PHOENIX CONTACT SAC-2P-7,0-PUR/DTFS SAC-2P- 7,0-PUR/DTFS 1025856 PHOENIX CONTACT Sensor/actuator cable SAC-2P- 7,0-PUR/DTFS 1025856 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-2P- 7,0-PUR/DTFS 1025856 PHOENIX CONTACT Sensor/actuator cable SAC-2P- 7,0-PUR/DTFS 1025856

SAC-2P-7,0-PUR/DTFS

1025856

PHOENIX CONTACT

100 Pcs.

Sensor/actuator cable - SAC-2P- 7,0-PUR/DTFS - 1025856 Sensor/actuator cable, 2-pole, halogen-free PUR, greyish black RAL 7021, free cable end, to Straight connection female DEUTSCH DT06-2S Clip lock, cable length: 7 m Sensor/actuator cable, 2-position, PUR halogen-free, black-gray RAL 7021, free cable end, on Socket straight DEUTSCH DT06-2S Clip locking, coding: A, cable length: 7 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact sensor/actuator cable, part number SAC-2P-7,0-PUR/DTFS 1025856, offers robust signal transmission for industrial machinery requiring secure clip-locking connections. Halogen-free construction ensures safety and durability in demanding manufacturing environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Sensor/actuator cable
  • Number of positions: 2
  • Material of grip body: TPU
  • Connection 1 Type: free cable end
  • Connection 2 Type: Socket straight DEUTSCH DT06-2S Clip locking
  • Number of positions: 2
  • Locking type: Clip locking
  • Coding type: A
  • Cable length: 7 m
  • Cable weight: 33 kg/km
  • UL AWM Style: 20549 / 10493 (80°C/300 V)
  • Number of positions: 2
  • Shielded: no
  • Cable type: PUR halogen-free black [PUR]
  • Conductor structure signal line: 42x 0.15 mm
  • AWG signal line: 18

More info

▲
Technical data

Product properties
Product typeSensor/actuator cable
Number of positions2

Material specifications
Material of grip bodyTPU

Connector
Connection 1
Typefree cable end
Connection 2
TypeSocket straight DEUTSCH DT06-2S Clip locking
Number of positions2
Locking typeClip locking
Coding typeA

Cable/line
Cable length7 m
PUR halogen-free black [PUR]
Dimensional drawing
Cable weight33 kg/km
UL AWM Style20549 / 10493 (80°C/300 V)
Number of positions2
Shieldedno
Cable typePUR halogen-free black [PUR]
Conductor structure signal line42x 0.15 mm
AWG signal line18
Conductor cross section2x 0.75 mm² (Signal line)
Wire diameter incl. insulation1.69 mm ±0.05 mm (Signal line)
External cable diameter4.80 mm ±0.15 mm
Outer sheath, materialPUR
External sheath, colorblack-gray RAL 7021
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorbrown, blue
Thickness, insulation≥ 0.21 mm
Thickness, outer sheath≥ 0.38 mm
Overall twist2 wires, twisted
Max. conductor resistance≤ 26 Ω/km (at 20 °C)
Insulation resistance≥ 1 GΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V AC
Test voltage≥ 3000 V AC (Spark test)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation24 mm
Smallest bending radius, movable installation48 mm
Dynamic load capacity (bending)Max. bending cycles: 4000000, Bending radius: 48 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s²
Halogen-freein accordance with DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
Flame resistanceaccording to UL 758/1581 (horizontal)
in accordance with UL 758/1581 FT2
according to DIN EN 60332-2-2
Resistance to oilAccording to DIN EN 60811-2-1, 168 h at 100°C
according to UL 758, 168 h at 60 °C
Other resistancehydrolysis and microbe resistant
partly UV-resistant (in accordance with DIN EN ISO 4892-2-A)
Low adhesion
abrasion-resistant
Special propertiesflexible
Flexible cable conduit capable
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (Cable, flexible installation)