View larger
SAC-4P-M12MSD/ 4,0-936/M12MSD 1401034 PHOENIX CONTACT Bus system cable
SAC-4P-M12MSD/ 4,0-936/M12MSD
1401034
PHOENIX CONTACT
50 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Optimized for high-speed industrial networks, this Phoenix Contact bus system cable ensures reliable data exchange between controllers and network nodes. Robust industrial communication cables prevent packet loss and maintain synchronization across automated systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1401034
- Packing unit: 1
- GTIN: 4046356517461
- Custom tariff number: 85444290
- Number of positions: 4
- Shielded: yes
- Insertion/withdrawal cycles: ≥ 100
- Cable diameter: 7.25 mm
- Length of cable: 4 m
- Degree of protection: IP65/IP67/IP69K
- No. of cable outlets: 1
- Ambient temperature (operation): -25 °C ... 90 °C (Plug / socket)
- Degree of protection: IP65
- Flammability rating according to UL 94: V0
- Contact carrier material: PA 6.6
- Contact material: CuSn
More info
▲Mechanical characteristics
| Number of positions | 4 |
|---|---|
| Shielded | yes |
| Insertion/withdrawal cycles | ≥ 100 |
| Cable diameter | 7.25 mm |
| Length of cable | 4 m |
| Degree of protection | IP65/IP67/IP69K |
| No. of cable outlets | 1 |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 90 °C (Plug / socket) |
|---|---|
| -40 °C ... 90 °C (cable, fixed installation) | |
| -25 °C ... 90 °C (cable, flexible installation) | |
| Degree of protection | IP65 |
| IP67 | |
| IP68 |
Material data
| Flammability rating according to UL 94 | V0 |
|---|---|
| Contact carrier material | PA 6.6 |
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Cable gland material | Zinc die-cast, nickel-plated |
| Sealing material | NBR |
| Outer sheath, material | PE-X |
| External sheath, color | black RAL 9005 |
Line characteristics
| Cable type | Ethernet |
|---|---|
| Cable structure | 1x4xAWG22/7; SF/TQ |
| Conductor cross section | 4x 0.34 mm² |
| AWG signal line | 22 |
| Conductor structure signal line | 7x 0.25 mm |
| Core diameter including insulation | 1.95 mm |
| External cable diameter | 7.25 mm ±0,3 mm |
| Wire colors | white-blue, orange-yellow |
| External sheath, color | black RAL 9005 |
| Transmission medium | Copper |
| Conductor resistance | ≤ 54.4 Ω/km |
| Working capacitance | ≤ 65 pF (core-core) |
| ≤ 100 pF (core-shield) | |
| Wave impedance | 100 Ω ±5 Ω (f = 100 MHz) |
| Near end crosstalk attenuation (NEXT) | 80 dB (with 1 MHz) |
| 76 dB (at 4 МHz) | |
| 67 dB (at 10 MHz) | |
| 60 dB (at 31.5 МHz) | |
| 56 dB (at 62.5 МHz) | |
| 53 dB (at 100 MHz) | |
| Wave attenuation | 2 dB (with 1 MHz) |
| 4 dB (at 4 МHz) | |
| 6.5 dB (at 10 MHz) | |
| 10.5 dB (at 31.5 МHz) | |
| 14 dB (at 62.5 МHz) | |
| 18 dB (at 100 MHz) | |
| Return Loss | 35 dB (at 4 МHz) |
| 35 dB (at 10 MHz) | |
| 35 dB (at 31.5 МHz) | |
| 33 dB (at 62.5 МHz) | |
| 33 dB (at 100 MHz) | |
| Signal speed | 66 c |
| Shield attenuation | 40 dB (30 MHz ≤ f ≤ 100 MHz) |
| Coupling resistance | 200.00 mΩ/m (f ≤ 30 MHz) |
| Nominal voltage, cable | 300 V AC |
| Test voltage, cable | 2000 V AC (50 Hz, 5 minutes) |
| Overall twist | Star quad |
| Shielding | Plastic-coated aluminum foil, tinned copper braided shield |
| Optical shield covering | 100 % |
| Outer sheath, material | PE-X |
| Material conductor insulation | PE-X |
| Conductor material | silver-plated Cu litz wires |
| Cable weight | 81 g/m |
| Minimum bending radius, fixed installation | 6 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Flame resistance | EN 60332-1-2 |
| EN 50266 | |
| EN 60332-3-25 | |
| NF C32-070, 2.1 | |
| NF C32-070, 2.2 | |
| UL 1685, 12 (FT4) | |
| in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) | |
| Halogen-free | According to EN 50267-2-1 |
| Resistance to oil | according to IRM 902, 72 h at 100 °C |
| Other resistance | Resistance to fuels according to IRM 903, 168 h at 70 °C |
| Ambient temperature (operation) | -50 °C ... 90 °C (cable, fixed installation) |
| -40 °C ... 90 °C (cable, flexible installation) |