PHOENIX CONTACT CABLE-FLK20/OE/0,14/ 300 CABLE-FLK20/OE/0,14/ 300 2305347 PHOENIX CONTACT Cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CABLE-FLK20/OE/0,14/ 300 2305347 PHOENIX CONTACT Cable

CABLE-FLK20/OE/0,14/ 300

2305347

PHOENIX CONTACT

1 Pcs.

Cable Ready-made round cable; connection 1: Single conductors (20-poles) (Conductors are labeled and equipped with ferrules); Connection 2: Female IDC/FLK connection (1x 20-poles); Cable length: 3 m Round cable set; connection 1: Single wires (20-position) (The wires are marked and fitted with ferrules); connection 2: IDC/FLK socket strip (1x 20-position); cable length: 3 m

Cables > PLC connection cable
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

System cable type CABLE-FLK20/OE/0,14/ 300 by Phoenix Contact bridges the gap between controllers and field instrumentation, facilitating organized signal transmission in complex industrial environments. These pre-fabricated wiring solutions simplify installation by reducing manual termination errors in control cabinets and process automation systems.

Specific pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: System cable
  • Data management status Article revision: 06
  • Ambient conditions Degree of protection: IP00
  • Degree of protection (Installation location): ≥ IP54 (Installation location)
  • Ambient temperature (operation): -40 °C ... 70 °C (fixed installation)
  • Ambient temperature (storage/transport): -40 °C ... 80 °C
  • Altitude: ≤ 2000 m
  • Operating voltage (AC): ≤ 30 V AC
  • Operating voltage (DC): ≤ 60 V DC
  • Nominal operating mode: 100% operating factor
  • Current (Per path, 50°C): ≤ 1 A (Uncoiled, see derating)
  • Current (Per path, 70°C): ≤ 0.6 A (Uncoiled, see derating)
  • Cable length: 3 m
  • 20X0.14 [PVC] UL AWM Style: 2464/1061
  • Number of positions: 20
  • Shielded: no

More info

▲
Technical data

Product properties
Product typeSystem cable
Data management status
Article revision06

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP00
Degree of protection (Installation location)≥ IP54 (Installation location)
Ambient temperature (operation)-40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m

Electrical properties
Operating voltage (AC)≤ 30 V AC
Operating voltage (DC)≤ 60 V DC
Nominal operating mode100% operating factor
Current (Per path, 50°C)≤ 1 A (Uncoiled, see derating)
Current (Per path, 70°C)≤ 0.6 A (Uncoiled, see derating)

Cable/line
Cable length3 m
20X0.14 [PVC]
UL AWM Style2464/1061
Number of positions20
Shieldedno
Cable type20X0.14 [PVC]
Conductor typeRound cable set
Conductor structure signal line7x 0.16 mm
AWG signal line26
Conductor cross section20x 0.14 mm²
Wire diameter incl. insulation1 mm ±0.03 mm
External cable diameter7.60 mm ±0.4 mm
Outer sheath, materialSemi-rigid PVC
External sheath, colorgray
Conductor materialTin-plated Cu litz wires
Cable resistance≤ 145 Ω/km (20 °C)
Insulation resistance≥ 20 MΩ*km (20 °C)
Smallest bending radius, fixed installation64 mm
Smallest bending radius, movable installation120 mm
Dynamic load capacity (bending)Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter)
Halogen-freeno
Flame resistanceIEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1
Resistance to oilcan withstand occasional splashes (raw cable)
Cable typeCable for one module
Color code
blackIDC/FLK20 (1) = ()
brownIDC/FLK20 (2) = ()
redIDC/FLK20 (3) = ()
orangeIDC/FLK20 (4) = ()
yellowIDC/FLK20 (5) = ()
greenIDC/FLK20 (6) = ()
blueIDC/FLK20 (7) = ()
violetIDC/FLK20 (8) = ()
grayIDC/FLK20 (9) = ()
whiteIDC/FLK20 (10) = ()
white-blackIDC/FLK20 (11) = ()
white-brownIDC/FLK20 (12) = ()
white-redIDC/FLK20 (13) = ()
white-orangeIDC/FLK20 (14) = ()
white-yellowIDC/FLK20 (15) = ()
white-greenIDC/FLK20 (16) = ()
white-blueIDC/FLK20 (17) = ()
white-violetIDC/FLK20 (18) = ()
white-grayIDC/FLK20 (19) = ()
brown-blackIDC/FLK20 (20) = ()

Connection data
Connection 1
Connection methodSingle wires
Stripping length (Sheath) 150 mm
Number of positions20
NoteThe wires are marked and fitted with ferrules
Connection 2
Connection in acc. with standardbased on IEC 60603-13
Connection methodIDC/FLK socket strip
Number of connections1
Number of positions20
Insertion/withdrawal cycles> 50
Pitch2.54 mm

Notes