PHOENIX CONTACT SAC-4P-1,5-PUR/P12FS SAC-4P- 1,5-PUR/P12FS 1392839 PHOENIX CONTACT Sensor/actuator cable, 4-pole, halogen-free PUR, greyish black.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4P- 1,5-PUR/P12FS 1392839 PHOENIX CONTACT Sensor/actuator cable, 4-pole, halogen-free PUR, greyish black..

SAC-4P-1,5-PUR/P12FS

1392839

PHOENIX CONTACT

1 Pcs.

Sensor/actuator cable, 4-pole, halogen-free PUR, greyish black RAL 7021, free cable end, to Straight female M12 Push-pull, coding: A, cable length: 1.5 m Sensor/Actuator Cable, 4-Pole, Halogen-Free PUR, Greyish Black RAL 7021, Free Cable End, A Straight Connection Female M12 Push-Pull, Encoding: A, Cable Length: 1.5 m Sensor/actuator cable, 4-position halogen-free, free cable end, on Socket straight M12 Push Pull, coding: A, cable length: 1.5 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

This Phoenix Contact sensor/actuator cable provides dependable connectivity for standard industrial automation setups, linking monitoring devices to control systems. Pre-assembled wiring solutions minimize downtime and maintain signal integrity in industrial applications.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Product type: Sensor/actuator cable
  • Number of positions: 4
  • Application: Standard
  • No. of cable outlets: 1
  • Shielded: no
  • Coding: A
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Material: PA
  • Flammability rating according to UL 94: V0
  • Seal material: FKM
  • Material of grip body: TPU, hardly inflammable, self-extinguishing
  • Contact material: CuSn
  • Contact surface material: Ni/Au
  • Material for screw connection: Brass, nickel-plated
  • Insulation resistance: ≥ 100 MΩ

More info

▲
Technical data

Product properties
Product typeSensor/actuator cable
Number of positions4
ApplicationStandard
No. of cable outlets1
Shieldedno
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
MaterialPA
Flammability rating according to UL 94V0
Seal materialFKM
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuSn
Contact surface materialNi/Au
Material for screw connectionBrass, nickel-plated

Electrical properties
Insulation resistance≥ 100 MΩ
Nominal voltage UN250 V AC
250 V DC
Nominal current IN4 A
Protective circuitunwired

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayNo
Status display presentNo

Connection data
Conductor connection
Tightening torqueM12 push-pull connectors

Connector
Connection 1
Typefree cable end
Connection 2
TypeSocket straight M12 Push Pull
Number of positions4
Locking typePush Pull
Coding typeA

Cable/line
Cable length1.5 m
PUR halogen-free black [PUR]
Dimensional drawing
Cable weight30 kg/km
UL AWM Style20549 / 10493 (80°C/300 V)
Number of positions4
Shieldedno
Cable typePUR halogen-free black [PUR]
Conductor structure signal line42x 0.10 mm
AWG signal line22
Conductor cross section4x 0.34 mm² (Signal line)
Wire diameter incl. insulation1.27 mm ±0.02 mm
External cable diameter4.2 mm ±0.15 mm
Outer sheath, materialPUR
External sheath, colorblack-gray RAL 7021
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorbrown, white, blue, black
Thickness, insulation≥ 0.21 mm
Thickness, outer sheathapprox. 0.5 mm
Overall twist4 wires, twisted
Max. conductor resistance≤ 58 Ω/km
Insulation resistance≥ 1 GΩ*km
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation21 mm
Smallest bending radius, movable installation42 mm
Max. bending cycles10000000
Halogen-freein accordance with DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
Flame resistancein accordance with UL 758/1581 FT2
DIN EN 60332-2-2 (20 s)
Resistance to oilin accordance with DIN EN 60811-2-1
Other resistanceHighly resistant to acids, alkaline solutions and solvents
hydrolysis and microbe resistant
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Low adhesion
abrasion-resistant
Special propertiesFlexible cable conduit capable
Silicone-free
Free of substances which would hinder coating with paint or varnish
flexible
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
Ambient temperature (operation)-25 °C ... 85 °C (Plug / socket)

Standards and regulations
Standard designationM12-Push-Pull
Standards/specificationsIEC 61076-2-010

Product Datasheet