View larger
SAC-4P-M12MR/0,6PURM12FSSHBKPF 1563889 PHOENIX CONTACT Sensor/actuator cable
SAC-4P-M12MR/0,6PURM12FSSHBKPF
1563889
PHOENIX CONTACT
50 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Phoenix Contact SAC-4P-M12MR/0,6PURM12FSSHBKPF sensor/actuator cable serves as an interconnection link for automated industrial machinery, tying together distributed field devices. Signal and data cables of this type maintain the communication pathways vital for modern industrial processes. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1563889
- Packing unit: 1 pc
- Minimum order quantity: 50 pc
- Note: Made to Order (non-returnable)
- GTIN: 4046356304061
- Weight per Piece (excluding packing): 58.200 g
- Custom tariff number: 85444290
- Country of origin: PL (Poland)
- Length of cable: 0.6 m
- Degree of protection: IP65
- Rated current at 40°C: 4 A
- Rated voltage: 48 V AC
- Number of positions: 4
- Insulation resistance: ≥ 100 MΩ
- Coding: A - standard
- Status display: No
More info
▲Key Commercial Data
| Orderkey | 1563889 |
|---|---|
| Packing unit | 1 pc |
| Minimum order quantity | 50 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4046356304061 |
| Weight per Piece (excluding packing) | 58.200 g |
| Custom tariff number | 85444290 |
| Country of origin | PL (Poland) |
General
| Rated current at 40°C | 4 A |
|---|---|
| Rated voltage | 48 V AC |
| 60 V DC | |
| Number of positions | 4 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | A - standard |
| Status display | No |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Insertion/withdrawal cycles | ≥ 100 |
Material
| Flammability rating according to UL 94 | HB |
|---|---|
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Contact carrier material | TPU GF |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Material, knurls | Zinc die-cast, nickel-plated |
| Sealing material | NBR |
Cable
| Cable type | PUR halogen-free black |
|---|---|
| Cable type (abbreviation) | PUR |
| Cable abbreviation | Li9Y-V1-C-V1-11Y |
| UL AWM style | 20549 / 10493 (80°C/300 V) |
| Conductor cross section | 4x 0.34 mm² (Signal line) |
| AWG signal line | 22 |
| Conductor structure signal line | 42x 0.10 mm |
| Core diameter including insulation | 1.27 mm ±0.02 mm (Signal line) |
| Thickness, insulation | ≥ 0.21 mm |
| Wire colors | brown, white, blue, black |
| Overall twist | 4 wires, twisted |
| Shielding | Tinned copper braided shield |
| Optical shield covering | 80 % |
| External sheath, color | black-gray RAL 7021 |
| Outer sheath thickness | approx. 0.5 mm |
| External cable diameter D | 4.95 mm ±0.2 mm |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Number of bending cycles | 10000000 |
| Minimum bending radius, drag chain applications | 10 x D |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Cable weight | 36 kg/km |
| Outer sheath, material | PUR |
| Material conductor insulation | PP |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 100 GΩ*km (at 20 °C) |
| Conductor resistance | max. 58 Ω/km (at 20 °C) |
| Cable capacity | ≤ 80 pF/m (Conductor-Conductor) |
| ≤ 135 pF/m (Wire/shield) | |
| Wave impedance | ≥ 62 Ω (f = 10 MHz) |
| Conductor inductance | approx. 0.75 mH/km (f = 1 kHz) |
| Nominal voltage, cable | ≤ 300 V |
| Test voltage, cable | ≥ 3000 V |
| Special properties | Flexible cable conduit capable |
| Silicone-free | |
| Free of substances which would hinder coating with paint or varnish | |
| Low adhesion surface | |
| Flame resistance | in accordance with UL 758/1581 FT2 |
| DIN EN 60332-2-2 (20 s) | |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| in accordance with DIN EN 50267-2-1 | |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| hydrolysis and microbe resistant | |
| Resistant to salt water | |
| partly UV-resistant in accordance with DIN EN ISO 4892-2-A | |
| abrasion-resistant | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| -25 °C ... 80 °C (cable, flexible installation) |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |