View larger
SAC-4P-M12MSS/4,0-PUR/FSSPESH 1423652 PHOENIX CONTACT Power cable
SAC-4P-M12MSS/4,0-PUR/FSSPESH
1423652
PHOENIX CONTACT
50 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact power cable (SAC-4P-M12MSS/4,0-PUR/FSSPESH) supplies electrical energy to heavy-duty drives, decentralized motor starters, and automation modules. Preassembled power distribution cables are regularly integrated into machine building to streamline high-voltage connections safely.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 4
- Type of electrical connection, field-sided (EF005525): M12
- Type of plug-in contact, field sided (EF006269): Male (plug)
- Positioning cable feed, field-sided (EF005928): Straight
- Type of electrical connection, box-sided (EF005524): M12
- Type of plug-in contact, box-sided (EF008386): Female (bus)
- Positioning cable feed, box-sided (EF005927): Straight
- Cable length (EF000536): 4 m
- Halogen free (EF000025): Yes
- With LED indication (EF005950): No
- Screened (EF000881): Yes
- Vulcanize (EF004115): No
- Rated voltage (EF000228): 690 V
- Degree of protection (IP) (EF005474): IP65
More info
▲Ambient conditions
| Ambient temperature (operation) | -25 °C ... 85 °C (Plug / socket) |
|---|---|
| Degree of protection | IP65 |
| IP67 |
General
| Rated current at 40°C | 12 A |
|---|---|
| Rated voltage | 690 V AC |
| Number of positions | 4 |
| Color handle area | black |
| Insulation resistance | ≥ 100 MΩ |
| Coding | S power |
| Standards/regulations | M12 connector IEC 61076-2-111 |
| Status display | No |
| Protective circuit/component | unwired |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Insertion/withdrawal cycles | > 100 |
| Torque | 0.4 Nm (M12 connector) |
Material
| Flammability rating according to UL 94 | V0 |
|---|---|
| Contact material | CuZn |
| Contact surface material | Ni/Au |
| Contact carrier material | PA |
| Material of grip body | PA |
| Material, knurls | Zinc die-cast, nickel-plated |
Standards and Regulations
| Standard designation | M12 connector |
|---|---|
| Standards/regulations | IEC 61076-2-111 |
| Flammability rating according to UL 94 | V0 |
Cable
| Cable type | PUR halogen-free orange shielded |
|---|---|
| Cable type (abbreviation) | PUR |
| Cable abbreviation | 9YSLC11Y-JZ |
| UL AWM style | 20234 / 10492 (80°C/1000 V) |
| Conductor cross section | 4x 1.5 mm² |
| AWG power supply | 16 |
| Conductor structure, voltage supply | 78x 0.15 mm |
| Core diameter including insulation | ≤ 2.5 mm |
| Thickness, insulation | 0.4 mm |
| Wire colors | Black 1, black 2, black 3, green/yellow |
| Overall twist | 4 wires optimally twisted |
| Shielding | Tinned copper-braided shield, approx. 85% covering |
| External sheath, color | orange RAL 2003 |
| Outer sheath thickness | 1.2 mm |
| External cable diameter D | 9.7 mm ±0,3 mm |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 7.5 x D |
| Number of bending cycles | 4000000 |
| Minimum bending radius, drag chain applications | 10 x D |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Torsion force | ± 25 °/m |
| Outer sheath, material | PUR |
| Material conductor insulation | PP |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 10 MΩ*km (at 20 °C) |
| Conductor resistance | ≤ 13.3 Ω/km (at 20 °C) |
| Nominal voltage, cable | 1000 V AC |
| Test voltage, cable | 4260 V AC (5 min.) |
| Flame resistance | according to EN 60332-1-2 |
| in acc. to UL 1581 VW1 | |
| According to CSA C 22.2 No. 210-05 FT1 | |
| Halogen-free | according to VDE 0282-13 Appendix C |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| According to DIN EN 50363-10-2 | |
| Other resistance | UV resistant |
| Low adhesion | |
| Ambient temperature (operation) | -40 °C ... 90 °C (cable, fixed installation) |
| -30 °C ... 90 °C (cable, flexible installation) |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |