View larger
SAC-3P-M12MR/1,5-PUR/M12FR-2LB 1668690 PHOENIX CONTACT Sensor/actuator cable
SAC-3P-M12MR/1,5-PUR/M12FR-2LB
1668690
PHOENIX CONTACT
50 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact sensor/actuator cable, identified as SAC-3P-M12MR/1,5-PUR/M12FR-2LB 1668690, is designed for signal routing in industrial automation systems. Pre-wired connection cords ensure stable electrical pathways between field instrumentation and control systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1668690
- Packing unit: 5 pc
- Minimum order quantity: 25 pc
- Note: Made to Order (non-returnable)
- GTIN: 4017918137144
- Weight per Piece (excluding packing): 63.160 g
- Custom tariff number: 85444290
- Country of origin: PL (Poland)
- Length of cable: 1.5 m
- Ambient temperature (operation): -25 °C ... 90 °C (Plug / socket)
- Degree of protection: IP65
- Rated current at 40°C: 4 A
- Rated voltage: 24 V
- Number of positions: 3
- Insulation resistance: ≥ 100 MΩ
- Coding: A - standard
More info
▲Key Commercial Data
| Orderkey | 1668690 |
|---|---|
| Packing unit | 5 pc |
| Minimum order quantity | 25 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4017918137144 |
| Weight per Piece (excluding packing) | 63.160 g |
| Custom tariff number | 85444290 |
| Country of origin | PL (Poland) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 90 °C (Plug / socket) |
|---|---|
| Degree of protection | IP65 |
| IP67 | |
| IP68 |
General
| Rated current at 40°C | 4 A |
|---|---|
| Rated voltage | 24 V |
| 24 V DC | |
| Number of positions | 3 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | A - standard |
| Status display | 2 LEDs |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Insertion/withdrawal cycles | ≥ 100 |
Material
| Flammability rating according to UL 94 | HB |
|---|---|
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Contact carrier material | TPU GF |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Material, knurls | Zinc die-cast, nickel-plated |
| Sealing material | NBR |
Cable
| Cable type | PUR halogen-free black |
|---|---|
| Cable type (abbreviation) | PUR |
| Cable abbreviation | Li9Y11Y |
| UL AWM style | 20549 |
| Conductor cross section | 3x 0.34 mm² (Signal line) |
| AWG signal line | 22 |
| Conductor structure signal line | 42x 0.10 mm |
| Core diameter including insulation | 1.27 mm ±0.02 mm (Signal line) |
| Thickness, insulation | ≥ 0.21 mm (Core insulation) |
| approx. 0.5 mm (Outer cable sheath) | |
| Wire colors | brown, blue, black |
| Overall twist | 3 wires, twisted |
| External sheath, color | black-gray RAL 7021 |
| External cable diameter D | 3.85 mm ±0.15 mm |
| Smallest bending radius, fixed installation | 19 mm |
| Smallest bending radius, movable installation | 38 mm |
| Number of bending cycles | 10000000 |
| Bending radius | 44 mm |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Cable weight | 23 kg/km |
| Outer sheath, material | PUR |
| Material conductor insulation | PP |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 100 GΩ*km (at 20 °C) |
| Conductor resistance | max. 58 Ω/km (at 20 °C) |
| Nominal voltage, cable | ≤ 300 V |
| Test voltage, cable | ≥ 3000 V |
| Special properties | Flexible cable conduit capable |
| Silicone-free | |
| Free of substances which would hinder coating with paint or varnish | |
| Flame resistance | in accordance with UL 758/1581 FT2 |
| DIN EN 60332-2-2 (20 s) | |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| hydrolysis and microbe resistant | |
| partly UV-resistant in accordance with DIN EN ISO 4892-2-A | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| -25 °C ... 80 °C (cable, flexible installation) |