PHOENIX CONTACT FLK 40/EZ-DR/ 50/SLC FLK 40/EZ-DR/ 50/SLC 2294610 PHOENIX CONTACT Cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FLK 40/EZ-DR/ 50/SLC 2294610 PHOENIX CONTACT Cable

FLK 40/EZ-DR/ 50/SLC

2294610

PHOENIX CONTACT

1 Pcs.

Cable Ready-made round cable; control: Allen-Bradley SLC 500 (OB 32, IB 32); Connection 1: Female IDC/FLK connection (1x 40-poles); Connection 2: Female IDC/FLK connection (1x 40-pole); Cable length: 0.5 m

Cables > PLC connection cable
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

This Phoenix Contact FLK 40/EZ-DR/ 50/SLC cable ensures secure signal routing within modern industrial control architectures. Flat ribbon system cables are widely installed to connect programmable controllers to specialized interface modules with minimal space requirements. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Function (EF000030): PLC - other devices
  • Length (EF001438): 0.5 m
  • Suitable for input board PLC (EF008271): Yes
  • Suitable for output card PLC (EF008272): Yes
  • Suitable for digital signals (EF008273): Yes
  • Suitable for analogue signals (EF008274): No
  • Number of poles (EF001391): 40

More info

▲

Key Commercial Data

Orderkey2294610
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 478 (C-5-2017)
GTIN4017918148980
Weight per Piece (excluding packing)80.700 g
Custom tariff number85444290
Country of originDE (Germany)

General

Nominal voltage UN< 50 V AC
60 V DC
Max. current carrying capacity per path1 A
Max. conductor resistance0.16 Ω/m
Length of cable0.5 m
Single wire, cross section0.14 mm²
Single wire, cross section [AWG]26
Conductor construction: Number of litz wires:7
Single wire, materialCu tin-plated
Test voltage500 V AC (50 Hz, 1 min.)
External diameter10 mm
Cable, preassemblyInsulation displacement, IEC 60352-4/DIN EN 60352-4
Shieldingno

Environmental conditions

Ambient temperature (operation)-20 °C ... 50 °C
Ambient temperature (storage/transport)-20 °C ... 70 °C
Flame resistanceIEC 60332-1
DIN VDE 0482 Part 332-1

Connector 1

Connection nameField level
Connection methodIDC/FLK socket strip
Number of connections1
Number of positions40
Pitch2.54 mm

Connector 2

Connection nameController level
Connection methodIDC/FLK socket strip
Number of connections1
Number of positions40
Channels which can be connected32
Pitch2.54 mm

Supported controller

ControllerALLEN-BRADLEY SLC 500
- suitable I/O card1746 OB 32
1746 OV 32
1746 IB 32
1746 IV 32

Standards and Regulations

Flame resistanceIEC 60332-1
DIN VDE 0482 Part 332-1
Standards/regulationsDIN EN 60352-4
IEC 352-4

Color code

Connector 1 = connector 2 (optional) = wire colorIDC/FLK40 (1) = IDC/FLK40 (1) = black
IDC/FLK40 (2) = IDC/FLK40 (2) = brown
IDC/FLK40 (3) = IDC/FLK40 (3) = red
IDC/FLK40 (4) = IDC/FLK40 (4) = orange
IDC/FLK40 (5) = IDC/FLK40 (5) = yellow
IDC/FLK40 (6) = IDC/FLK40 (6) = green
IDC/FLK40 (7) = IDC/FLK40 (7) = blue
IDC/FLK40 (8) = IDC/FLK40 (8) = violet
IDC/FLK40 (9) = IDC/FLK40 (9) = gray
IDC/FLK40 (10) = IDC/FLK40 (10) = white
IDC/FLK40 (11) = IDC/FLK40 (11) = white-black
IDC/FLK40 (12) = IDC/FLK40 (12) = white-brown
IDC/FLK40 (13) = IDC/FLK40 (13) = white-red
IDC/FLK40 (14) = IDC/FLK40 (14) = white-orange
IDC/FLK40 (15) = IDC/FLK40 (15) = white-yellow
IDC/FLK40 (16) = IDC/FLK40 (16) = white-green
IDC/FLK40 (17) = IDC/FLK40 (17) = white-blue
IDC/FLK40 (18) = IDC/FLK40 (18) = white-violet
IDC/FLK40 (19) = IDC/FLK40 (19) = white-gray
IDC/FLK40 (20) = IDC/FLK40 (20) = brown-black
IDC/FLK40 (21) = IDC/FLK40 (21) = brown-red
IDC/FLK40 (22) = IDC/FLK40 (22) = brown-orange
IDC/FLK40 (23) = IDC/FLK40 (23) = brown-yellow
IDC/FLK40 (24) = IDC/FLK40 (24) = brown-green
IDC/FLK40 (25) = IDC/FLK40 (25) = brown-blue
IDC/FLK40 (26) = IDC/FLK40 (26) = brown-violet
IDC/FLK40 (27) = IDC/FLK40 (27) = brown-gray
IDC/FLK40 (28) = IDC/FLK40 (28) = brown-white
IDC/FLK40 (29) = IDC/FLK40 (29) = green-black
IDC/FLK40 (30) = IDC/FLK40 (30) = green-brown
IDC/FLK40 (31) = IDC/FLK40 (31) = green-red
IDC/FLK40 (32) = IDC/FLK40 (32) = green-orange
IDC/FLK40 (33) = IDC/FLK40 (33) = green-blue
IDC/FLK40 (34) = IDC/FLK40 (34) = green-violet
IDC/FLK40 (35) = IDC/FLK40 (35) = green-gray
IDC/FLK40 (36) = IDC/FLK40 (36) = green-white
IDC/FLK40 (37) = IDC/FLK40 (37) = yellow-black
IDC/FLK40 (38) = IDC/FLK40 (38) = yellow-brown
IDC/FLK40 (39) = IDC/FLK40 (39) = yellow-red
IDC/FLK40 (40) = IDC/FLK40 (40) = yellow-orange

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 5
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.