The Phoenix Contact REL-MR-12DC/21-21/C1D2 2906988 PHOENIX CONTACT Single relay functions as a core electromechanical switching unit designed to handle electrical load management within automated manufacturing installations. Single relays provide dependable circuit isolation and switching capabilities for general automation needs.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Single relay
- Operating mode: 100% operating factor
- Mechanical service life: 3x 10 7 cycles
- Data management status Date of last data management: 02.05.2024
- Article revision: 01
- Insulation characteristics Insulation: Basic insulation
- Overvoltage category: III
- Pollution degree: 3
- Service life electrical: see diagram
- Maximum power dissipation for nominal condition: 0.4 W
- Test voltage (Winding/contact): 5 kV AC (50 Hz, 1 min., winding/contact)
- Test voltage (Contact/contact): 2.5 kV AC (50 Hz, 1 min., contact/contact)
- Coil side Nominal input voltage U N: 12 V DC
- Input voltage range: 9.4 V DC ... 29.8 V DC
- Input voltage range in reference to U N: see diagram
- Drive and function: monostable
More info
▲| Product type | Single relay |
| Operating mode | 100% operating factor |
| Mechanical service life | 3x 107cycles |
| Data management status | |
| Date of last data management | 02.05.2024 |
| Article revision | 01 |
| Insulation characteristics | |
| Insulation | Basic insulation |
| Overvoltage category | III |
| Pollution degree | 3 |
| Service life electrical | see diagram |
| Maximum power dissipation for nominal condition | 0.4 W |
| Test voltage (Winding/contact) | 5 kV AC (50 Hz, 1 min., winding/contact) |
| Test voltage (Contact/contact) | 2.5 kV AC (50 Hz, 1 min., contact/contact) |
| Coil side | |
| Nominal input voltage UN | 12 V DC |
| Input voltage range | 9.4 V DC ... 29.8 V DC |
| Input voltage range in reference to UN | see diagram |
| Drive and function | monostable |
| Drive (polarity) | non-polarized |
| Typical input current at UN | 33 mA |
| Typical response time | 7 ms |
| Typical release time | 3 ms |
| Coil resistance | 360 Ω ±10 % (at 20 °C) |
| Switching | |
| Contact switching type | 2 changeover contacts |
| Type of switch contact | Single contact |
| Contact material | AgNi |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 5 V (at 10 mA) |
| Limiting continuous current | 8 A |
| Maximum inrush current | 25 A (20 ms) |
| Min. switching current | 10 mA (At 5 V) |
| Interrupting rating (ohmic load) max. | 190 W (at 24 V DC) |
| 85 W (at 48 V DC) | |
| 60 W (at 60 V DC) | |
| 44 W (at 110 V DC) | |
| 60 W (at 220 V DC) | |
| 2000 VA (for 250 V AC) | |
| Switching capacity | 2 A (at 24 V, DC13) |
| 0.2 A (at 250 V, DC13) | |
| 3 A (at 24 V, AC15) | |
| 3 A (at 120 V, AC15) | |
| 3 A (at 250 V, AC15) | |
| Connection method | Plug / solder connection |
| Dimensional drawing | |
| Width | 12.7 mm |
| Height | 29 mm |
| Depth | 15.7 mm |
| Color | orange (RAL 2003) |
| Ambient conditions | |
| Degree of protection | RT III |
| Ambient temperature (operation) | -40 °C ... 85 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Corrosive gas test | |
| Identification | ISA-S71.04. G3 Harsh Group |
| EN 60068-2-60 | |
| Standards/regulations | IEC 60664 |
| EN 50178 |
| Assembly note | Can be aligned without spacing (> 70 °C ≥ 2.5 mm) |
| Mounting position | any |