PHOENIX CONTACT FLK 26/EZ-DR/ 300/KONFEK FLK 26/EZ-DR/ 300/KONFEK 2299424 PHOENIX CONTACT Cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FLK 26/EZ-DR/ 300/KONFEK 2299424 PHOENIX CONTACT Cable

FLK 26/EZ-DR/ 300/KONFEK

2299424

PHOENIX CONTACT

1 Pcs.

Cable Ready-made round cable; Connection 1: IDC/FLK Connection Female (1x 26-poles); Connection 2: IDC/FLK Connection Female (1x 26-poles); Cable length: 3 m Round cable set; connection 1: IDC/FLK socket strip (1x 26-position); connection 2: IDC/FLK socket strip (1x 26-position); cable length: 3 m

Cables > PLC connection cable
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact cable FLK 26/EZ-DR/ 300/KONFEK serves as a pre-assembled system wiring solution that connects industrial automation control hardware to input and output interface modules. This connection type organizes multi-conductor pathways to maintain clean signal integrity inside electrical cabinets. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: System cable
  • Data management status Article revision: 04
  • Ambient conditions Degree of protection: IP00
  • Degree of protection (Installation location): ≥ IP54 (Installation location)
  • Ambient temperature (operation): -40 °C ... 70 °C (fixed installation)
  • Ambient temperature (storage/transport): -40 °C ... 80 °C
  • Altitude: ≤ 2000 m
  • Operating voltage (AC): ≤ 30 V AC
  • Operating voltage (DC): ≤ 60 V DC
  • Nominal operating mode: 100% operating factor
  • Current (Per path, 50°C): ≤ 1 A (Uncoiled, see derating)
  • Current (Per path, 70°C): ≤ 0.6 A (Uncoiled, see derating)
  • Cable length: 3 m
  • 26X0.14 [PVC] Number of positions: 26
  • Shielded: no
  • Cable type: 26X0.14 [PVC]

More info

▲
Technical data

Product properties
Product typeSystem cable
Data management status
Article revision04

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP00
Degree of protection (Installation location)≥ IP54 (Installation location)
Ambient temperature (operation)-40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m

Electrical properties
Operating voltage (AC)≤ 30 V AC
Operating voltage (DC)≤ 60 V DC
Nominal operating mode100% operating factor
Current (Per path, 50°C)≤ 1 A (Uncoiled, see derating)
Current (Per path, 70°C)≤ 0.6 A (Uncoiled, see derating)

Cable/line
Cable length3 m
26X0.14 [PVC]
Number of positions26
Shieldedno
Cable type26X0.14 [PVC]
Conductor typeRound cable set
Conductor structure signal line7x 0.16 mm
AWG signal line26
Conductor cross section26x 0.14 mm²
Wire diameter incl. insulation1 mm ±0.03 mm
External cable diameter8.30 mm ±0.4 mm
Outer sheath, materialSemi-rigid PVC
External sheath, colorgray
Conductor materialTin-plated Cu litz wires
Cable resistance≤ 145 Ω/km (20 °C)
Insulation resistance≥ 20 MΩ*km (20 °C)
Smallest bending radius, fixed installation70 mm
Smallest bending radius, movable installation131 mm
Dynamic load capacity (bending)Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter)
Halogen-freeno
Flame resistanceIEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1
Resistance to oilcan withstand occasional splashes (raw cable)
Cable typeCable for one module
Color code
blackIDC/FLK26 (1) = IDC/FLK26 (1)
brownIDC/FLK26 (2) = IDC/FLK26 (2)
redIDC/FLK26 (3) = IDC/FLK26 (3)
orangeIDC/FLK26 (4) = IDC/FLK26 (4)
yellowIDC/FLK26 (5) = IDC/FLK26 (5)
greenIDC/FLK26 (6) = IDC/FLK26 (6)
blueIDC/FLK26 (7) = IDC/FLK26 (7)
violetIDC/FLK26 (8) = IDC/FLK26 (8)
grayIDC/FLK26 (9) = IDC/FLK26 (9)
whiteIDC/FLK26 (10) = IDC/FLK26 (10)
white-blackIDC/FLK26 (11) = IDC/FLK26 (11)
white-brownIDC/FLK26 (12) = IDC/FLK26 (12)
white-redIDC/FLK26 (13) = IDC/FLK26 (13)
white-orangeIDC/FLK26 (14) = IDC/FLK26 (14)
white-yellowIDC/FLK26 (15) = IDC/FLK26 (15)
white-greenIDC/FLK26 (16) = IDC/FLK26 (16)
white-blueIDC/FLK26 (17) = IDC/FLK26 (17)
white-violetIDC/FLK26 (18) = IDC/FLK26 (18)
white-grayIDC/FLK26 (19) = IDC/FLK26 (19)
brown-blackIDC/FLK26 (20) = IDC/FLK26 (20)
brown-redIDC/FLK26 (21) = IDC/FLK26 (21)
brown-orangeIDC/FLK26 (22) = IDC/FLK26 (22)
brown-yellowIDC/FLK26 (23) = IDC/FLK26 (23)
brown-greenIDC/FLK26 (24) = IDC/FLK26 (24)
brown-blueIDC/FLK26 (25) = IDC/FLK26 (25)
brown-violetIDC/FLK26 (26) = IDC/FLK26 (26)

Connection data
Connection 1
Connection in acc. with standardbased on IEC 60603-13
Connection methodIDC/FLK socket strip
Number of connections1
Number of positions26
Insertion/withdrawal cycles> 50
Pitch2.54 mm
Connection 2
Connection in acc. with standardbased on IEC 60603-13
Connection methodIDC/FLK socket strip
Number of connections1
Number of positions26
Insertion/withdrawal cycles> 50
Pitch2.54 mm

Notes
Notes on operationFor proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.