PHOENIX CONTACT SAC-5P-M12MS/0,5-92X/M12FSSHOD SAC-5P-M12MS/0,5-92X/M12FSSHOD 1072345 PHOENIX CONTACT Bus system cable, CANopen View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-5P-M12MS/0,5-92X/M12FSSHOD 1072345 PHOENIX CONTACT Bus system cable, CANopen

SAC-5P-M12MS/0,5-92X/M12FSSHOD

1072345

PHOENIX CONTACT

50 Pcs.

Bus system cable, CANopen Bus System Cable, CANopen®, 5-Pole Halogen-Free, Shielded, M12 Straight Connector, Encoding: A, to M12 Straight Female, Coding: A, Cable Length: 0.5 m, for Outdoor Applications Bus system cable, CANopen®, 5-position, FRNC halogen-free, black, shielded, Plug straight M12, coding: A, on Socket straight M12, coding: A, cable length: 0.5 m, for outdoor applications

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact bus system cable, CANopen, designated as part number SAC-5P-M12MS/0,5-92X/M12FSSHOD, supports standardized network communication in distributed automation setups. Controller area networks utilize specialized cabling assemblies to maintain synchronized data exchange between industrial nodes. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Data cable preassembled
  • Sensor type: CANopen®
  • Number of positions: 5
  • Data management status Article revision: 02
  • Signal type/category: CANopen®
  • Connection 1 Type: Plug straight M12
  • Number of positions: 5
  • Coding type: A (Standard)
  • Connection 2 Type: Socket straight M12
  • Number of positions: 5
  • Coding type: A (Standard)
  • Cable length: 0.5 m
  • Cable weight: 70 kg/km
  • UL AWM Style: 21281 (80°C/300 V)
  • Number of positions: 4
  • Shielded: yes

More info

▲
Technical data

Product properties
Product typeData cable preassembled
Sensor typeCANopen®
Number of positions5
Data management status
Article revision02

Interfaces
Signal type/categoryCANopen®

Connector
Connection 1
TypePlug straight M12
Number of positions5
Coding typeA (Standard)
Connection 2
TypeSocket straight M12
Number of positions5
Coding typeA (Standard)

Cable/line
Cable length0.5 m
CANopen®/DeviceNet™ outdoor installation, FRNC, black [92X]
Dimensional drawing
Cable weight70 kg/km
UL AWM Style21281 (80°C/300 V)
Number of positions4
Shieldedyes
Cable typeCANopen®/DeviceNet™ outdoor installation, FRNC, black [92X]
Conductor structure2xAWG24/19+2xAWG22/19
Signal runtime4.46 ns/m
Conductor structure signal line19x 0.13 mm
AWG signal line24
Conductor cross section2x 0.25 mm² (Signal)
2x 0.34 mm² (Power)
1x 0.38 mm² (Drain wire)
Wire diameter incl. insulation1.9 mm (Signal)
1.4 mm (Power)
External cable diameter6.90 mm ±0.3 mm
Outer sheath, materialFRNC
External sheath, colorblack
Conductor materialTin-plated Cu litz wires
Material wire insulationPE
Single wire, colorred-black, blue-white
Thickness, insulation0.60 mm (Signal)
0.30 mm (Power)
Thickness, outer sheath1.15 mm
Twisted pairs2 cores to the pair
Type of pair shieldingAluminum-lined foil
Overall twist2 pairs around a drain wire in the center to the core
Optical shield covering70 %
Max. conductor resistance90 Ω/km (Signal)
55 Ω/km (Power)
Insulation resistance≥ 200 MΩ*km (at 20 °C)
Wave impedance120 Ω ±12 Ω (f = 1 MHz)
Working capacitance39.8 nF (at 1 kHz, core/core)
Nominal voltage, cable≤ 300 V
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000.00 V (50 Hz, 1 min.)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation35 mm
Smallest bending radius, movable installation69 mm
Halogen-freeyes
Flame resistanceAccording to IEC 60332-3-25 (Cat. D)
Resistance to oilyes
Other resistanceUV resistant
Ambient temperature (operation)-40 °C ... 105 °C
Ambient temperature (installation)-40 °C ... 105 °C

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.