Power cable, 5-position, PUR halogen-free, black-gray RAL 7021, Socket angled M12, K-coded, on free cable end, cable length: 10 m, for AC current up to 16 A/690 V Power cable, 5-pole halogen-free, free cable end, to Elbowed Female M12, coding: K, cable length: 10 m, for alternating current up to 16 A/690 V

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact SAC-5P-10,0-PUR/M12FRK PE power cable delivers safe electrical energy to heavy-duty actuators, drives, and decentralized control modules. These industrial power assemblies ensure continuous supply continuity in demanding manufacturing environments.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Type of electrical connection, box-sided (EF005524): M12
  • Type of plug-in contact, box-sided (EF008386): Female (bus)
  • Positioning cable feed, box-sided (EF005927): Angled
  • Cable length (EF000536): 10 m
  • Halogen free (EF000025): Yes
  • With LED indication (EF005950): No
  • Screened (EF000881): No
  • Vulcanize (EF004115): No
  • Rated voltage (EF000228): 690 V
  • Degree of protection (IP) (EF005474): IP65

More info

▲

Key Commercial Data

Orderkey1414817
Packing unit1 pc
Catalog pagePage 292 (C-2-2019)
GTIN4055626034508
Weight per Piece (excluding packing)1,760.000 g
Custom tariff number85444290
Country of originPL (Poland)

Drawings



Diagram

Dimensional drawing
M12 x 1 socket, angled



Circuit diagram
Contact assignment of the M12 socket

Schematic diagram
Pin assignment of M12 socket, 5-pos., K-coded, socket side view



Cable cross section
PUR halogen-free black [PUR]

Back to top

Dimensions

Length of cable10 m
Back to top

Ambient conditions

Ambient temperature (operation)-25 °C ... 85 °C (Plug / socket)
Degree of protectionIP65
IP67
Back to top

General

Rated current at 40°C16 A
Rated voltage690 V AC
Number of positions5
Color handle areablack
Insulation resistance≥ 100 MΩ
CodingK - Power
Standards/regulationsM12 connector IEC 61076-2-111
Status displayNo
Protective circuit/componentunwired
Overvoltage categoryIII
Degree of pollution3
Insertion/withdrawal cycles≥ 100
Torque0.4 Nm (M12 connector)
Back to top

Material

Flammability rating according to UL 94V0
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialPA
Material of grip bodyPP
Material, knurlsZinc die-cast, nickel-plated
Back to top

Standards and Regulations

Standards/specificationsM12 connector IEC 61076-2-111
Flammability rating according to UL 94V0
Back to top

Cable

Cable typePUR halogen-free black
Cable type (abbreviation)PUR
UL AWM style22078 / 11560 (90 °C / 1000 V)
Conductor cross section5x 2.5 mm²
AWG power supply14
Conductor structure, voltage supply141x 0.15 mm
Core diameter including insulation2.8 mm ±0.1 mm
Thickness, insulation≥ 0.36 mm
Wire colorsBlack 1, black 2, black 3, black 4, green/yellow
External sheath, colorblack-gray RAL 7021
Outer sheath thicknessapprox. 1.15 mm
External cable diameter D9.7 mm ±0,3 mm
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Number of bending cycles4000000
Minimum bending radius, drag chain applications10 x D
Traversing path10 m
Traversing rate3 m/s
Acceleration10 m/s²
Cable weight189 kg/km
Outer sheath, materialPUR
Material conductor insulationPP
Conductor materialBare Cu litz wires
Insulation resistance≥ 1 GΩ*km (at 20 °C)
Conductor resistance≤ 8 Ω/km (at 20 °C)
Nominal voltage, cable≤ 1000 V AC
Test voltage, cable≥ 10000 V AC (Spark test)
Flame resistanceAccording to UL 758/1581 (Cable Flame)
according to UL 758/1581 FT1
According to DIN EN 60332-1-2
Halogen-freein accordance with DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
Resistance to oilaccording to DIN EN 60811-404, 168 h at 100 °C
Other resistanceHydrolysis and microbe resistant as per VDE 0282 section 10
Low adhesion
abrasion-resistant
Resistant to salt water
Ambient temperature (operation)-50 °C ... 90 °C (cable, fixed installation)
-30 °C ... 90 °C (cable, flexible installation)
Back to top

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 4.024010400
eCl@ss 4.124010400
eCl@ss 5.019030300
eCl@ss 5.119030300
eCl@ss 6.027279200
eCl@ss 7.027279218
eCl@ss 8.027440203
eCl@ss 9.027440203
Back to top

ETIM

ETIM 3.0EC002061
ETIM 4.0EC001855
ETIM 5.0EC002311
ETIM 6.0EC002311
ETIM 7.0EC002311
Back to top

UNSPSC

UNSPSC 6.0131251501
UNSPSC 7.090131251501
UNSPSC 1131251501
UNSPSC 12.0131251501
UNSPSC 13.231251501
UNSPSC 18.027112301
UNSPSC 19.027112301
UNSPSC 20.027112301
UNSPSC 21.027112301
Back to top

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.