View larger
RIF-1-RPT-LDP-24DC/2X21/FG 2908215 PHOENIX CONTACT Relay Module
RIF-1-RPT-LDP-24DC/2X21/FG
2908215
PHOENIX CONTACT
10 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An RIF-1-RPT-LDP-24DC/2X21/FG 2908215 PHOENIX CONTACT Relay Module is a standard electromechanical switching device used in control panels to isolate control circuits from load circuits and handle multiple signal paths. Units of this type provide reliable galvanic separation, status visibility, and interface matching between low-power controllers and industrial actuators. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Complete with socket (EF003359): Yes
- With detachable clamps (EF003340): No
- With LED indication (EF005950): Yes
- Rated control supply voltage DC (EF003980): 20.4 V
- Voltage type for actuating (EF008242): DC
- Drive, polarization (EF003355): Polarized
- Drive, switching attitude (EF003356): Mono stable
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as normally open contact (EF008256): 0
- Number of contacts as change-over contact (EF008257): 2
- Type of switch contact (EF003358): Single contact
- With forced-guided contacts (EF003357): Yes
- Material of contact surface (EF004020): Untreated
- Nominal current (EF000001): 0.03 A
- Degree of protection (IP) (EF005474): IP20
- Width (EF000008): 16 mm
More info
▲Key Commercial Data
| Orderkey | 2908215 |
|---|---|
| Packing unit | 10 pc |
| Catalog page | Page 456 (C-5-2017) |
| GTIN | 4055626289151 |
| Weight per Piece (excluding packing) | 71.520 g |
| Custom tariff number | 85364110 |
| Country of origin | CZ (Czech Republic) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 50 °C |
|---|---|
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
Coil side
| Nominal input voltage UN | 24 V DC |
|---|---|
| Input voltage range in reference to UN | see diagram |
| Typical input current at UN | 30 mA |
| Typical response time | 10 ms |
| Typical release time | 10 ms |
| Coil voltage | 24 V DC |
| Protective circuit | Damping diode |
| Operating voltage display | Yellow LED |
| Power dissipation for nominal condition | 0.72 W |
Contact side
| Contact type | 2 changeover contacts, forcibly actuated |
|---|---|
| Type of switch contact | Single contact |
| Contact material | AgNi |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 15 V AC/DC |
| Min. switching current | 10 mA |
| Maximum inrush current | 6 A |
| Limiting continuous current | 6 A |
| Interrupting rating (ohmic load) max. | 144 W (at 24 V DC) |
| 288 W (at 48 V DC) | |
| 88 W (at 110 V DC) | |
| 110 W (at 220 V DC) | |
| 1500 VA (for 250 V AC) | |
| Switching capacity | 2 A (at 24 V, DC13) |
| 3 A (at 230 V, AC15) |
Connection data 1
| Connection name | Coil side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| 0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve) | |
| 0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block) | |
| Conductor cross section AWG | 26 ... 16 (solid) |
| 26 ... 16 (flexible) |
Connection data 2
| Connection name | Contact side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| 0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve) | |
| 0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block) | |
| Conductor cross section AWG | 26 ... 16 (solid) |
| 26 ... 16 (flexible) |
General
| Operating mode | 100% operating factor |
|---|---|
| Degree of protection | IP20 (Relay base) |
| RT II (Relay) | |
| Mechanical service life | approx. 107cycles |
| UL, USA/Canada | cULus listed UL 508 |
| UL certificate | NRNT.E172140 |
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
| B10d | 600000 Cycles (AC1; 250 V / 6 A; 1 NO) |
| 900000 Cycles (AC1; 250 V / 3 A; 1 NO) | |
| 1800000 Cycles (AC1; 250 V / 1,5 A; 1 NO) | |
| 180000 Cycles (AC15; 250 V / 3 A; 1 NO) | |
| 560000 Cycles (AC15; 250 V / 2 A; 1 NO) | |
| 4600000 Cycles (AC15; 250 V / 0,75 A; 1 NO) | |
| 360000 Cycles (DC13; 24 V / 3 A; 1 NO) | |
| 740000 Cycles (DC13; 24 V / 1,5 A; 1 NO) | |
| 4200000 Cycles (DC13; 24 V / 0,75 A; 1 NO) | |
| Net weight (SAP) | 71.52 g |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178/VDE 0160 |
| EN 50205 | |
| Rated insulation voltage | 250 V |
| Rated surge voltage | 6 kV |
| Insulation | safe isolation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Flammability rating according to UL 94 | V2 |
| Conformance | CE-compliant |
| UL, USA/Canada | cULus listed UL 508 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |