PHOENIX CONTACT SAC-4PY-FS-0,5-S03/2XF SH SR SAC-4PY-FS- 0,5-S03/2XF SH SR 1544305 PHOENIX CONTACT Y-Distributor, 4-pole, Female, to Straight Female M12,.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4PY-FS- 0,5-S03/2XF SH SR 1544305 PHOENIX CONTACT Y-Distributor, 4-pole, Female, to Straight Female M12,..

SAC-4PY-FS-0,5-S03/2XF SH SR

1544305

PHOENIX CONTACT

100 Pcs.

Y-Distributor, 4-pole, Female, to Straight Female M12, Encoding: A and Straight Female M12, Coding: A, Cable Length: 0.5 m Y-splitter, 4-pole halogen-free, Female, A Straight Female M12, coding: A and Straight Female M12, encoding: A, cable length: 0.5 m Y distributor, 4-position halogen-free, Socket, on Socket straight M12, coding: A and Socket straight M12, coding: A, cable length: 0.5 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact manufactures the SAC-4PY-FS-0,5-S03/2XF SH SR 1544305 Y-distributor to split or combine signals within industrial automation networks. Fieldbus and sensor systems utilize distributor components to branch signal lines efficiently without complex terminal re-wiring.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Product type: Distributor with cable
  • Number of positions: 4
  • No. of cable outlets: 1
  • Shielded: yes
  • Coding: A
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Flammability rating according to UL 94: HB
  • Seal material: NBR
  • Material of grip body: TPU, hardly inflammable, self-extinguishing
  • Contact material: CuSn
  • Contact surface material: Ni/Au
  • Contact carrier material: TPU GF
  • Material for screw connection: Zinc die-cast, nickel-plated
  • Contact resistance: ≤ 5 mΩ
  • Insulation resistance: ≥ 100 MΩ

More info

▲
Technical data

Product properties
Product typeDistributor with cable
Number of positions4
No. of cable outlets1
Shieldedyes
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94HB
Seal materialNBR
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties
Contact resistance≤ 5 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayNo
Status display presentNo

Connector
Connection 1
TypeSocket
Connection 2
TypeSocket straight M12
Coding typeA
Connection 3
TypeSocket straight M12
Coding typeA

Cable/line
Cable length0.5 m
Shielded black RADOX®[28R]
Dimensional drawing
Shieldedyes
Cable weight56 kg/km
Cable typeShielded black RADOX®
Cable type (abbreviation)28R
External cable diameter5.4 mm ±0.3 mm
Outer sheath, materialPE-X
External sheath, colorblack RAL 9005
Conductor materialTin-plated Cu litz wires
Conductor structure signal line19x 0.18 mm
AWG signal line20
Conductor cross section4x 0.5 mm²
Material wire insulationPE-X
Wire diameter incl. insulation1.43 mm
Single wire, colorwhite 1, white 2, white 3, white 4
Overall twist4 wires, twisted
ShieldingTinned copper braided shield
Optical shield covering85 %
Nominal voltage, cable600 V AC (Core-ground, U0)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, Um)
≤ 900 V DC (Core-ground, V0)
≤ 1500 V DC (Line-line)
Test voltage, cable3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
Cable resistance≤ 40.1 Ω/km
Minimum bending radius, fixed installation3 x D
Minimum bending radius, flexible installation4 x D
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Halogen-freein accordance with EN 50267-2-1
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Concentration of fumesBS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume toxicityBS 6853 B.1
EN 50305, 9.2
Fume corrosivenessEN 50267-2-2
Flame resistanceEN 60332-1-2
EN 50266
EN 50305, 9.1.2
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistanceResistance to fuels according to IRM 903, 168 h at 70 °C
Ambient temperature (operation)-25 °C ... 90 °C (Cable, flexible installation)
-50 °C ... 120 °C (cable, fixed installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)

Standards and regulations
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.