View larger
SAC-4P- 2,0-731/M 8FS 1424064 PHOENIX CONTACT Sensor/actuator cable SAC-4P- 2,0-731/M 8FS 1424064
SAC-4P-2,0-731/M 8FS
1424064
PHOENIX CONTACT
50 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Phoenix Contact SAC-4P-2,0-731/M 8FS sensor/actuator cable creates dependable electrical connections between compact automation field devices and control junction blocks. Engineers utilize these pre-wired cable assemblies to simplify wiring layouts in modern automated machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles: 4
- Type of electrical connection, box-sided: M8
- Type of plug-in contact, box-sided: Female (bus)
- Positioning cable feed, box-sided: Straight
- Cable length: 2 m
- Halogen free: Yes
- Colour cable sheath: Black
- With LED indication: No
- Screened: No
- Cable type: Multi-core
- Vulcanize: No
- Material contact body: CuSn
- Rated current In: 4 A
- Rated voltage: 48 V
- Degree of protection (IP): IP65
More info
▲Sensor/actuator cable, 4-position, PE-X halogen-free, black, free cable end, on Socket straight M8, cable length: 2 m, Customer version
Key Commercial Data
| Orderkey | 1424064 |
|---|---|
| Packing unit | 1 |
| GTIN | 4055626367262 |
| Custom tariff number | 85444290 |
Dimensions
| Length of cable | 2 m |
|---|---|
| Stripping length of the free conductor end | 20 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 90 °C (Plug / socket) |
|---|
General
| Rated current at 40°C | 4 A |
|---|---|
| Rated voltage | 48 V AC |
| 60 V DC | |
| Number of positions | 4 |
| Insulation resistance | 100 MΩ |
| Coding | A - standard |
| Standards/regulations | M8 connector IEC 61076-2-104 |
| Status display | No |
| Protective circuit/component | unwired |
| Overvoltage category | II |
| Degree of pollution | 3 |
Material
| Flammability rating according to UL 94 | HB |
|---|---|
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Contact carrier material | TPU GF |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Material, knurls | Zinc die-cast, nickel-plated |
| Sealing material | NBR |
Pin assignment
| Contact | Color (signal designation) | Contact (optional) | 1 (M8 socket) | WH1 |
|---|---|
| 2 (M8 socket) | WH2 | |
| 3 (M8 socket) | WH3 | |
| 4 (M8 socket) | WH4 |
Standards and Regulations
| Standard designation | M8 connector |
|---|---|
| Standards/regulations | IEC 61076-2-104 |
| Flammability rating according to UL 94 | HB |
Cable
| Cable type | RADOX®black |
|---|---|
| Cable type (abbreviation) | 731 |
| Conductor cross section | 4x 0.5 mm² |
| AWG signal line | 20 |
| Conductor structure signal line | 19x 0.18 mm |
| Core diameter including insulation | 1.43 mm |
| Wire colors | White 1, white 2, white 3, white 4 |
| Overall twist | 4 wires, twisted |
| External sheath, color | black |
| External cable diameter D | 5 mm ±0.2 mm |
| Minimum bending radius, fixed installation | 3 x D |
| Minimum bending radius, flexible installation | 4 x D |
| Cable weight | 43 kg/km |
| Outer sheath, material | PE-X |
| Material conductor insulation | PE-X |
| Conductor material | Tin-plated Cu litz wires |
| Conductor resistance | ≤ 40.1 Ω/km |
| Nominal voltage, cable | 600 V AC (Core-ground, U0) |
| 1000 V AC (Core-ground, U) | |
| ≤ 720 V AC (core-ground) | |
| ≤ 1200 V AC (Core-ground, Um) | |
| ≤ 900 V DC (Core-ground, V0) | |
| ≤ 1500 V DC (core-core) | |
| Test voltage, cable | 3500 V AC (50 Hz, 5 min.) |
| 8400 V DC (50 Hz, 5 min.) | |
| Fire protection in rail vehicles | BS 6853 (Category Ia, Ib, II) |
| GM/RT 2130 (Category Ia, Ib, II) | |
| EN 45545 (Risk level HL1 - HL3) | |
| DIN 5510 (Fire protection level 1, 2, 3, 4) | |
| NF F16-101 (Category A1, A2, B) | |
| NF F16-101 (Class C/F1) | |
| NFPA 130 | |
| UNI CEI 11170 (Risk level LR1 - LR4) | |
| Flame resistance | EN 60332-1-2 |
| EN 50266 | |
| EN 50305, 9.1.2 | |
| NF C32-070, 2.1 | |
| NF C32-070, 2.2 | |
| UL 1685, 12 (FT4) | |
| in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) | |
| Halogen-free | According to EN 50267-2-1 |
| Resistance to oil | according to IRM 902, 72 h at 100 °C |
| Other resistance | Resistance to fuels according to IRM 903, 168 h at 70 °C |
| Concentration of fumes | BS 6853 D.8.7 |
| EN 61034-2 | |
| UL 1685, 12 (FT4) | |
| Fume corrosiveness | EN 50267-2-2 |
| Fume toxicity | BS 6853 B.1 |
| EN 50305, 9.2 | |
| Ambient temperature (operation) | -50 °C ... 120 °C (cable, fixed installation) |
| -25 °C ... 90 °C (cable, flexible installation) |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |
Classifications
eCl@ss
| eCl@ss 6.0 | 27279200 |
|---|---|
| eCl@ss 7.0 | 27279218 |
| eCl@ss 9.0 | 27060311 |
ETIM
| ETIM 5.0 | EC001855 |
|---|---|
| ETIM 6.0 | EC001855 |
| ETIM 7.0 | EC001855 |