View larger
SAC-5P-100,0-28R RAIL 0,5 1559186 PHOENIX CONTACT By meters, Sensor/actuator cable, shielded, halogen-free P..
SAC-5P-100,0-28R RAIL 0,5
1559186
PHOENIX CONTACT
1 Pcs.
Cables > Data and communication cable
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact SAC-5P-100,0-28R RAIL 0,5 is a specialized halogen-free shielded cable by the meter engineered specifically to meet stringent railway application standards. Rolling stock and mass transit electrical systems require specialized rugged cables that withstand harsh environmental conditions and fire safety regulations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: Data cable by the meter
- Number of poles: 5
- application: Railway applications
- Shielded: Yes
- Cable length: 100 m
- Shielded: Yes
- Cable Weight: 70 kg/km
- Cable type: RADOX ® black, shielded
- Cable Type (abbreviation): 28R
- Cable Outer Diameter: 6.2 mm ±0.3 mm
- Outer Wrap, Material: PE-X
- Outer Wrap, Color: black
- Conductive Material: Tinned Cu Conductor
- Conductor Construction Signal Cable: 19x 0.18 mm
- AWG Signal Line: 20
- Line Section: 5x 0.5 mm²
More info
▲| Product Type | Data cable by the meter |
| Number of poles | 5 |
| application | Railway applications |
| Shielded | Yes |
| Cable length | 100 m |
| RADOX®black, shielded [28R] | |
| Dimension Scheme | |
| Shielded | Yes |
| Cable Weight | 70 kg/km |
| Cable type | RADOX®black, shielded |
| Cable Type (abbreviation) | 28R |
| Cable Outer Diameter | 6.2 mm ±0.3 mm |
| Outer Wrap, Material | PE-X |
| Outer Wrap, Color | black |
| Conductive Material | Tinned Cu Conductor |
| Conductor Construction Signal Cable | 19x 0.18 mm |
| AWG Signal Line | 20 |
| Line Section | 5x 0.5 mm² |
| Material: Conductor Insulation | PE-X |
| Conductor diameter incl. insulation | 1.43 mm |
| Single Driver, Color | White 1, White 2, White 3, White 4, White 5 |
| Total cabling | 5 longitudinally stranded conductors |
| Screening | Tinned Copper Wire Mesh |
| Nominal Voltage Cable | 600 V AC (Conductive-Ground, U)0) |
| 1000 V AC (Conduct-to-Earth, U) | |
| ≤ 720 V AC (conductive-ground) | |
| ≤ 1200 V AC (Ground-Conductor, U)m) | |
| ≤ 900 V DC (Conductive-Ground, V0) | |
| ≤ 1500 V DC (conductor-conductor) | |
| Test Voltage Cable | 3500 V AC (50 Hz, 5 min.) |
| 8400 V DC (50 Hz, 5 min.) | |
| Line Resistance | ≤ 40.1 Ω/km |
| Minimum bending radius, fixed | 3 x D |
| Minimum bending radius, flexibly positioned | 4 x D |
| Fire protection in vehicles on rails | BS 6853 (Category Ia, Ib, II) |
| GM/RT 2130 (Category Ia, Ib, II) | |
| EN 45545 (Hazard Level HL1 - HL3) | |
| DIN 5510 (Fire Protection Level 1, 2, 3, 4) | |
| NF F16-101 (Category A1, A2, B) | |
| NF F16-101 (Class C / F0) | |
| NFPA 130 | |
| UNI IEC 11170 (Hazard Level LR1 - LR4) | |
| Absence of halogens | according to EN 50267-2-1 |
| Oil Resistance | according to IRM 902, 72 h at 100 °C |
| Flue gas density | BS 6853 D.8.7 |
| EN 61034-2 | |
| UL 1685, 12 (FT4) | |
| Fire Gas Toxicity | BS 6853 B.1 |
| EN 50305, 9.2 | |
| Corrosion of fire gases | EN 50267-2-2 |
| Flame Resistance | EN 60332-1-2 |
| EN 50266 | |
| EN 60332-3-25 | |
| NF C32-070, 2.1 | |
| NF C32-070, 2.2 | |
| UL 1685, 12 (FT4) | |
| according to ISO 6722-1 5.22 (UN ECE-R 118.01) | |
| Other resistances | Fuel resistant according to IRM 903, 168 h at 70 °C |
| Ambient Temperature (Service) | -25 °C ... 90 °C (Cable, movable arrangement) |
| -50 °C ... 120°C (cable, fixed arrangement) | |