View larger
SAC-17P-MS/1,5-35T/FR SH SCO 1098952 PHOENIX CONTACT Sensor/actuator cable, 17-position, PUR/PVC, black RAL ..
SAC-17P-MS/1,5-35T/FR SH SCO
1098952
PHOENIX CONTACT
50 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact sensor/actuator cable (part number SAC-17P-MS/1,5-35T/FR SH SCO) is used to interconnect industrial automation devices, transmitting control signals and power safely between field instruments and controllers. These multi-core cabling assemblies provide reliable links in complex machinery setups.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 17
- Type of electrical connection, field-sided (EF005525): M12
- Type of plug-in contact, field sided (EF006269): Male (plug)
- Positioning cable feed, field-sided (EF005928): Straight
- Type of electrical connection, box-sided (EF005524): M12
- Type of plug-in contact, box-sided (EF008386): Female (bus)
- Positioning cable feed, box-sided (EF005927): Angled
- Cable length (EF000536): 1.5 m
- Halogen free (EF000025): Yes
- With LED indication (EF005950): No
- Screened (EF000881): Yes
- Cable type (EF000081): Multi-core
- Vulcanize (EF004115): No
- Material contact body (EF008248): CuZn
- Rated current In (EF008250): 1.5 A
- Rated voltage (EF000228): 30 V
More info
▲General
| Rated current at 40°C | 1.5 A |
|---|---|
| Rated voltage | 30 V AC |
| 30 V DC | |
| Number of positions | 17 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | A - standard |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Status display | No |
| Protective circuit/component | unwired |
| Overvoltage category | II |
| Degree of pollution | 3 |
Material
| Flammability rating according to UL 94 | V0 |
|---|---|
| Contact material | CuZn |
| Contact surface material | Ni/Au |
| Contact carrier material | PA 6.6 |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Material, knurls | Zinc die-cast, nickel-plated |
| Sealing material | NBR |
Standards and Regulations
| Standards/specifications | M12 connector IEC 61076-2-101 |
|---|---|
| Flame resistance | DIN VDE 0472 part 804, test type B |
| Resistance to oil | DIN VDE 0472 Part 803, test type B |
| Other resistance | Hydrolysis and microbe resistant as per VDE 0282 section 10 |
| Flammability rating according to UL 94 | V0 |
Cable
| Cable type | Black PUR/PVC twisted pair |
|---|---|
| Cable type (abbreviation) | 35T |
| Cable abbreviation | LSYWC11Y |
| UL AWM style | 20233 / 1061 (80°C/300 V) |
| Conductor cross section | 17x 0.14 mm² (Signal line) |
| AWG signal line | 26 |
| Conductor structure signal line | 18x 0.10 mm |
| Core diameter including insulation | 1 mm ±0.05 mm (Signal line) |
| Wire colors | White-brown, green-yellow, gray-pink, blue-red, black-violet, gray/pink-red/blue, white/green-brown/green, white/yellow-yellow/brown-white/gray |
| Overall twist | 7 pairs and 1 three-way unit, intertwisted |
| Shielding | Tinned copper braided shield |
| Optical shield covering | 85 % |
| External sheath, color | black RAL 9005 |
| External cable diameter D | 9.2 mm ±0.2 mm |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Number of bending cycles | 4000000 |
| Bending radius | 92 mm |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Cable weight | 105 kg/km |
| Outer sheath, material | PUR |
| Material, inner sheath | PVC |
| Material conductor insulation | PVC |
| Conductor material | Tin-plated Cu litz wires |
| Insulation resistance | ≥ 10 MΩ*km (at 20 °C) |
| Conductor resistance | 142 Ω/km (at 20 °C) |
| Nominal voltage, cable | 42 V AC |
| Test voltage, cable | 1500 V AC |
| Special properties | Flexible cable conduit capable |
| Flame resistance | According to DIN EN 60332-1-2 |
| According to VW-1 | |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Other resistance | hydrolysis and microbe resistant according to EN 50396 |
| Ambient temperature (operation) | -30 °C ... 80 °C (cable, fixed installation) |
| -5 °C ... 80 °C (cable, flexible installation) |