View larger
SAC-4P-10,0-280/M12FR-2L 1441228 PHOENIX CONTACT Cable for sensors/actuators, 4-pole, PUR, silver-gray RAL 7..
SAC-4P-10,0-280/M12FR-2L
1441228
PHOENIX CONTACT
1 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact SAC-4P-10,0-280/M12FR-2L 1441228 PHOENIX CONTACT Cable for sensors/actuators, 4-pole, PUR, silver-gray RAL 7.. acts as a flexible connection lead for integrating field sensors and control components. Factory automation systems deploy these assemblies to facilitate secure signal transfer across expansive machinery layouts. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Key order: One million four hundred forty one thousand two hundred twenty eight
- Packing unit: 1 pcs
- Key selling: BF1CCA -
- Unit weight (excluding packaging): 317,000 g
- Tariff number tariff: Eighty five million four hundred forty four thousand two hundred ninety
- Country of origin: PL (Poland)
- Cable length: 10 m
- Tension sizing: 24 V DC
- Number of poles: Four
- Status indication: 2 LEDs
- Cycles of plug: ≥ 100
- Type of cable: PUR halogen-free, grey
- Cable type (abbreviation): Two hundred eighty
- Abbreviation of cable: Li9Y11Y
- Section of driver: 0,34 mm2
- Signal cable AWG: Twenty two
More info
▲Cable for sensors/actuators, 4-pole, PUR halogen-free, gray RAL 7001, end of free cable, to connection socket angled M12, cable length: 10 m
Data commercial
| Key order | One million four hundred forty one thousand two hundred twenty eight |
|---|---|
| Packing unit | 1 pcs |
| Key selling | BF1CCA - |
| EAN | Four trillion forty six billion three hundred fifty six million five hundred sixteen thousand one hundred twenty nine |
| Unit weight (excluding packaging) | 317,000 g |
| Tariff number tariff | Eighty five million four hundred forty four thousand two hundred ninety |
| Country of origin | PL (Poland) |
Measures
| Cable length | 10 m |
|---|
Overview
| Tension sizing | 24 V DC |
|---|---|
| Number of poles | Four |
| Status indication | 2 LEDs |
| Cycles of plug | ≥ 100 |
Cable
| Type of cable | PUR halogen-free, grey |
|---|---|
| Cable type (abbreviation) | Two hundred eighty |
| Abbreviation of cable | Li9Y11Y |
| Section of driver | 0,34 mm2 |
| Signal cable AWG | Twenty two |
| Construction of the driver signal cable | 42x 0.10 mm |
| Diameter of the conductors, insulation included | 1.27 mm ±0.02 mm |
| Thickness of wall Insulation | ≥ 0.21 mm (Insulated conductor) |
| approx. 0.8 mm (outer Wrap) | |
| Colors driver | Brown, white, blue, black |
| Cabling total | 4-conductor longitudinally twisted |
| Step of wiring total | 49,5 mm |
| Outer wrap, color | grey RAL 7001 |
| Outer diameter of cable D | 4.7 mm ±0.15 mm |
| Smallest bending radius, fixed mounting | 23.5 mm |
| Smaller bending radius, mobile mounting | 47 mm |
| Number of bending cycles | Four million |
| Bending radius | 47 mm |
| Journey forward | 10 m |
| Forward speed | 3 m/s |
| Acceleration | 10 m/s2 |
| Weight of the cable | 30 kg/km |
| Outer casing, material | PUR |
| Material Insulation conductor | PP |
| Conductive Material | Conductor Cu bare |
| Insulation resistance | ≥ 100 MΩ*km |
| Resistance of the conductor | max. 58 Ω/km (at 20 °C) |
| Rated voltage Cable | ≤ 300 V |
| Test voltage Cable | ≥ 3000 V |
| Special features | suitable for drag chain |
| without silicone | |
| without any substances disturbing the wettability paintings | |
| Flame resistance | according to UL-Style 20549 |
| in accordance with FT1 according to UL 758 | |
| Absence of halogen | according to DIN VDE 0472 part 815 |
| according to DIN en 50267-2-1 | |
| Oil resistance | according to DIN en 60811-2-1 |
| Other resistors | good resistance to acids, alkalis and solvents |
| resistant to hydrolysis and microbes | |
| Room temperature (service) | -40 °C ... 80 °C (cable, fixed) |
| -25 °C ... 80 °C (cable, available mobile) |
Ratings
eCl@ss
| eCl@ss 4.0 | Twenty seven million sixty thousand three hundred six |
|---|---|
| eCl@ss 4.1 | Twenty seven million sixty thousand three hundred six |
| eCl@ss 5.0 | Twenty seven million sixty one thousand eight hundred one |
| eCl@ss 5.1 | Twenty seven million sixty one thousand eight hundred |
| eCl@ss 6.0 | Twenty seven million two hundred seventy nine thousand two hundred |
| eCl@ss 7.0 | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 8.0 | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 9.0 | Twenty seven million sixty thousand three hundred eleven |
ETIM
| ETIM 3.0 | EC001855 |
|---|---|
| ETIM 4.0 | EC001855 |
| ETIM 5.0 | EC001855 |
| ETIM 6.0 | EC001855 |
| ETIM 7.0 | EC001855 |
UNSPSC
| UNSPSC 6.01 | Thirty one million two hundred fifty one thousand five hundred one |
|---|---|
| UNSPSC 7.0901 | Thirty one million two hundred fifty one thousand five hundred one |
| UNSPSC 11 | Thirty one million two hundred fifty one thousand five hundred one |
| UNSPSC 12.01 | Thirty one million two hundred fifty one thousand five hundred one |
| UNSPSC 13.2 | Thirty one million two hundred fifty one thousand five hundred one |