Sensor/actuator cable Sensor/Actuator Cable, 4-pole, Halogen-free PE-X, black, free cable end, to M12 SPEEDCON straight connection female, coding: A, cable length: 2.5 m, For railway applications

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The SAC-4P-2,5-731/FS SCO RAIL 1022352 PHOENIX CONTACT Sensor/actuator cable is a specialized sensor/actuator cable designed for reliable signal transmission in demanding industrial automation setups. Factory-assembled cabling links field devices like sensors and actuators securely to control systems, ensuring consistent data and power communication across machinery.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Number of poles (EF001391): 4
  • Type of electrical connection, box-sided (EF005524): M12
  • Type of plug-in contact, box-sided (EF008386): Female (bus)
  • Positioning cable feed, box-sided (EF005927): Straight
  • Cable length (EF000536): 2.5 m
  • Halogen free (EF000025): Yes
  • Colour cable sheath (EF008248): Black
  • With LED indication (EF005950): No
  • Screened (EF000881): No
  • Cable type (EF000081): Multi-core
  • Vulcanize (EF004115): No
  • Material contact body (EF008248): CuSn
  • Rated voltage (EF000228): 48 V
  • Degree of protection (IP) (EF005474): IP65

More info

▲

Key Commercial Data

Orderkey1022352
Packing unit1
GTIN4055626516509
Custom tariff number85444290

Dimensions

Length of cable2.5 m
Stripping length of the free conductor end100 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C (Plug / socket)

General

Rated voltage48 V AC
60 V DC
Number of positions4
Insulation resistance≥ 100 MΩ
CodingA - standard
Standards/regulationsM12 connector IEC 61076-2-101
Shock, vibration EN 50155
Status displayNo
Protective circuit/componentunwired
Overvoltage categoryII
Degree of pollution3
Insertion/withdrawal cycles≥ 100
Product labelingArt.-Nr. 1022352 2,5m 731 4x0,5 H+S 12568038 KW/JJ (Phoenix Contact cable printing)
HUBER+SUHNER RADOX TENUIS- TW 600V 4X0,5 MM 12568038-[Prod.- Nr.] [Herstelldatum] [Prod.- Ort] (Cable printing cable supplier)

Material

Flammability rating according to UL 94V0
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material of grip bodyPA 6.6
Material, knurlsZinc die-cast, nickel-plated
Sealing materialNBR

Standards and Regulations

Standard designationM12 connector
Standards/regulationsIEC 61076-2-101
Standard designationShock, vibration
Standards/regulationsEN 50155
Flammability rating according to UL 94V0

Cable

Cable typeRADOX®black
Cable type (abbreviation)731
Conductor cross section4x 0.5 mm²
AWG signal line20
Conductor structure signal line19x 0.18 mm
Core diameter including insulation1.43 mm
Wire colorsWhite 1, white 2, white 3, white 4
Overall twist4 wires, twisted
External sheath, colorblack
External cable diameter D5 mm ±0.2 mm
Minimum bending radius, fixed installation3 x D
Minimum bending radius, flexible installation4 x D
Cable weight43 kg/km
Outer sheath, materialPE-X
Material conductor insulationPE-X
Conductor materialTin-plated Cu litz wires
Conductor resistance≤ 40.1 Ω/km
Nominal voltage, cable600 V AC (Core-ground, U0)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, Um)
≤ 900 V DC (Core-ground, V0)
≤ 1500 V DC (core-core)
Test voltage, cable3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F1)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistanceEN 60332-1-2
EN 50266
EN 50305, 9.1.2
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-freeAccording to EN 50267-2-1
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Other resistanceResistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumesBS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume corrosivenessEN 50267-2-2
Fume toxicityBS 6853 B.1
EN 50305, 9.2
Ambient temperature (operation)-50 °C ... 120 °C (cable, fixed installation)
-25 °C ... 90 °C (cable, flexible installation)

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.