PHOENIX CONTACT ELR W3-24DC/500AC-2I ELR W3- 24DC/500AC- 2I 2297031 PHOENIX CONTACT Hybrid motor starter View larger
Images are for illustrative purposes only. Please refer to data sheet for details

ELR W3- 24DC/500AC- 2I 2297031 PHOENIX CONTACT Hybrid motor starter

ELR W3-24DC/500AC-2I

2297031

PHOENIX CONTACT

1 Pcs.

Hybrid motor starter Inver contactor. semicon. three-phase "4 in 1" with 24 V DC input, corr. 2 A output, emergency stop and disconnect function. by envelope. fit.

Automation > Motor starter/Motor starter combination
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Hybrid motor starter built with solid-state technology to provide high-lifecycle reversing control for industrial motors. Such devices integrate multiple functions including braking, reversing, and overload protection within a compact housing.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Type of motor starter (EF009598): Reversing starter
  • With short-circuit release (EF006691): No
  • Rated control supply voltage DC (EF003980): 19.2 V
  • Voltage type for actuating (EF008242): DC
  • Rated operation current Ie (EF001443): 2.4 A
  • Rated operation current at AC-3, 400 V (EF009602): 2.4 A
  • Overload release current setting (EF002336): 0.18 A
  • Temperature compensated overload protection (EF009604): No
  • Release class (EF006668): CLASS 10
  • Type of electrical connection of main circuit (EF006819): Screw connection
  • Suitable for rail mounting (EF003972): Yes
  • Number of command positions (EF001372): 1
  • Suitable for emergency stop (EF001433): Yes
  • External reset possible (EF003426): Yes
  • Degree of protection (IP) (EF005474): IP20
  • Width (EF000008): 22.5 mm

More info

▲

Key Commercial Data

Orderkey2297031
Packing unit1 pc
Catalog pagePage 18 (C-7-2013)
GTIN4046356167864
Weight per Piece (excluding packing)282.700 g
Custom tariff number85371098
Country of originDE (Germany)

Width22.5 mm
Height106.6 mm
Depth113.7 mm
Ambient temperature (operation)-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Degree of protectionIP20

Device supply

Rated control circuit supply voltage US24 V DC
Control supply voltage range19.2 V DC ... 30 V DC
Rated control supply current IS40 mA
Type of protectionSurge protection
Reverse polarity protection

Input data

Input nameControl input right/left
Rated actuating voltage UC24 V DC
Triggering voltage range19.2 V DC ... 30 V DC
Rated actuating current IC5 mA
Switching threshold9.6 V (“0” signal)
19.2 V (“1” signal)
Switching level< 5 V DC (For EMERGENCY STOP)
Typical response time< 35 ms
Typical turn-off time< 40 ms

Output data load output

Output nameAC output
Rated operating voltage Ue500 V AC
Operating voltage range42 V AC ... 550 V AC
Rated operating current Ie2.4 A (AC-51)
2.4 A (AC-53a)
Mains frequency50/60 Hz
Load current range180 mA ... 2.4 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2Class 10A
Cooling time20 min. (for auto reset)
Leakage current0 mA
Residual voltage< 0.3 V
Surge current100 A (t = 10 ms)
Type of protectionSurge protection

Output data reply output

Output nameAcknowledge output
NoteConfirmation: floating change-over contact, signal contact
Contact type1 PDT
Switching capacity according to IEC 60947-5-13 A (230 V, AC15)
2 A (24 V, DC13)

General

Switching frequency≤ 2 Hz (Load-dependent)
Mounting positionVertical (horizontal DIN rail)
Mounting typeDIN rail mounting
Assembly instructionsCan be aligned with spacing = 20 mm
Operating mode100% operating factor
Maximum power dissipation3.3 W
Minimum power dissipation1.1 W
Operating voltage displayGreen LED
Status displayYellow LED
IndicationRed LED

Connection nameControl circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm
Connection nameLoad circuit
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm

UL data

SCCR100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
5 kA (500 V AC (fuse: 20 A RK5 (standard fault)))
FLA2.4 A (500 V AC)
Group installation20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Category codeNLDX

Insulation characteristics

Rated insulation voltage500 V
Rated surge voltage6 kV
Overvoltage categoryIII
Degree of pollution2
DesignationInsulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit
InsulationSafe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC
Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC
Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC
DesignationIsolation characteristics between the control input and control supply voltage to auxiliary circuit
InsulationSafe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC

Standards and Regulations

DesignationStandards/regulations
Standards/regulationsDIN EN 50178
EN 60947
IEC 61508
ISO 13849
ATEX II (2) G [Ex e] [Ex d] [Ex px]
 II (2) D [Ex t] [Ex p]

Approvals/conformities

Safety Integrity Level according to IEC 61508≤ 3 (Safe shutdown)
2 (Motor protection)
Category acc. to EN ISO 13849≤ 3 (Safe shutdown)
Performance level according to ISO 13849≤ e (Safe shutdown)
ATEX II (2) G [Ex e] [Ex d] [Ex px]
 II (2) D [Ex t] [Ex p]
EU-type examination certificatePTB 07 ATEX 3145
UL certificateNLDX.E228652

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.