View larger
VAL-MS 1000DC-PV-ST 2800624 PHOENIX CONTACT Type 2 surge protection plug
VAL-MS 1000DC-PV-ST
2800624
PHOENIX CONTACT
1 Pcs.
Automation > Accessories/spare parts for surge protection power supply systems
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A VAL-MS 1000DC-PV-ST 2800624 PHOENIX CONTACT Type 2 surge protection plug safeguards sensitive electrical systems by diverting voltage spikes safely to ground. Protective devices of this classification are commonly deployed in industrial automation panels and distribution boards to ensure continuous operational uptime and protect connected hardware from transient disturbances. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2800624
- Packing unit: 1 pc
- Catalog page: Page 65 (C-4-2017)
- GTIN: 4046356615099
- Weight per Piece (excluding packing): 68.600 g
- Custom tariff number: 85363010
- Country of origin: DE (Germany)
- Height: 52.4 mm
- Width: 17.5 mm
- Depth: 55.3 mm
- Horizontal pitch: 1 Div.
- Degree of protection: IP20
- Ambient temperature (operation): -40 °C ... 80 °C
- Ambient temperature (storage/transport): -40 °C ... 80 °C
- Altitude: ≤ 2000 m (amsl (above mean sea level))
- Permissible humidity (operation): 5 % ... 95 %
More info
▲Key Commercial Data
| Orderkey | 2800624 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 65 (C-4-2017) |
| GTIN | 4046356615099 |
| Weight per Piece (excluding packing) | 68.600 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -40 °C ... 80 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Permissible humidity (operation) | 5 % ... 95 % |
| Shock (operation) | 60g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Vibration (operation) | 7.5g (5-500 Hz/2.5 h/XYZ) |
General
| IEC test classification | PV II |
|---|---|
| PV T2 | |
| EN type | T2 |
| SPD failure behavior | OCM (Open-circuit mode) |
| Installation location | Inside |
| Accessibility | Accessible |
| Installation location of the disconnect device | Internal |
| Mounting type | on base element |
| Color | jet black RAL 9005 |
| Housing material | PA 6.6-FR |
| Degree of pollution | 2 |
| Flammability rating according to UL 94 | V-0 |
| Type | Male |
| Surge protection fault message | optical |
Protective circuit DC voltage side (DC)
| Maximum continuous operating voltage UCPV | 585 V DC |
|---|---|
| Short-circuit current rating ISCPV | 2000 A |
| Continuous operating current ICPV | < 20 µA |
| Standby power consumption PC | ≤ 25 mVA |
| Nominal discharge current (8/20) µs | 15 kA |
| Maximum discharge current Imax(8/20) µs | 40 kA |
| Voltage protection level Up | ≤ 1.9 kV |
| Residual voltage Ures | ≤ 1.9 kV (at In) |
| ≤ 1.5 kV (at 5 kA) | |
| ≤ 1.7 kV (at 10 kA) | |
| ≤ 2 kV (at 20 kA) | |
| ≤ 2.3 kV (at 30 kA) | |
| ≤ 2.5 kV (at 40 kA) | |
| Response time tA | ≤ 25 ns |
| Insulation resistance Riso | > 5 GΩ (at 500 V DC) |
UL specifications
| SPD Type | 1CA |
|---|---|
| Maximum continuous operating voltage MCOV | 1170 V DC |
| Nominal voltage | 1170 V DC |
| Mode of protection | (L+) - (L-) |
| (L+) - G | |
| (L-) - G | |
| Power distribution system | DC PV |
| Voltage protection rating VPR | 3 kV |
| Nominal discharge current In | 10 kA |
| Short-circuit current rating (SCCR) | 50 kA |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |