PHOENIX CONTACT SAC-3P-M12Y/2X0,45-PUR/M12FS SAC-3P-M12Y/2X0,45-PUR/M12FS 1630373 PHOENIX CONTACT Sensor/actuator cable, 3-pole, halogen-free PUR, greyis.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-3P-M12Y/2X0,45-PUR/M12FS 1630373 PHOENIX CONTACT Sensor/actuator cable, 3-pole, halogen-free PUR, greyis..

SAC-3P-M12Y/2X0,45-PUR/M12FS

1630373

PHOENIX CONTACT

50 Pcs.

Sensor/actuator cable, 3-pole, halogen-free PUR, greyish black RAL 7021, Straight connector M12, coding: A, to Straight female M12, coding: A and Straight female M12, coding: A, cable length: 0.45 m Cable for sensors/actuators Sensor/actuator cable, 3-position, Plug straight M12, coding: A, on Socket straight M12, coding: A and Socket straight M12, coding: A, cable length: 0.45 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact SAC-3P-M12Y/2X0,45-PUR/M12FS sensor/actuator cable acts as a multi-port splitter assembly to branch a single automation line into two distinct peripheral connections. This style of Y-distributor optimizes wiring layouts by reducing the total number of physical ports required on active junction blocks.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Product type: Distributor with cable
  • Number of positions: 3
  • No. of cable outlets: 2
  • Shielded: no
  • Coding: A
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Flammability rating according to UL 94: HB
  • Seal material: NBR
  • Material of grip body: TPU, hardly inflammable, self-extinguishing
  • Contact material: CuSn
  • Contact surface material: Ni/Au
  • Contact carrier material: TPU GF
  • Material for screw connection: Zinc die-cast, nickel-plated
  • Contact resistance: ≤ 5 mΩ
  • Insulation resistance: ≥ 10 GΩ

More info

▲
Technical data

Product properties
Product typeDistributor with cable
Number of positions3
No. of cable outlets2
Shieldedno
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Connection data
Pin assignment
Contact | Color (signal designation) | Contact (optional)1 (Plug) | BN | 4 (Socket 1)
1 (Plug) | BN | 3 (Socket 2)
3 (Plug) | BU | 3 (Socket 1)
4 (Plug) | BK | 4 (Socket 2)

Material specifications
Flammability rating according to UL 94HB
Seal materialNBR
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties
Contact resistance≤ 5 mΩ
Insulation resistance≥ 10 GΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayNo
Status display presentNo

Connector
Connection 1
TypePlug straight M12
Coding typeA
Connection 2
TypeSocket straight M12
Coding typeA
Connection 3
TypeSocket straight M12
Coding typeA

Cable/line
Cable length0.45 m
PUR halogen-free black [PUR]
Dimensional drawing
Shieldedno
UL AWM Style20549
Cable weight23 kg/km
Cable typePUR halogen-free black
Short symbolLi9Y11Y
Cable type (abbreviation)PUR
External cable diameter3.85 mm ±0.15 mm
Outer sheath, materialPUR
External sheath, colorblack-gray RAL 7021
Conductor materialBare Cu litz wires
Conductor structure signal line42x 0.10 mm
AWG signal line22
Conductor cross section3x 0.34 mm² (Signal line)
Material wire insulationPP
Thickness, insulation≥ 0.21 mm (Core insulation)
Wire diameter incl. insulation1.27 mm ±0.02 mm (Signal line)
Single wire, colorbrown, blue, black
Overall twist3 wires, twisted
Nominal voltage, cable≤ 300 V
Test voltage, cable≥ 3000 V
Cable resistancemax. 58 Ω/km (at 20 °C)
Cable insulation resistance≥ 100 GΩ*km (at 20 °C)
Smallest bending radius, fixed installation19 mm
Smallest bending radius, movable installation38 mm
Number of bending cycles10000000
Bending radius38 mm
Traversing path10 m
Traversing rate3 m/s
Acceleration10 m/s²
Halogen-freein accordance with DIN VDE 0472 part 815
Resistance to oilin accordance with DIN EN 60811-2-1
Flame resistancein accordance with UL 758/1581 FT2
DIN EN 60332-2-2 (20 s)
Other resistanceHighly resistant to acids, alkaline solutions and solvents
hydrolysis and microbe resistant
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Special propertiesFlexible cable conduit capable
Silicone-free
Free of substances which would hinder coating with paint or varnish
Ambient temperature (operation)-25 °C ... 80 °C (Cable, flexible installation)
-40 °C ... 80 °C (cable, fixed installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP68
Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
-40 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (Cable, flexible installation)

Product Datasheet