PHOENIX CONTACT SAC-17P-MS/0,2-35T/FS SH SCO SAC-17P-MS/0,2-35T/FS SH SCO 1522844 PHOENIX CONTACT Sensor/actuator cable, 17 poles, PUR/PVC, black RAL 900.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-17P-MS/0,2-35T/FS SH SCO 1522844 PHOENIX CONTACT Sensor/actuator cable, 17 poles, PUR/PVC, black RAL 900..

SAC-17P-MS/0,2-35T/FS SH SCO

1522844

PHOENIX CONTACT

25 Pcs.

Sensor/actuator cable, 17 poles, PUR/PVC, black RAL 9005, shielded, straight male connector SPEEDCON M12, coded A, in straight female connector, M12-SPEEDCON, cable length: 5 m Cable for sensors/actuators Sensor/actuator cable, 17-pos., PUR/PVC, RAL 9005 (black), shielded, straight M12 SPEEDCON male plug (A-coded) to straight M12 SPEEDCON female plug, cable length: 5 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact SAC-17P-MS/0,2-35T/FS SH SCO sensor/actuator cable provides high-density signal distribution for complex multi-pin industrial devices and automated systems. Multipole cordsets simplify wiring layouts by routing numerous data and control lines through a single interface.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Sensor/actuator cable
  • Number of positions: 17
  • Application: Standard
  • No. of cable outlets: 1
  • Shielded: yes
  • Coding: A
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Flammability rating according to UL 94: V0
  • Material of grip body: TPU, hardly inflammable, self-extinguishing
  • Contact material: CuZn
  • Contact surface material: Ni/Au
  • Contact carrier material: PA 6.6
  • Material for screw connection: Zinc die-cast, nickel-plated
  • Contact resistance: 0.005 MΩ
  • Nominal voltage U N: 30 V AC

More info

▲
Technical data

Product properties
Product typeSensor/actuator cable
Number of positions17
ApplicationStandard
No. of cable outlets1
Shieldedyes
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties
Contact resistance0.005 MΩ
Nominal voltage UN30 V AC
30 V DC
Nominal current IN1.5 A
Protective circuitunwired

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayNo
Status display presentNo

Connector
Connection 1
TypePlug straight M12 SPEEDCON
Number of positions17
Locking typeSPEEDCON
Coding typeA
Connection 2
TypeSocket straight M12 SPEEDCON
Number of positions17
Locking typeSPEEDCON
Coding typeA

Cable/line
Cable length0.2 m
Black PUR/PVC twisted pair [35T]
Dimensional drawing
Shieldedyes
UL AWM Style20233 / 1061 (80°C/300 V)
Cable weight105 kg/km
Cable typeBlack PUR/PVC twisted pair
Short symbolLSYWC11Y
Cable type (abbreviation)35T
External cable diameter9.2 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorblack RAL 9005
Material, inner sheathPVC
Conductor materialTin-plated Cu litz wires
Conductor structure signal line18x 0.10 mm
AWG signal line26
Conductor cross section17x 0.14 mm² (Signal line)
Material wire insulationPVC
Wire diameter incl. insulation1 mm ±0.05 mm (Signal line)
Single wire, colorwhite-brown, green-yellow, gray-pink, blue-red, black-violet, gray/pink-red/blue, white/green-brown/green, white/yellow-yellow/brown-white/gray
Overall twist7 pairs and 1 three-way unit, intertwisted
ShieldingTinned copper braided shield
Optical shield covering85 %
Nominal voltage, cable42 V AC
Test voltage, cable1500 V AC
Cable resistance142 Ω/km (at 20 °C)
Cable insulation resistance≥ 10 MΩ*km (at 20 °C)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Number of bending cycles4000000
Bending radius92 mm
Traversing path10 m
Traversing rate3 m/s
Acceleration10 m/s²
Resistance to oilin accordance with DIN EN 60811-2-1
Flame resistanceAccording to DIN EN 60332-1-2
According to VW-1
Other resistancehydrolysis and microbe resistant in accordance with EN 50396
Special propertiesFlexible cable conduit capable
Ambient temperature (operation)-5 °C ... 80 °C (Cable, flexible installation)
-30 °C ... 80 °C (cable, fixed installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
Ambient temperature (operation)-25 °C ... 85 °C (Plug / socket)
-40 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (Cable, flexible installation)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.