View larger
SAC-3P-M12MR/0,3-PUR/M12FS 1071521 PHOENIX CONTACT Sensor/actuator cable SAC-3P-M12MR/0,3-PUR/M12FS 1071521
SAC-3P-M12MR/0,3-PUR/M12FS
1071521
PHOENIX CONTACT
50 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A short-run Phoenix Contact sensor/actuator cable, part number SAC-3P-M12MR/0,3-PUR/M12FS, provides compact interconnection for closely spaced industrial components. Short jumper cables prevent clutter in dense junction boxes while ensuring reliable signal continuity. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1071521
- Packing unit: 1
- GTIN: 4055626761985
- Custom tariff number: 85444290
- Length of cable: 0.3 m
- Degree of protection: IP65
- Rated current at 40°C: 4 A
- Rated voltage: 250 V AC
- Number of positions: 3
- Insulation resistance: ≥ 100 MΩ
- Coding: A - standard
- Standards/regulations: M12 connector IEC 61076-2-101
- Status display: No
- Protective circuit/component: unwired
- Overvoltage category: II
- Degree of pollution: 3
More info
▲Sensor/actuator cable, 3-position, PUR halogen-free, black-gray RAL 7021, cable length: 0.3 m
Key Commercial Data
| Orderkey | 1071521 |
|---|---|
| Packing unit | 1 |
| GTIN | 4055626761985 |
| Custom tariff number | 85444290 |
Dimensions
| Length of cable | 0.3 m |
|---|
Ambient conditions
| Degree of protection | IP65 |
|---|---|
| IP67 |
General
| Rated current at 40°C | 4 A |
|---|---|
| Rated voltage | 250 V AC |
| 250 V DC | |
| Number of positions | 3 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | A - standard |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Status display | No |
| Protective circuit/component | unwired |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Torque | 0.4 Nm |
Material
| Flammability rating according to UL 94 | HB |
|---|---|
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Contact carrier material | TPU GF |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Material, knurls | Zinc die-cast, nickel-plated |
| Sealing material | NBR |
Standards and Regulations
| Standard designation | M12 connector |
|---|---|
| Standards/regulations | IEC 61076-2-101 |
| Flammability rating according to UL 94 | HB |
Cable
| Cable type | PUR halogen-free black |
|---|---|
| Cable type (abbreviation) | PUR |
| Cable abbreviation | Li9Y11Y |
| UL AWM style | 20549 |
| Conductor cross section | 3x 0.34 mm² (Signal line) |
| AWG signal line | 22 |
| Conductor structure signal line | 42x 0.10 mm |
| Core diameter including insulation | 1.27 mm ±0.02 mm (Signal line) |
| Thickness, insulation | ≥ 0.21 mm (Core insulation) |
| approx. 0.5 mm (Outer cable sheath) | |
| Wire colors | brown, blue, black |
| Overall twist | 3 wires, twisted |
| External sheath, color | black-gray RAL 7021 |
| External cable diameter D | 3.85 mm ±0.15 mm |
| Smallest bending radius, fixed installation | 19 mm |
| Smallest bending radius, movable installation | 38 mm |
| Number of bending cycles | 10000000 |
| Bending radius | 44 mm |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Cable weight | 23 kg/km |
| Outer sheath, material | PUR |
| Material conductor insulation | PP |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 100 GΩ*km (at 20 °C) |
| Conductor resistance | max. 58 Ω/km (at 20 °C) |
| Nominal voltage, cable | ≤ 300 V |
| Test voltage, cable | ≥ 3000 V |
| Special properties | Flexible cable conduit capable |
| Silicone-free | |
| Free of substances which would hinder coating with paint or varnish | |
| Flame resistance | in accordance with UL 758/1581 FT2 |
| DIN EN 60332-2-2 (20 s) | |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| hydrolysis and microbe resistant | |
| partly UV-resistant in accordance with DIN EN ISO 4892-2-A | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| -25 °C ... 80 °C (cable, flexible installation) |
Classifications
eCl@ss
| eCl@ss 4.0 | 27060306 |
|---|---|
| eCl@ss 4.1 | 27060306 |
| eCl@ss 5.0 | 27061801 |
| eCl@ss 5.1 | 27061801 |
| eCl@ss 6.0 | 27279200 |
| eCl@ss 7.0 | 27279218 |
| eCl@ss 8.0 | 27279218 |
| eCl@ss 9.0 | 27060311 |
ETIM
| ETIM 2.0 | EC000830 |
|---|---|
| ETIM 3.0 | EC001855 |
| ETIM 4.0 | EC001855 |
| ETIM 5.0 | EC001855 |
| ETIM 6.0 | EC001855 |
| ETIM 7.0 | EC001855 |
UNSPSC
| UNSPSC 6.01 | 31251501 |
|---|---|
| UNSPSC 7.0901 | 31251501 |
| UNSPSC 11 | 31251501 |
| UNSPSC 12.01 | 31251501 |
| UNSPSC 13.2 | 31251501 |