View larger
CABLE-FLK50/OE/0,14/ 100 2305350 PHOENIX CONTACT Cable
CABLE-FLK50/OE/0,14/ 100
2305350
PHOENIX CONTACT
1 Pcs.
Cables > PLC connection cable
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for industrial control environments, the CABLE-FLK50/OE/0,14/ 100 2305350 PHOENIX CONTACT Cable serves as a high-density system cable for connecting PLC input and output modules to terminal blocks or relay boards. Its standardized multi-conductor layout ensures tidy, error-free wiring distribution across automation cabinets. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: System cable
- Data management status Article revision: 06
- Ambient conditions Degree of protection: IP00
- Degree of protection (Installation location): ≥ IP54 (Installation location)
- Ambient temperature (operation): -40 °C ... 70 °C (fixed installation)
- Ambient temperature (storage/transport): -40 °C ... 80 °C
- Altitude: ≤ 2000 m
- Operating voltage (AC): ≤ 30 V AC
- Operating voltage (DC): ≤ 60 V DC
- Nominal operating mode: 100% operating factor
- Current (Per path, 50°C): ≤ 1 A (Uncoiled, see derating)
- Current (Per path, 70°C): ≤ 0.6 A (Uncoiled, see derating)
- Cable length: 1 m
- 50X0.14 [PVC] UL AWM Style: 2464/1061
- Number of positions: 50
- Shielded: no
More info
▲| Product type | System cable |
| Data management status | |
| Article revision | 06 |
| Ambient conditions | |
| Degree of protection | IP00 |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation) |
| -10 °C ... 70 °C (flexible installation) | |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| Operating voltage (AC) | ≤ 30 V AC |
| Operating voltage (DC) | ≤ 60 V DC |
| Nominal operating mode | 100% operating factor |
| Current (Per path, 50°C) | ≤ 1 A (Uncoiled, see derating) |
| Current (Per path, 70°C) | ≤ 0.6 A (Uncoiled, see derating) |
| Cable length | 1 m |
| 50X0.14 [PVC] | |
| UL AWM Style | 2464/1061 |
| Number of positions | 50 |
| Shielded | no |
| Cable type | 50X0.14 [PVC] |
| Conductor type | Round cable set |
| Conductor structure signal line | 7x 0.16 mm |
| AWG signal line | 26 |
| Conductor cross section | 50x 0.14 mm² |
| Wire diameter incl. insulation | 1 mm ±0.03 mm |
| External cable diameter | 10.30 mm ±0.4 mm |
| Outer sheath, material | Semi-rigid PVC |
| External sheath, color | gray |
| Conductor material | Tin-plated Cu litz wires |
| Cable resistance | ≤ 145 Ω/km (20 °C) |
| Insulation resistance | ≥ 20 MΩ*km (20 °C) |
| Smallest bending radius, fixed installation | 86 mm |
| Smallest bending radius, movable installation | 161 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter) |
| Halogen-free | no |
| Flame resistance | IEC 60332-1-2 (raw cable) |
| VDE 0842, Part 332-1-2 (raw cable) | |
| IEC 60332-3-22 (raw cable) | |
| UL VW-1 | |
| CSA FT-1 | |
| Resistance to oil | can withstand occasional splashes (raw cable) |
| Cable type | Cable for one module |
| Color code | |
| black | IDC/FLK50 (1) = () |
| brown | IDC/FLK50 (2) = () |
| red | IDC/FLK50 (3) = () |
| orange | IDC/FLK50 (4) = () |
| yellow | IDC/FLK50 (5) = () |
| green | IDC/FLK50 (6) = () |
| blue | IDC/FLK50 (7) = () |
| violet | IDC/FLK50 (8) = () |
| gray | IDC/FLK50 (9) = () |
| white | IDC/FLK50 (10) = () |
| white-black | IDC/FLK50 (11) = () |
| white-brown | IDC/FLK50 (12) = () |
| white-red | IDC/FLK50 (13) = () |
| white-orange | IDC/FLK50 (14) = () |
| white-yellow | IDC/FLK50 (15) = () |
| white-green | IDC/FLK50 (16) = () |
| white-blue | IDC/FLK50 (17) = () |
| white-violet | IDC/FLK50 (18) = () |
| white-gray | IDC/FLK50 (19) = () |
| brown-black | IDC/FLK50 (20) = () |
| brown-red | IDC/FLK50 (21) = () |
| brown-orange | IDC/FLK50 (22) = () |
| brown-yellow | IDC/FLK50 (23) = () |
| brown-green | IDC/FLK50 (24) = () |
| brown-blue | IDC/FLK50 (25) = () |
| brown-violet | IDC/FLK50 (26) = () |
| brown-gray | IDC/FLK50 (27) = () |
| brown-white | IDC/FLK50 (28) = () |
| green-black | IDC/FLK50 (29) = () |
| green-brown | IDC/FLK50 (30) = () |
| green-red | IDC/FLK50 (31) = () |
| green-orange | IDC/FLK50 (32) = () |
| green-blue | IDC/FLK50 (33) = () |
| green-violet | IDC/FLK50 (34) = () |
| green-gray | IDC/FLK50 (35) = () |
| green-white | IDC/FLK50 (36) = () |
| yellow-black | IDC/FLK50 (37) = () |
| yellow-brown | IDC/FLK50 (38) = () |
| yellow-red | IDC/FLK50 (39) = () |
| yellow-orange | IDC/FLK50 (40) = () |
| yellow-blue | IDC/FLK50 (41) = () |
| yellow-violet | IDC/FLK50 (42) = () |
| yellow-gray | IDC/FLK50 (43) = () |
| yellow-white | IDC/FLK50 (44) = () |
| gray-black | IDC/FLK50 (45) = () |
| gray-brown | IDC/FLK50 (46) = () |
| gray-red | IDC/FLK50 (47) = () |
| gray-orange | IDC/FLK50 (48) = () |
| gray-yellow | IDC/FLK50 (49) = () |
| gray-green | IDC/FLK50 (50) = () |
| Connection 1 | |
| Connection method | Single wires |
| Stripping length (Sheath) | 150 mm |
| Number of positions | 50 |
| Note | The wires are marked and fitted with ferrules |
| Connection 2 | |
| Connection in acc. with standard | based on IEC 60603-13 |
| Connection method | IDC/FLK socket strip |
| Number of connections | 1 |
| Number of positions | 50 |
| Insertion/withdrawal cycles | > 50 |
| Pitch | 2.54 mm |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |