PHOENIX CONTACT SAC-4P-M12MS/40-28X/M12FSSHOD SAC-4P-M12MS/40-28X/M12FSSHOD 1419637 PHOENIX CONTACT Sensor/actuator cable SAC-4P-M12MS/40-28X/M12FSSHOD 14.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4P-M12MS/40-28X/M12FSSHOD 1419637 PHOENIX CONTACT Sensor/actuator cable SAC-4P-M12MS/40-28X/M12FSSHOD 14..

SAC-4P-M12MS/40-28X/M12FSSHOD

1419637

PHOENIX CONTACT

10 Pcs.

Sensor/actuator cable - SAC-4P-M12MS/40-28X/M12FSSHOD - 1419637 Cable for sensors/actuators Sensor/actuator cable, 4-position, PE-X/PE-X halogen-free, black-gray RAL 7021, shielded, Plug straight M12, coding: A, on Socket straight M12, coding: A, cable length: 40 m, for outdoor applications, with high-grade steel knurl

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact sensor/actuator cable delivers dependable connectivity for industrial control components, linking sensors and actuators directly to input/output modules. Such cabling is essential for routing control signals safely across modern automated machinery.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Sensor/actuator cable
  • Application: External areas
  • Number of positions: 4
  • No. of cable outlets: 1
  • Shielded: yes
  • Coding: A
  • Insulation characteristics Degree of pollution: 3
  • Flammability rating according to UL 94: V0
  • Seal material: FPM
  • Material of grip body: PP
  • Contact material: CuSn
  • Contact surface material: Ni/Au
  • Contact carrier material: PP
  • Material for screw connection: Stainless steel
  • Insulation resistance: ≥ 100 MΩ
  • Nominal voltage U N: 48 V AC

More info

▲
Technical data

Product properties
Product typeSensor/actuator cable
ApplicationExternal areas
Number of positions4
No. of cable outlets1
Shieldedyes
CodingA
Insulation characteristics
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Seal materialFPM
Material of grip bodyPP
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialPP
Material for screw connectionStainless steel

Electrical properties
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayno
Status display presentNo

Connector
Connection 1
TypePlug straight M12
Number of positions4
Coding typeA
Connection 2
TypeSocket straight M12
Number of positions4
Coding typeA

Cable/line
Cable length40 m
PE-X black [28X]
Dimensional drawing
Cable weight74 kg/km
Number of positions4
Shieldedyes
Cable typePE-X black [28X]
Conductor structure signal line28x 0.15 mm
AWG signal line20
Conductor cross section4x 0.5 mm² (Signal line)
Wire diameter incl. insulation1.6 mm ±0.05 mm (Signal line)
External cable diameter6.80 mm ±0.2 mm
Outer sheath, materialPE-X
External sheath, colorblack-gray RAL 7021
Conductor materialBare Cu litz wires
Material wire insulationPE-X
Single wire, colorbrown, white, blue, black
Thickness, insulationapprox. 0.30 mm (Core insulation)
approx. 0.70 mm (Outer cable sheath)
approx. 0.45 mm (Inner sheath)
Overall twist4 wires, twisted
Length of twist, overall twist108.8 mm
Optical shield covering85 %
Max. conductor resistance≤ 39 Ω/km (at 20 °C)
Insulation resistance≥ 100 MΩ*km (at 20 °C)
Cable capacity≤ 100 nF/km (Conductor-conductor, asymmetrical/touching)
≤ 85 nF/km (Conductor-conductor, symmetrical/star quad)
≤ 150 nF/km (Wire/shield)
Nominal voltage, cable≤ 300 V AC
Test voltage≥ 3000 V AC
Smallest bending radius, fixed installation34 mm
Smallest bending radius, movable installation68 mm
Dynamic load capacity (bending)Max. bending cycles: 1000000, Bending radius: 68 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s²
Halogen-freein accordance with DIN VDE 0472 part 815
Flame resistanceaccording to DIN 60332-1-2
according to DIN EN 50266-2-5
Resistance to oilin accordance with DIN EN 60811-2-1
Other resistanceUV resistant (according to DIN VDE 0276-605)
Special propertiesIrradiated
Ambient temperature (operation)-40 °C ... 105 °C (cable, fixed installation)
-15 °C ... 105 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP68
Ambient temperature (operation)-40 °C ... 105 °C (Plug / socket)
-40 °C ... 85 °C (On sudden changes in temperature (according to IEC 60512-11-4))

Standards and regulations
M12
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.