View larger
SAC-5P-M12MS/1,0-28X/M12FS OD 1057278 PHOENIX CONTACT Sensor/actuator cable SAC-5P-M12MS/1,0-28X/M12FS OD 10..
SAC-5P-M12MS/1,0-28X/M12FS OD
1057278
PHOENIX CONTACT
50 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact sensor/actuator cable (SAC-5P-M12MS/1,0-28X/M12FS OD) is engineered to route signals and operating voltage between decentralized field devices and I/O modules. Robust wiring components protect data integrity and control signals against vibration and mechanical stress.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 5
- Type of electrical connection, field-sided (EF005525): M12
- Type of plug-in contact, field sided (EF006269): Male (plug)
- Positioning cable feed, field-sided (EF005928): Straight
- Type of electrical connection, box-sided (EF005524): M12
- Type of plug-in contact, box-sided (EF008386): Female (bus)
- Positioning cable feed, box-sided (EF005927): Straight
- Cable length (EF000536): 1 m
- Halogen free (EF000025): Yes
- With LED indication (EF005950): No
- Screened (EF000881): No
- Cable type (EF000081): Multi-core
- Vulcanize (EF004115): Yes
- Material contact body (EF008248): CuSn
- Rated current In (EF008250): 4 A
- Rated voltage (EF000228): 48 V
More info
▲Sensor/actuator cable, 5-position, PE-X halogen-free, black-gray RAL 7021, Plug straight M12, A-coded, on Socket straight M12, A-coded, cable length: 1 m, for outdoor applications, with high-grade steel knurl
Key Commercial Data
| Orderkey | 1057278 |
|---|---|
| Packing unit | 1 |
| GTIN | 4055626698687 |
| Custom tariff number | 85444290 |
Dimensions
| Length of cable | 1 m |
|---|
General
| Rated current at 40°C | 4 A |
|---|---|
| Rated voltage | 48 V AC |
| 60 V DC | |
| Number of positions | 5 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | A - standard |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Status display | No |
| Protective circuit/component | unwired |
| Degree of pollution | 3 |
| Insertion/withdrawal cycles | ≥ 100 |
Material
| Flammability rating according to UL 94 | V0 |
|---|---|
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Contact carrier material | PP |
| Material of grip body | PP |
| Material, knurls | Stainless steel |
| Sealing material | FPM |
Standards and Regulations
| Standard designation | M12 connector |
|---|---|
| Standards/regulations | IEC 61076-2-101 |
| Flammability rating according to UL 94 | V0 |
Cable
| Cable type | PE-X black |
|---|---|
| Cable type (abbreviation) | 28X |
| Cable abbreviation | Li2X2X |
| Conductor cross section | 5x 0.5 mm² |
| AWG signal line | 20 |
| Conductor structure signal line | 28x 0.15 mm |
| Core diameter including insulation | 1.6 mm ±0.5 mm |
| Thickness, insulation | approx. 0.3 mm (Core insulation) |
| Wire colors | Brown, white, blue, black, gray |
| Overall twist | 5 wires around filler to the core |
| Length of twist, overall twist | 68 mm |
| External sheath, color | black-gray RAL 7021 |
| Outer sheath thickness | approx. 1.25 mm |
| External cable diameter D | 6.8 mm ±0.2 mm |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Number of bending cycles | 2000000 |
| Minimum bending radius, drag chain applications | 10 x D |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Cable weight | 70 kg/km |
| Outer sheath, material | PE-X |
| Material, filler | PP yarn |
| Material conductor insulation | PE-X |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 100 MΩ*km (at 20 °C) |
| Conductor resistance | ≤ 39 Ω/m (at 20 °C) |
| Nominal voltage, cable | ≤ 300 V AC |
| Test voltage, cable | ≥ 3000 V AC (Spark test) |
| Special properties | Irradiated |
| Flame resistance | According to DIN EN 60332-1-2 |
| according to DIN EN 50266-2-5 | |
| according to IEC 60332-3-25 (bunched fire test) | |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| in accordance with DIN EN 50267-2-1 | |
| Resistance to oil | According to DIN EN 60811-2-1, 168 h at 100°C |
| According to DIN EN 50306 | |
| Other resistance | Resistance to fuels according to IEC 60811, 168 h at 70°C |
| UV resistant according to DIN VDE 0276-605 | |
| Ambient temperature (operation) | -40 °C ... 105 °C (cable, fixed installation) |
| -15 °C ... 105 °C (cable, flexible installation) | |
| 20 °C ±5 °C (cable, drag chain applications) |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |
Classifications
eCl@ss
| eCl@ss 4.0 | 27060306 |
|---|---|
| eCl@ss 4.1 | 27060306 |
| eCl@ss 5.0 | 27061801 |
| eCl@ss 5.1 | 27061801 |
| eCl@ss 6.0 | 27279200 |
| eCl@ss 7.0 | 27279218 |
| eCl@ss 8.0 | 27279218 |
| eCl@ss 9.0 | 27060311 |
ETIM
| ETIM 2.0 | EC000830 |
|---|---|
| ETIM 3.0 | EC001855 |
| ETIM 4.0 | EC001855 |
| ETIM 5.0 | EC001855 |
| ETIM 6.0 | EC001855 |
| ETIM 7.0 | EC001855 |
UNSPSC
| UNSPSC 6.01 | 31251501 |
|---|---|
| UNSPSC 7.0901 | 31251501 |
| UNSPSC 11 | 31251501 |
| UNSPSC 12.01 | 31251501 |
| UNSPSC 13.2 | 31251501 |