View larger
SAC-4P- 5,0-PUR/P12FR SH 1476838 PHOENIX CONTACT Sensor/actuator cable, 4-pole, halogen-free PUR, greyish bl..
SAC-4P-5,0-PUR/P12FR SH
1476838
PHOENIX CONTACT
1 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact SAC-4P- 5,0-PUR/P12FR SH sensor/actuator cable provides shielded signal transfer for automated industrial installations. Protected wiring assemblies prevent electromagnetic interference from disrupting critical control communications.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Link: Push-Pull
- Product Type: Sensor/Actuator Cable
- No. of poles: 4
- Application: Standard
- Number of cable outlets: 1
- Shielded: Yes
- Coding: at
- Insulation characteristics Overvoltage Category: II
- Degree of pollution: 3
- Combustibility class according to UL 94: V0
- Outer Sheath, Material: WHILE
- Conductor material: Bare Cu Wire
- Mass Resistivity: ≤ 5 mΩ
- Insulation Resistance: ≥ 100 MΩ
- Rated voltage U N: 48 V AC
- Rated Current I N: 4 A
More info
▲| Link | Push-Pull |
| Product Type | Sensor/Actuator Cable |
| No. of poles | 4 |
| Application | Standard |
| Number of cable outlets | 1 |
| Shielded | Yes |
| Coding | at |
| Insulation characteristics | |
| Overvoltage Category | II |
| Degree of pollution | 3 |
| Combustibility class according to UL 94 | V0 |
| Outer Sheath, Material | WHILE |
| Conductor material | Bare Cu Wire |
| Mass Resistivity | ≤ 5 mΩ |
| Insulation Resistance | ≥ 100 MΩ |
| Rated voltage UN | 48 V AC |
| 60 V DC | |
| Rated Current IN | 4 A |
| Protection Circuit | without circuit |
| Conductor resistance max. | 58 Ω/km |
| Mechanical data | |
| Manoeuvring cycles | ≥ 100 |
| Bending cycles, maximum | 10000000 |
| Status Reporting | no |
| Available Status Indication | no |
| Connection technology | |
| Link | Push-Pull |
| Conductor connection | |
| Link | Push-Pull |
| Connection 1 | |
| type | Free conductor end |
| Connection 2 | |
| type | M12 Push-Pull Angled Receptacle |
| Clamping Type | Push-Pull |
| Encoding Type | at |
| Cable Length | 4 L |
| Halogenated free PUR black [PUR] | |
| Dimensioned Drawing | |
| Line Weight | 36 kg/km |
| UL AWM Style | 20549 / 10493 (80 °C / 300 V) |
| No. of poles | 4 |
| Shielded | Yes |
| Cable Type | Halogenated free PUR black [PUR] |
| Line Signal Conductor Structure | 42x 0.10 mm |
| AWG Signal Line | 22 |
| Conductor cross-section | 4x 0.34 mm² (Signal line) |
| Wire diameter with insulating sheath | 1.27 mm ±0.02 mm (Signal line) |
| Conductor Outer Diameter | 4.95 mm ±0.2 mm |
| Outer Sheath, Material | WHILE |
| Outer sheath, color | grey-black RAL 7021 |
| Conductor material | Bare Cu Wire |
| Material, Wire Insulation | PP |
| Single conductor, color | brown, white, blue, black |
| Insulation wall thickness | ≥ 0.21 mm |
| Outer sheath wall thickness | ca. 0.5 mm |
| Full stranding | 4 longitudinally twisted wires |
| Optical Shielded Cover | 80 % |
| Conductor resistance max. | max. 58 Ω/km (at 20 °C) |
| Insulation Resistance | ≥ 100 GΩ*km (at 20 °C) |
| Characteristic Impedance | ≥ 62 Ω (f = 10 MHz) |
| Line Capacity | ≤ 80 pF/m (Conductor-to-Conductor) |
| ≤ 135 pF/m (Conductor shielding) | |
| Nominal cable voltage | ≤ 300 V |
| Test voltage | ≥ 3000 V |
| Minimum bending radius, fixed | 5 x D |
| Minimum bending radius, flexible | 10 x D |
| Minimum bending radius, fixed | 25 mm |
| Minimum bending radius, movable | 50 mm |
| Bending cycles, maximum | 10000000 |
| Halogen-free | according to DIN VDE 0472 Part 815 |
| in accordance with DIN EN 50267-2-1 | |
| Flame Resistance | according to UL 758/1581 FT2 |
| DIN EN 60332-2-2 (20 s) | |
| Oil Resistance | in accordance with DIN EN 60811-2-1 |
| Other Resistance | Very good resistance against acids, lyes and solvents |
| Resistance to hydrolysis and microbes | |
| Seawater resistant | |
| UV-resistant according to DIN EN ISO 4892-2-A | |
| abrasion resistant | |
| Special features | for energy chains |
| silicone-free | |
| No impregnated varnish substances | |
| Non-adherent surface | |
| Ambient temperature (operating) | -40 °C ... 80 °C (cables, fixed installation) |
| -25 °C ... 80 °C (Cables, movable installation) | |
| Environmental conditions | |
| Degree of protection | IP65 |
| IP67 | |
| Ambient temperature (operating) | -25 °C ... 85 °C (connector / female connector) |
| -40 °C ... 80 °C (cables, fixed installation) | |
| -25 °C ... 80 °C (Cables, movable installation) | |
| Standard Definition | M12-Push-Pull |
| Standards/Regulations | IEC 61076-2-010 |