PHOENIX CONTACT SAC-4P-M12MSB/3-920/M12FSB X2X SAC-4P-M12MSB/3-920/M12FSB X2X 1416299 PHOENIX CONTACT Bus system cable SAC-4P-M12MSB/3-920/M12FSB X2X 14162.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4P-M12MSB/3-920/M12FSB X2X 1416299 PHOENIX CONTACT Bus system cable SAC-4P-M12MSB/3-920/M12FSB X2X 14162..

SAC-4P-M12MSB/3-920/M12FSB X2X

1416299

PHOENIX CONTACT

50 Pcs.

Bus system cable - SAC-4P-M12MSB/3-920/M12FSB X2X - 1416299 Bus system cable, 4-pole, halogen-free PUR, violet RAL 4001, shielded, M12 straight male connector, coding: B-coded, M12 straight connection female a, coding: B-coded, cable length: 3 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Industrial networks and automation controllers require robust wiring infrastructure, such as the SAC-4P-M12MSB/3-920/M12FSB X2X 1416299 PHOENIX CONTACT Bus system cable. Fieldbus assemblies are deployed across industrial plants to link distributed input and output modules to central control architectures. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Orderkey: 1416299
  • Packing unit: 1
  • GTIN: 4055626067636
  • Custom tariff number: 85444290
  • Length of cable: 3 m
  • Rated current at 40°C: 4 A
  • Rated voltage: 48 V AC
  • Number of positions: 4
  • Insulation resistance: ≥ 100 MΩ
  • Coding: B-coded
  • Status display: No
  • Overvoltage category: II
  • Degree of pollution: 3
  • Insertion/withdrawal cycles: ≥ 100
  • Flammability rating according to UL 94: HB
  • Contact material: CuSn

More info

▲

Bus system cable, 4-position, PUR halogen-free, violet RAL 4001, shielded, Plug straight M12, B-coded, on Socket straight M12, B-coded, cable length: 3 m

Key Commercial Data

Orderkey1416299
Packing unit1
GTIN4055626067636
Custom tariff number85444290

Dimensions

Length of cable3 m

General

Rated current at 40°C4 A
Rated voltage48 V AC
60 V DC
Number of positions4
Insulation resistance≥ 100 MΩ
CodingB-coded
Status displayNo
Overvoltage categoryII
Degree of pollution3
Insertion/withdrawal cycles≥ 100

Material

Flammability rating according to UL 94HB
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Material, knurlsZinc die-cast, nickel-plated
Sealing materialNBR

Standards and Regulations

Flammability rating according to UL 94HB

Cable

Cable typeCAN Bus/DeviceNet
Cable type (abbreviation)920
UL AWM style21198 (80°C/300 V)
Cable structure2xAWG24/19+2xAWG22/19
Conductor cross section2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
AWG signal line24
AWG power supply22
Conductor structure signal line19x 0.13 mm
Conductor structure, voltage supply19x 0.15 mm
Core diameter including insulation1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
Wire colorsRed-black, blue-white
Twisted pairs2 cores to the pair
Type of pair shieldingPlastic-coated aluminum foil, aluminum side outside
Overall twist2 pairs around a drain wire in the center to the core
ShieldingTinned copper braided shield
Optical shield covering80 %
External sheath, colorviolet RAL 4001
External cable diameter D6.7 mm ±0,3 mm
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Number of bending cycles5000000
Bending radius70 mm
Minimum bending radius, drag chain applications10 x D
Traversing path4.5 m
Traversing rate3 m/s
Acceleration3 m/s²
Cable weight90 kg/km
Outer sheath, materialPUR
Material conductor insulationFoamed PE (Data cable)
PE (Power supply)
Conductor materialTin-plated Cu litz wires
Insulation resistance≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Loop resistance≤ 181.80 Ω/km (Data cable)
≤ 114.80 Ω/km (Power supply)
Cable capacitynom. 40 nF/km (Data cable)
Wave impedance120 Ω ±10 % (with 1 MHz)
Attenuation≤ 22.9 dB/km (with 1 MHz)
≤ 16.4 dB/km (At 500 kHz)
≤ 9.5 dB/km (At 125 kHz)
Nominal voltage, cable≤ 300 V (Peak value, not for high-power applications)
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000 V (50 Hz, 1 min.)
Flame resistanceUL 1581, Sec. 1060 (FT-1)
IEC 60332-1
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-freein accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Other resistanceLow adhesion
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

eCl@ss

eCl@ss 5.127060300
eCl@ss 6.027279200
eCl@ss 7.027279218
eCl@ss 8.027279218
eCl@ss 9.027060311

ETIM

ETIM 5.0EC001855
ETIM 6.0EC001855
ETIM 7.0EC001855

UNSPSC

UNSPSC 13.231251501

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.