PHOENIX CONTACT SAC-10P-5,0-PUR/M16FRX SAC-10P- 5,0-PUR/M16FRX 1260750 PHOENIX CONTACT Main cable, application: Sensor/actuator box, number of plug.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-10P- 5,0-PUR/M16FRX 1260750 PHOENIX CONTACT Main cable, application: Sensor/actuator box, number of plug..

SAC-10P-5,0-PUR/M16FRX

1260750

PHOENIX CONTACT

1 Pcs.

Main cable, application: Sensor/actuator box, number of plug-in stations: 6, number of poles: 10, occupation of plug-in stations: single, status indication: No. main cable connection: M16 plug-in connection, PUR/PVC, cable length: 5 m, shielding: no, The item does not contain lead according to the RoHS II directive without exception 6c (Pb&lt.; 0.1 %) Main cable Output cable, application: Sensor/actuator box, connection type: M8 socket, number of slots: 6, number of poles: 10, slot occupancy: single, status signal: No; Main line connection: M16 connection, PUR/PVC, cable length: 5 m, shielding: no, The article is lead-free according to RoHS II without exception 6c (Pb < 0.1 %)

Automation > Sensor-actuator patch cord
Field Device Connectors (FDC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact SAC-10P-5,0-PUR/M16FRX is a main cable designed for sensor/actuator box applications, bridging localized signal nodes with central control architecture. Industrial distribution setups rely on such harnesses to aggregate multiple signals efficiently across factory machinery.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product Type: Packaged main line
  • No. of poles: 10
  • Application: Sensor/actuator box
  • Number of slots: 6
  • Rated voltage U N: 48 V AC
  • Link: Fixed attachment
  • Conductor cross-section AWG: (converted according to IEC)
  • Available Status Indication: no
  • Material: WHILE
  • Gasket material: NBR
  • Contact material on the output cable side: Cu alloy
  • Material contact inserts on the output cable side: TPU
  • Output cable side contact surface material: golden
  • Cable Length: 4 L
  • Line Weight: 81.2 kg/km
  • UL AWM Style: 20549

More info

▲
Technical data

Article features
Product TypePackaged main line
No. of poles10
ApplicationSensor/actuator box
Number of slots6

Electrical characteristics
Rated voltage UN48 V AC
60 V DC

Connection data
LinkFixed attachment
Conductor cross-section AWG(converted according to IEC)

Signalling
Available Status Indicationno

Material information
MaterialWHILE
Copper alloy
Gasket materialNBR
Contact material on the output cable sideCu alloy
Material contact inserts on the output cable sideTPU
Output cable side contact surface materialgolden

Cable/Line
Cable Length4 L
PUR/PVC Black [PUR]
Dimensioned Drawing
Line Weight81.2 kg/km
UL AWM Style20549
No. of poles8
Shieldedno
Cable TypePUR/PVC Black [PUR]
Line Signal Conductor Structure19x 0.15 mm
AWG Signal Line22
Conductor cross-section6x 0.34 mm² (Signal Line)
2x 0.75 mm² (Supply Line)
Wire diameter with insulating sheath1.3 mm ±0.1 mm (Signal Line)
1.8 mm ±0.1 mm (Power Line)
Conductor Outer Diameter7.6 mm ±0.2 mm
Outer Sheath, MaterialWHILE
Outer sheath, colorblack RAL 9005
Conductor materialBare Cu Wire
Material, Wire InsulationPVC
Single conductor, colorbrown, blue, white, green, yellow, gray, pink, red
Interior cladding wall thickness≥ 0.15 mm
Outer sheath wall thickness≥ 0.38 mm
Full strandingWires in twisted positions
Nominal cable voltage300 V
Test voltage2000 V
Minimum bending radius, fixed7.5 x D
Minimum bending radius, flexible10 x D
Minimum bending radius, fixed57 mm
Minimum bending radius, movable76 mm
Bending cycles, maximum1500000
Flame ResistanceDIN EN 50265
Oil Resistancein accordance with VDE 0472 Part 803
Other ResistanceVery good resistance against acids, lyes and solvents
Special featuressilicone-free
Ambient temperature (operating)-40 °C ... 90 °C (cables, fixed laying)
-5 °C ... 80 °C (Cables, mobile installation)
80 °C (according to UL)

Environmental and electrical life conditions
Environmental conditions
Degree of protectionIP67
Ambient temperature (operating)-25 °C ... 90 °C (Female Connector / Connector)
-40 °C ... 90 °C (cables, fixed laying)

Montage
LinkFixed attachment

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.