View larger
SAC-4P-M12MSS/0,89-PUR/FRS PE 1555026 PHOENIX CONTACT Power cable, 4-pole, halogen-free PUR, grayish black R..
SAC-4P-M12MSS/0,89-PUR/FRS PE
1555026
PHOENIX CONTACT
50 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact SAC-4P-M12MSS/0,89-PUR/FRS PE power cable delivers safe electrical energy distribution to distributed drive systems, motors, and field power modules in industrial automation installations. Heavy-duty construction ensures dependable performance under demanding operational conditions.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product type: Power cable
- Number of positions: 4
- Application: Power supply
- No. of cable outlets: 1
- Shielded: no
- Coding: S
- Insulation characteristics Overvoltage category: III
- Degree of pollution: 3
- Flammability rating according to UL 94: V0
- Material of grip body: PP
- Contact material: CuZn
- Contact surface material: Ni/Au
- Contact carrier material: PA
- Material for screw connection: Zinc die-cast, nickel-plated
- Outer sheath, material: PUR
- Contact resistance: ≤ 5 mΩ
More info
▲| Trade restriction | |
| CE note | The products are offered exclusively for export outside the EU and the European Economic Area. |
| Product type | Power cable |
| Number of positions | 4 |
| Application | Power supply |
| No. of cable outlets | 1 |
| Shielded | no |
| Coding | S |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Flammability rating according to UL 94 | V0 |
| Material of grip body | PP |
| Contact material | CuZn |
| Contact surface material | Ni/Au |
| Contact carrier material | PA |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Outer sheath, material | PUR |
| Contact resistance | ≤ 5 mΩ |
| Insulation resistance | ≥ 100 MΩ |
| Nominal voltage UN | 690 V AC |
| Nominal current IN | 12 A |
| Protective circuit | unwired |
| Connection 1 | |
| Type | Plug straight M12 |
| Coding type | S (Power) |
| Connection 2 | |
| Type | Socket angled M12 |
| Coding type | S (Power) |
| Cable length | 0.89 m |
| PUR halogen-free black [PUR] | |
| Dimensional drawing | |
| Shielded | no |
| UL AWM Style | 20234 / 10492 (80°C/1000 V) |
| Cable weight | 114 kg/km |
| Cable type | PUR halogen-free black |
| Short symbol | Li9YV1-11Y |
| Cable type (abbreviation) | PUR |
| External cable diameter | 8.8 mm ±0.25 mm |
| Outer sheath, material | PUR |
| External sheath, color | black-gray RAL 7021 |
| Thickness, outer sheath | approx. 1.3 mm |
| Conductor material | Bare Cu litz wires |
| Conductor structure, voltage supply | 78x 0.15 mm |
| Conductor cross section | 4x 1.5 mm² |
| AWG power supply | 16 |
| Material wire insulation | PP |
| Thickness, insulation | ≥ 0.36 mm |
| Wire diameter incl. insulation | 2.45 mm ±0.05 mm |
| Single wire, color | black 1, black 2, black 3, green/yellow |
| Overall twist | 4 wires, twisted |
| Length of twist, overall twist | 93 mm |
| Nominal voltage, cable | ≤ 1000 V AC |
| Test voltage, cable | ≥ 10000 V AC (Spark test) |
| Cable resistance | ≤ 13 Ω/km (at 20 °C) |
| Cable insulation resistance | ≥ 1 GΩ*km (at 20 °C) |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Number of bending cycles | 2000000 |
| Minimum bending radius, drag chain applications | 10 x D |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| in accordance with DIN EN 50267-2-1 | |
| Resistance to oil | According to DIN EN 60811-2-1, 168 h at 100°C |
| According to UL 758, 168 h at 60°C | |
| Flame resistance | According to UL 758/1581 (Cable Flame) |
| according to UL 758/1581 FT1 | |
| According to DIN EN 60332-1-2 | |
| Other resistance | Hydrolysis and microbe resistant as per VDE 0282 section 10 |
| Low adhesion | |
| abrasion-resistant | |
| Resistant to salt water | |
| Ambient temperature (operation) | -30 °C ... 80 °C (Cable, flexible installation) |
| -50 °C ... 80 °C (cable, fixed installation) | |
| Ambient conditions | |
| Degree of protection | IP65 (without preloading, as additional test in accordance with IEC 60529) |
| IP67 (without preloading, as additional test in accordance with IEC 60529) | |
| Ambient temperature (operation) | -25 °C ... 85 °C (Plug / socket) |
| Standard designation | M12 connector |
| Standards/specifications | IEC 61076-2-111 |