PHOENIX CONTACT SAC-3P-MS/18,7-28R/MS2+3NCRAIL SAC-3P-MS/18,7-28R/MS2+3NCRAIL 1048896 PHOENIX CONTACT Cable for sensors/actuators, 3-pole, PE-X halogen-fre.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-3P-MS/18,7-28R/MS2+3NCRAIL 1048896 PHOENIX CONTACT Cable for sensors/actuators, 3-pole, PE-X halogen-fre..

SAC-3P-MS/18,7-28R/MS2+3NCRAIL

1048896

PHOENIX CONTACT

1 Pcs.

Cable for sensors/actuators, 3-pole, PE-X halogen-free, black, shielded, Plug straight M12 SPEEDCON, coded, to male Connector straight M12 SPEEDCON, coded, cable length: 18,7 m, For railway applications Sensor/actuator cable, 3-pole, halogen-free PE-X, black, shielded, M12 SPEEDCON straight male connector, coding: A, a M12 SPEEDCON straight male connector, coding: A, cable length: 18.7 m, For railway applications Sensor/actuator cable, 3-position, PE-X halogen-free, black, shielded, Plug straight M12 SPEEDCON, coding: A, on Plug straight M12 SPEEDCON, coding: A, cable length: 18.7 m, For railway applications

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact cable for sensors/actuators, identified as part number SAC-3P-MS/18,7-28R/MS2+3NCRAIL, facilitates heavy-duty signal routing between industrial controllers and peripheral equipment. Railway and demanding industrial applications use specialized halogen-free Radox cabling to withstand harsh thermal and mechanical conditions. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Sensor/actuator cable
  • Number of positions: 3
  • Nominal voltage U N: 48 V AC
  • Connection 1 Type: Plug straight M12 SPEEDCON
  • Number of positions: 3
  • Locking type: SPEEDCON
  • Coding type: A
  • Connection 2 Type: Plug straight M12 SPEEDCON
  • Number of positions: 3
  • Locking type: SPEEDCON
  • Coding type: A
  • Cable length: 18.7 m
  • Cable weight: 51 kg/km
  • Number of positions: 3
  • Shielded: yes
  • Cable type: Shielded black RADOX® [28R]

More info

▲
Technical data

Product properties
Product typeSensor/actuator cable
Number of positions3

Electrical properties
Nominal voltage UN48 V AC
60 V DC

Connector
Connection 1
TypePlug straight M12 SPEEDCON
Number of positions3
Locking typeSPEEDCON
Coding typeA
Connection 2
TypePlug straight M12 SPEEDCON
Number of positions3
Locking typeSPEEDCON
Coding typeA

Cable/line
Cable length18.7 m
Shielded black RADOX® [28R]
Dimensional drawing
Cable weight51 kg/km
Number of positions3
Shieldedyes
Cable typeShielded black RADOX® [28R]
Conductor structure signal line19x 0.18 mm
AWG signal line20
Conductor cross section3x 0.5 mm²
Wire diameter incl. insulation1.43 mm
External cable diameter5.30 mm ±0.3 mm
Outer sheath, materialPE-X
External sheath, colorblack
Conductor materialTin-plated Cu litz wires
Material wire insulationPE-X
Single wire, colorwhite 1, white 2, white 3
Overall twist3 wires, twisted
Max. conductor resistance≤ 40.1 Ω/km
Nominal voltage, cable600 V AC (Core-ground, U0)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, Um)
≤ 900 V DC (Core-ground, V0)
≤ 1500 V DC (Line-line)
Test voltage3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
Minimum bending radius, fixed installation3 x D
Minimum bending radius, flexible installation4 x D
Smallest bending radius, fixed installation16 mm
Smallest bending radius, movable installation22 mm
Halogen-freein accordance with EN 50267-2-1
Flame resistanceEN 60332-1-2
EN 50266
EN 50305, 9.1.2
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Fume corrosivenessEN 50267-2-2
Fume toxicityBS 6853 B.1
EN 50305, 9.2
Concentration of fumesBS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Other resistanceResistance to fuels (according to IRM 903, 168 h at 70 °C)
Ambient temperature (operation)-50 °C ... 120 °C (cable, fixed installation)
-25 °C ... 90 °C (Cable, flexible installation)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.