View larger
IBS RBC METER-T 2806286 PHOENIX CONTACT Remote bus cable
IBS RBC METER-T
2806286
PHOENIX CONTACT
1 m.
Cables > Data and communication cable
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The IBS RBC METER-T 2806286 PHOENIX CONTACT Remote bus cable is engineered to connect distributed input and output modules within industrial controller networks. Modular automation layouts rely on dedicated bus lines to maintain synchronized data exchange between the main controller and remote terminal units. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Nominal cross section conductor (EF000060): 0.22 mm²
- Conductor category (EF001632): Class 2 = stranded
- Number of cores (EF001792): 6
- Specification core insulation (EF011805): Polyethylene (PE)
- Screen over stranding element (EF001623): Braiding
- Longitudinal water blocking cable (EF011011): No
- Radial water blocking cable (EF011012): No
- Suitable for underground installation (EF003689): No
- Material outer sheath (EF001625): Polyvinyl chloride (PVC)
- Low smoke according to EN IEC 61034-2 (EF003799): No
- Oil resistant according to EN IEC 60811-404 (EF009770): No
- Outer diameter approx. (EF003921): 7 mm
More info
▲Key Commercial Data
| Orderkey | 2806286 |
|---|---|
| Packing unit | 1 M |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 333 (C-8-2013) |
| GTIN | 4017918074791 |
| Weight per Piece (excluding packing) | 70.160 g |
| Custom tariff number | 85444993 |
| Country of origin | DE (Germany) |
Cable
| Signal type/category | INTERBUS |
|---|---|
| Cable structure | 3 x 2 x 0.22 mm² |
| Conductor cross section | 3x 2x 0.22 mm² |
| Conductor structure signal line | 7x 0.20 mm |
| Wire colors | Green-yellow, white-brown, gray-pink |
| Twisted pairs | 2 cores to the pair |
| Overall twist | 3 pairs to the core |
| Shielding | Braided copper wires |
| External sheath, color | may green RAL 6017 |
| External cable diameter D | 7 mm |
| Minimum bending radius, fixed installation | 7.5 x D |
| Minimum bending radius, flexible installation | 15 x D |
| Outer sheath, material | PVC |
| Material conductor insulation | PE |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 5 GΩ*km |
| Loop resistance | ≤ 186.00 Ω/km |
| Cable capacity | ≤ 60 nF/km (At 800 Hz) |
| Wave impedance | 120 Ω ±20 % (at 64 kHz) |
| 100 Ω ±15 % (with 1 MHz) | |
| Near end crosstalk attenuation (NEXT) | ≥ 61 dB (at 772 kHz) |
| ≥ 59 dB (with 1 MHz) | |
| ≥ 55 dB (at 2 МHz) | |
| ≥ 50 dB (at 4 МHz) | |
| ≥ 46 dB (at 8 МHz) | |
| ≥ 44 dB (at 10 MHz) | |
| ≥ 41 dB (at 16 MHz) | |
| ≥ 40 dB (at 20 МHz) | |
| Attenuation | ≤ 15 dB/km (at 256 kHz) |
| ≤ 24 dB/km (at 772 kHz) | |
| ≤ 27 dB/km (with 1 MHz) | |
| ≤ 52 dB/km (at 4 МHz) | |
| ≤ 84 dB/km (at 10 MHz) | |
| ≤ 112 dB/km (at 16 MHz) | |
| ≤ 119 dB/km (at 20 МHz) | |
| Signal speed | 0.66 c |
| Coupling resistance | < 250.00 mΩ/m (at 30 MHz) |
| Nominal voltage, cable | 250 V (Peak value, not for high-power applications) |
| Test voltage Core/Core | 1500 Vrms |
| Test voltage Core/Shield | 1000 Vrms |
| Flame resistance | according to VDE 0472, Part 4, test type B |
| according to IEC 60332-1 | |
| Ambient temperature (operation) | -30 °C ... 70 °C (cable, fixed installation) |
| -5 °C ... 70 °C (cable, flexible installation) |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |