View larger
VAL-MS-T1/T2 1000DCPV-UD-ST 2801231 PHOENIX CONTACT Type 1/2 surge protection plug
VAL-MS-T1/T2 1000DCPV-UD-ST
2801231
PHOENIX CONTACT
1 Pcs.
Automation > Accessories/spare parts for surge protection power supply systems
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact VAL-MS-T1/T2 1000DCPV-UD-ST Type 1/2 surge protection plug provides advanced transient overvoltage mitigation for high-capacity photovoltaic power installations. These modular plug elements mount onto specialized base blocks to divert severe electrical surges away from sensitive solar inverters and monitoring systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2801231
- Packing unit: 1 pc
- Note: Made to Order (non-returnable)
- Catalog page: Page 59 (C-6-2015)
- GTIN: 4046356749220
- Weight per Piece (excluding packing): 94.700 g
- Custom tariff number: 85363030
- Country of origin: DE (Germany)
- Height: 52.4 mm
- Width: 17.5 mm
- Depth: 55.3 mm
- Horizontal pitch: 1 Div.
- Degree of protection: IP20
- Ambient temperature (operation): -40 °C ... 80 °C
- Ambient temperature (storage/transport): -40 °C ... 80 °C
- Altitude: ≤ 2000 m (amsl (above mean sea level))
More info
▲Key Commercial Data
| Orderkey | 2801231 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 59 (C-6-2015) |
| GTIN | 4046356749220 |
| Weight per Piece (excluding packing) | 94.700 g |
| Custom tariff number | 85363030 |
| Country of origin | DE (Germany) |
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -40 °C ... 80 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Permissible humidity (operation) | 5 % ... 95 % |
| Shock (operation) | 60g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Vibration (operation) | 7.5g (5-500 Hz/2.5 h/XYZ) |
General
| IEC test classification | PV T1 |
|---|---|
| PV T2 | |
| SPD failure behavior | OCM (Open-circuit mode) |
| Installation location | Inside |
| Accessibility | Accessible |
| Installation location of the disconnect device | Internal |
| Mounting type | on base element |
| Color | jet black RAL 9005 |
| Housing material | PA 6.6-FR |
| Degree of pollution | 2 |
| Flammability rating according to UL 94 | V-0 |
| Type | Male |
| Number of positions | 1 |
| Surge protection fault message | optical |
Protective circuit DC voltage side (DC)
| Maximum continuous operating voltage UCPV | 525 V DC |
|---|---|
| Short-circuit current rating ISCPV | 1000 A |
| Continuous operating current ICPV | < 20 µA |
| Standby power consumption PC | ≤ 25 mVA |
| Nominal discharge current (8/20) µs | 15 kA |
| Maximum discharge current Imax(8/20) µs | 40 kA |
| Impulse discharge current (10/350) µs, charge | 2.5 As |
| Impulse discharge current (10/350) µs, specific energy | 6.25 kJ/Ω |
| Impulse discharge current (10/350) µs, peak value limp | 5 kA |
| Voltage protection level Up | ≤ 1.8 kV |
| Residual voltage Ures | ≤ 1.8 kV (at In) |
| ≤ 1.5 kV (at 5 kA) | |
| ≤ 1.7 kV (at 10 kA) | |
| ≤ 1.9 kV (at 20 kA) | |
| ≤ 2.2 kV (at 30 kA) | |
| ≤ 2.4 kV (at 40 kA) | |
| Response time tA | ≤ 25 ns |
| Insulation resistance Riso | > 5 GΩ (at 500 V DC) |
UL specifications
| SPD Type | 4CA |
|---|---|
| Maximum continuous operating voltage MCOV (L+) - G | 1050 V DC |
| Nominal voltage | 875 V DC |
| Mode of protection | (L+) - G |
| Power distribution system | Single phase |
| Measured limiting voltage MLV (L+) - G | 1900 V |
| Nominal discharge current In(L+) - G | 20 kA |