Sensor/Actuator Cable, 4-Pole, Halogen-Free, PE-X/PE-X, Grey-Black RAL 7021, Free Cable End, to Straight Female M12, Coding: A, Outdoor Application, Knurled Stainless Steel Sensor/Actuator Cable, 4-Pole, Halogen-Free PE-X/PE-X, Greyish Black RAL 7021, Free Cable End, to M12 Straight Connection Female, Coded: A, for Outdoor Applications, with Stainless Steel Knurling Sensor/actuator cable, 4-position, free cable end, on Socket straight M12, coding: A, for outdoor applications, with high-grade steel knurl

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Designed for demanding outdoor conditions, the Phoenix Contact SAC-4P-65,0-28X/M12FS SH OD sensor/actuator cable provides reliable signal transmission for exposed industrial environments. Field cabling solutions like this maintain signal integrity and mechanical protection where moisture and temperature variations are present.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Product type: Sensor/actuator cable
  • Number of positions: 4
  • Application: External areas
  • No. of cable outlets: 1
  • Coding: A
  • Insulation characteristics Degree of pollution: 3
  • Flammability rating according to UL 94: V0
  • Seal material: FPM
  • Material of grip body: PP
  • Contact material: CuSn
  • Contact surface material: Ni/Au
  • Contact carrier material: PP
  • Material for screw connection: Stainless steel
  • Contact resistance: ≤ 5 mΩ
  • Insulation resistance: ≥ 100 MΩ
  • Nominal voltage U N: 48 V AC

More info

▲
Technical data

Product properties
Product typeSensor/actuator cable
Number of positions4
ApplicationExternal areas
No. of cable outlets1
CodingA
Insulation characteristics
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Seal materialFPM
Material of grip bodyPP
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialPP
Material for screw connectionStainless steel

Electrical properties
Contact resistance≤ 5 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A
Protective circuitunwired

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayNo
Status display presentNo

Connector
Connection 1
Typefree cable end
Connection 2
TypeSocket straight M12
Number of positions4
Coding typeA

Cable/line
PE-X black [28X]
Dimensional drawing
Shieldedyes
Cable weight74 kg/km
Cable typePE-X black
Short symbolLi2X2X-C-Vl-2X
Cable type (abbreviation)28X
External cable diameter6.8 mm ±0.2 mm
Outer sheath, materialPE-X
External sheath, colorblack-gray RAL 7021
Material, inner sheathPE-X
Conductor materialBare Cu litz wires
Conductor structure signal line28x 0.15 mm
AWG signal line20
Conductor cross section4x 0.5 mm² (Signal line)
Material wire insulationPE-X
Thickness, insulationapprox. 0.3 mm (Core insulation)
Wire diameter incl. insulation1.6 mm ±0.05 mm (Signal line)
Single wire, colorbrown, white, blue, black
Overall twist4 wires, twisted
Length of twist, overall twist108.8 mm
ShieldingBraided copper wires
Optical shield covering85 %
Nominal voltage, cable≤ 300 V AC
Test voltage, cable≥ 3000 V AC
Cable resistance≤ 39 Ω/km (at 20 °C)
Cable insulation resistance≥ 100 MΩ*km (at 20 °C)
Cable capacity≤ 100 nF/km (Conductor-conductor, asymmetrical/touching)
≤ 85 nF/km (Conductor-conductor, symmetrical/star quad)
≤ 150 nF/km (Wire/shield)
Conductor inductance0.64 mH/km (at 1 kHz)
0.46 mH/km (at 10 MHz)
Smallest bending radius, fixed installation34 mm
Smallest bending radius, movable installation68 mm
Number of bending cycles1000000
Bending radius68 mm
Traversing path10 m
Traversing rate3 m/s
Acceleration10 m/s²
Halogen-freein accordance with DIN VDE 0472 part 815
Resistance to oilin accordance with DIN EN 60811-2-1
Flame resistanceaccording to DIN 60332-1-2
according to DIN EN 50266-2-5
Other resistanceUV resistant according to DIN VDE 0276-605
Special propertiesIrradiated
Ambient temperature (operation)-15 °C ... 105 °C (Cable, flexible installation)
-40 °C ... 105 °C (cable, fixed installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
IP68
IP69K
Ambient temperature (operation)-40 °C ... 105 °C (Plug / socket)
-40 °C ... 85 °C (On sudden changes in temperature (according to IEC 60512-11-4))

Standards and regulations
M12
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.