PHOENIX CONTACT SAC-5P-M12MS/10,0-921/M12FS SAC-5P-M12MS/10,0-921/M12FS 1401773 PHOENIX CONTACT Sensor/actuator cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-5P-M12MS/10,0-921/M12FS 1401773 PHOENIX CONTACT Sensor/actuator cable

SAC-5P-M12MS/10,0-921/M12FS

1401773

PHOENIX CONTACT

50 Pcs.

Sensor/actuator cable Sensor/actuator cable, M12 straight connector, encoding: A, to M12 straight female, coding: A, cable length: 10 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact model SAC-5P-M12MS/10,0-921/M12FS is a sensor/actuator cable utilized for interconnecting measurement devices and feedback sensors in industrial applications. Standardized circular connectors ensure secure, vibration-resistant links across automated plant floors. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Type of electrical connection, field-sided (EF005525): M12
  • Type of plug-in contact, field sided (EF006269): Female (bus)
  • Positioning cable feed, field-sided (EF005928): Straight
  • Type of electrical connection, box-sided (EF005524): M12
  • Type of plug-in contact, box-sided (EF008386): Male (plug)
  • Positioning cable feed, box-sided (EF005927): Straight
  • Cable length (EF000536): 10 m
  • Halogen free (EF000025): Yes
  • With LED indication (EF005950): No
  • Screened (EF000881): Yes
  • Vulcanize (EF004115): No
  • Rated voltage (EF000228): 48 V

More info

▲

Key Commercial Data

Orderkey1401773
Packing unit1
GTIN4046356911870
Custom tariff number85444290

Dimensions

Length of cable10 m

General

Rated voltage48 V AC
60 V DC
Insertion/withdrawal cycles≥ 100

Cable

Cable typeCAN bus/DeviceNet™, black
Cable type (abbreviation)921
UL AWM style21198 (80°C/300 V)
Cable structure2xAWG24/19+2xAWG22/19
Conductor cross section2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
AWG signal line24
AWG power supply22
Conductor structure signal line19x 0.13 mm
Conductor structure, voltage supply19x 0.15 mm
Core diameter including insulation1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
Wire colorsRed-black, blue-white
Twisted pairs2 cores to the pair
Type of pair shieldingPlastic-coated aluminum foil, aluminum side outside
Overall twist2 pairs around a drain wire in the center to the core
ShieldingTinned copper braided shield
Optical shield covering80 %
External sheath, colorblack RAL 9005
External cable diameter D6.7 mm ±0,3 mm
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Number of bending cycles5000000
Bending radius70 mm
Minimum bending radius, drag chain applications10 x D
Traversing path4.5 m
Traversing rate3 m/s
Acceleration3 m/s²
Cable weight90 kg/km
Outer sheath, materialPUR
Material conductor insulationFoamed PE (Data cable)
PE (Power supply)
Conductor materialTin-plated Cu litz wires
Insulation resistance≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Loop resistance≤ 181.80 Ω/km (Data cable)
≤ 114.80 Ω/km (Power supply)
Cable capacitynom. 40 nF/km (Data cable)
Wave impedance120 Ω ±10 % (with 1 MHz)
Attenuation≤ 22.9 dB/km (with 1 MHz)
≤ 16.4 dB/km (At 500 kHz)
≤ 9.5 dB/km (At 125 kHz)
Nominal voltage, cable≤ 300 V (Peak value, not for high-power applications)
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000 V (50 Hz, 1 min.)
Flame resistanceUL 1581, Sec. 1060 (FT-1)
IEC 60332-1
Halogen-freein accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Other resistanceLow adhesion
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.