Phoenix Contact part number SAC-5P-M12MR/3,0-PUR BK 1584375 is a sensor/actuator cable engineered to interface field-level sensors, actuators, and controllers in automated industrial processes. Angled and straight connector options help optimize physical routing within constrained machine enclosures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Sensor/actuator cable
- Number of positions: 5
- Application: Standard
- No. of cable outlets: 1
- Shielded: no
- Coding: A
- Insulation characteristics Overvoltage category: II
- Degree of pollution: 3
- Flammability rating according to UL 94: HB
- Seal material: NBR
- Material of grip body: TPU, hardly inflammable, self-extinguishing
- Contact material: CuSn
- Contact surface material: Ni/Au
- Contact carrier material: TPU GF
- Material for screw connection: Zinc die-cast, nickel-plated
- Contact resistance: ≤ 5 mΩ
More info
▲| Product type | Sensor/actuator cable |
| Number of positions | 5 |
| Application | Standard |
| No. of cable outlets | 1 |
| Shielded | no |
| Coding | A |
| Insulation characteristics | |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Flammability rating according to UL 94 | HB |
| Seal material | NBR |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Contact carrier material | TPU GF |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Contact resistance | ≤ 5 mΩ |
| Insulation resistance | ≥ 100 MΩ |
| Nominal voltage UN | 48 V AC |
| 60 V DC | |
| Nominal current IN | 4 A |
| Protective circuit | unwired |
| Mechanical data | |
| Insertion/withdrawal cycles | ≥ 100 |
| Status display | No |
| Status display present | No |
| Connection 1 | |
| Type | Plug angled M12 |
| Number of positions | 5 |
| Coding type | A |
| Connection 2 | |
| Type | free cable end |
| Cable length | 3 m |
| PUR halogen-free black [PUR] | |
| Dimensional drawing | |
| Shielded | no |
| UL AWM Style | 20549 |
| Cable weight | 33 kg/km |
| Cable type | PUR halogen-free black |
| Cable type (abbreviation) | PUR |
| External cable diameter | 4.55 mm ±0.15 mm |
| Outer sheath, material | PUR |
| External sheath, color | black-gray RAL 7021 |
| Conductor material | Bare Cu litz wires |
| Conductor structure signal line | 42x 0.10 mm |
| AWG signal line | 22 |
| Conductor cross section | 5x 0.34 mm² (Signal line) |
| Material wire insulation | PP |
| Thickness, insulation | approx. 0.5 mm |
| Wire diameter incl. insulation | 1.27 mm 0.05 mm (Signal line) |
| Single wire, color | brown, white, blue, black, green-yellow |
| Nominal voltage, cable | 300 V |
| Test voltage, cable | 3000 V |
| Cable resistance | max. 58 Ω/km (at 20 °C) |
| Cable insulation resistance | ≥ 16 GΩ*km (at 20 °C) |
| Smallest bending radius, fixed installation | 23 mm |
| Smallest bending radius, movable installation | 46 mm |
| Number of bending cycles | 4000000 |
| Bending radius | 50 mm |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Flame resistance | in accordance with UL 758/1581 FT2 |
| DIN EN 60332-2-2 (20 s) | |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| hydrolysis and microbe resistant | |
| Resistant to salt water | |
| partly UV-resistant in accordance with DIN EN ISO 4892-2-A | |
| Special properties | Flexible cable conduit capable |
| Silicone-free | |
| Free of substances which would hinder coating with paint or varnish | |
| flexible | |
| Ambient temperature (operation) | -25 °C ... 80 °C (Cable, flexible installation) |
| -40 °C ... 80 °C (cable, fixed installation) | |
| Ambient conditions | |
| Degree of protection | IP65 |
| IP67 | |
| IP68 | |
| Ambient temperature (operation) | -25 °C ... 90 °C (Plug / socket) |
| Standard designation | M12 connector |
| Standards/specifications | IEC 61076-2-101 |