PSM-ME-RS485/RS485-P 2744429 PHOENIX CONTACT Repeater
PSM-ME-RS485/RS485-P
2744429
PHOENIX CONTACT
1 Pcs.
Automation > PLC communication module
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact repeater, part number PSM-ME-RS485/RS485-P, is built to extend transmission distances and regenerate signal integrity in multi-drop industrial serial communication networks. Technicians install repeaters in heavy industrial setups to protect data signals against electromagnetic interference and maintain stable network performance over extended cable runs. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Note on application Note on application: Only for industrial use
- Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area
- Utilization restriction CCCex note: Use in potentially explosive areas is not permitted in China.
- Product type: Interface converter
- Application: RS-485
- MTTF: 1808 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
- Data management status Article revision: 19
- Insulation characteristics Pollution degree: 2
- Electrical isolation: VCC // RS-485 (A) // RS-485 (B)
- Maximum power dissipation for nominal condition: 2.16 W
- Test voltage data interface/power supply: 1.5 kV rms (50 Hz, 1 min.)
- Supply Supply voltage range: 18 V AC/DC ... 30 V AC/DC (via pluggable COMBICON screw terminal block)
- Nominal supply voltage: 24 V AC/DC
- Typical current consumption: 90 mA (24 V DC)
- Max. current consumption: 100 mA
- Supply Single conductor/terminal point, rigid: 0.2 mm² ... 2.5 mm²
More info
▲| Note on application | |
| Note on application | Only for industrial use |
| Utilization restriction | |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| Utilization restriction | |
| CCCex note | Use in potentially explosive areas is not permitted in China. |
| Product type | Interface converter |
| Application | RS-485 |
| MTTF | 1808 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| 796 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
| 334 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) | |
| Data management status | |
| Article revision | 19 |
| Insulation characteristics | |
| Pollution degree | 2 |
| Electrical isolation | VCC // RS-485 (A) // RS-485 (B) |
| Maximum power dissipation for nominal condition | 2.16 W |
| Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
| Supply | |
| Supply voltage range | 18 V AC/DC ... 30 V AC/DC (via pluggable COMBICON screw terminal block) |
| Nominal supply voltage | 24 V AC/DC |
| Typical current consumption | 90 mA (24 V DC) |
| Max. current consumption | 100 mA |
| Supply | |
| Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² |
| Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section, flexible [AWG] | 24 ... 12 |
| Tightening torque | 0.56 Nm ... 0.79 Nm |
| Bit distortion | < 1.5 % |
| Bit distortion, input | max. ± 35 % |
| Bit distortion, output | < 3.6 % |
| Bit delay | < 200 ns |
| Signal | Modbus |
| Transmission channels | 2 (1/1), TD, RD, half duplex |
| Data: RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire | |
| Serial transmission speed | 1.2 / 2.4 / 4.8 / 9.6 / 19.2 / 38.4 / 57.6 / 75 / 93.75 / 115.2 / 136 / 187.5 / 375 / 500 / 1500 kbps |
| Connection method | Pluggable screw connection |
| Transmission length | ≤ 1200 m (depends on transmission speed, bus system and cable type) |
| Cascadability | 9 (4,8 ... 93,75 kbps) |
| 8 (115.2 kbps) | |
| 7 (136 kbps) | |
| 6 (187.5 kbps) | |
| 5 (375 ... 1500 kbps) | |
| Termination resistor | 390 Ω |
| 180 Ω | |
| 390 Ω (Can be connected) | |
| Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
| Max. AWG conductor cross section, flexible | 12 |
| Min. AWG conductor cross section, flexible | 24 |
| Transmission medium | 2-wire twisted pair, shielded |
| File format/coding | UART (11/10 bit switchable; NRZ) |
| Data direction switching | Automatic control, min. station response time 1 bits |
| Protocols supported | transparent protocol |
| Data: RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire | |
| Serial transmission speed | 1.2 / 2.4 / 4.8 / 9.6 / 19.2 / 38.4 / 57.6 / 75 / 93.75 / 115.2 / 136 / 187.5 / 375 / 500 / 1500 kbps |
| Transmission length | ≤ 1200 m (depends on transmission speed, bus system and cable type) |
| Cascadability | 9 (4,8 ... 93,75 kbps) |
| 8 (115.2 kbps) | |
| 7 (136 kbps) | |
| 6 (187.5 kbps) | |
| 5 (375 ... 1500 kbps) | |
| Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
| Max. AWG conductor cross section, flexible | 12 |
| Min. AWG conductor cross section, flexible | 24 |
| Transmission medium | 2-wire twisted pair, shielded |
| File format/coding | UART (11/10 bit switchable; NRZ) |
| Data direction switching | Automatic control, min. station response time 1 bits |
| Protocols supported | transparent protocol |
| Dimensional drawing | |
| Width | 22.5 mm |
| Height | 99 mm |
| Depth | 114.5 mm |
| Color (Housing) | green (RAL 6021) |
| Material (Housing) | PA 6.6-FR |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| CE | |
| Certificate | CE-compliant |
| ATEX | |
| Identification | II 3 G Ex nA IIC T4 Gc |
| Certificate | IBExU16ATEXB004 X |
| Note | Please follow the special installation instructions in the documentation! |
| IECEx | |
| Identification | Ex nA IIC T4 Gc |
| Certificate | IECEx IBE 15.0034X |
| UL, USA/Canada | |
| Identification | 508 Recognized |
| Class I, Div. 2, Groups A, B, C, D | |
| Class I, Zone 2, AEx nA IIC T4 | |
| Class I, Zone 2, Ex nA IIC T4 Gc X | |
| KC approval for South Korea | |
| Certificate | KCC-REI-PCK-FL2744429 |
| Corrosive gas test | |
| Identification | ISA-S71.04-1985 G3 Harsh Group A |
| Shipbuilding | |
| Identification | DNV GL |
| DNV GL data | |
| Temperature | B |
| Humidity | A |
| Vibration | A |
| EMC | B |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Noise immunity | EN 61000-6-2:2005 |
| Noise emission | EN 61000-6-4 |
| Electrostatic discharge | |
| Standards/regulations | EN 61000-4-2 |
| Electrostatic discharge | |
| Contact discharge | ± 6 kV (Test Level 3) |
| Discharge in air | ± 8 kV (Test Level 3) |
| Indirect discharge | ± 6 kV (Test Level 3) |
| Comments | Criterion B |
| Electromagnetic HF field | |
| Standards/regulations | EN 61000-4-3 |
| Electromagnetic HF field | |
| Frequency range | 26 MHz ... 3 GHz (Test Level 3) |
| Field intensity | 10 V/m |
| Comments | Criterion A |
| Fast transients (burst) | |
| Standards/regulations | EN 61000-4-4 |
| Fast transients (burst) | |
| Input | ± 4 kV (Test Level 3) |
| Signal | ± 2 kV (Test Level 3) |
| Comments | Criterion B |
| Surge current load (surge) | |
| Standards/regulations | EN 61000-4-5 |
| Surge current load (surge) | |
| Input | ± 0.5 kV (DC supply) |
| Signal | ± 2 kV (Data line, asymmetrical) |
| Comments | Criterion B |
| Conducted interference | |
| Standards/regulations | EN 61000-4-6 |
| Conducted interference | |
| Frequency range | 0.15 MHz ... 80 MHz |
| Comments | Criterion A |
| Voltage | 10 V |
| Emitted interference | |
| Standards/regulations | EN 55011 |
| Comments | Class A, industrial applications |
| Criteria | |
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Mounting type | DIN rail mounting |