| Traversing path | 0.9 m |
| Traversing rate | 5 m/s |
| Acceleration | 30 m/s² |
| Torsion force | ± 360 °/m (1 000 000 torsion cycles) |
| Outer sheath, material | PUR |
| Material conductor insulation | PES |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 20 MΩ*km |
| Conductor resistance | approx. 53 Ω/km |
| Nominal voltage, cable | 300 V |
| Test voltage, cable | 1200 V |
| Special properties | Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing |
| Free from silicone and cadmium | |
| Free of substances which would hinder coating with paint or varnish | |
| Flame resistance | DIN VDE 0472 part 804, test type B |
| IEC 60332-1 | |
| in acc. with UL FT-2 | |
| Halogen-free | The cable is halogen-free |
| Resistance to oil | according to VDE 0472 Part 803 |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| Silicone-free | |
| Ambient temperature (operation) | -40 °C ... 90 °C (cable, fixed installation) |
| -30 °C ... 90 °C (cable, flexible installation) | |
| to 120 °C (for 3000 h) |