View larger
REL-MR-110DC/1IC 1081621 PHOENIX CONTACT Pluggable miniature power relay, with power contact for high switch..
REL-MR-110DC/1IC
1081621
PHOENIX CONTACT
10 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact REL-MR-110DC/1IC 1081621 is a pluggable miniature power relay, with power contact for high switching capacities, deployed to control heavy loads and manage circuit transitions safely. Power relays handle high-current switching requirements within industrial equipment.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1081621
- Packing unit: 1
- GTIN: 4055626810317
- Custom tariff number: 85364900
- Width: 12.7 mm
- Height: 29 mm
- Depth: 15.7 mm
- Ambient temperature (operation): -40 °C ... 85 °C
- Ambient temperature (storage/transport): -40 °C ... 85 °C
- Maximum altitude: ≤ 2000 m
- Degree of protection: RT II
- Nominal input voltage U N: 110 V DC
- Input voltage range in reference to U N: see diagram
- Typical input current at U N: 3.8 mA
- Typical response time: 8 ms
- Typical release time: 3 ms
More info
▲Ambient conditions
| Ambient temperature (operation) | -40 °C ... 85 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Maximum altitude | ≤ 2000 m |
| Degree of protection | RT II |
Coil side
| Nominal input voltage UN | 110 V DC |
|---|---|
| Input voltage range in reference to UN | see diagram |
| Typical input current at UN | 3.8 mA |
| Typical response time | 8 ms |
| Typical release time | 3 ms |
| Coil resistance | 28880 Ω ±10 % (20 °C) |
| Power dissipation for nominal condition | 0.42 W |
Contact side
| Contact type | 1 N/O contact |
|---|---|
| Type of switch contact | Single contact |
| Contact material | AgSnO |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 12 V (100 mA) |
| Min. switching current | 100 mA (at 12 V DC) |
| Maximum inrush current | 80 A (20 ms) |
| 130 A (peak, at capacitive load, 230 V AC, 24 μF) | |
| Limiting continuous current | 16 A |
| Interrupting rating (ohmic load) max. | 384 W (at 24 V DC) |
| 58 W (at 48 V DC) | |
| 48 W (at 60 V DC) | |
| 50 W (at 110 V DC) | |
| 80 W (at 220 V DC) | |
| 4000 VA (for 250 V AC) | |
| Switching capacity min. | 1200 mW |
General
| Test voltage relay winding/relay contact | 5 kV AC (50 Hz, 1 min.) |
|---|---|
| Operating mode | 100% operating factor |
| Mechanical service life | 3x 107cycles |
| Mounting position | any |
| Assembly instructions | Can be aligned without spacing (> 70 °C ≥ 2.5 mm) |
Standards and Regulations
| Standards/regulations | EN 50178 |
|---|---|
| EN 61810-1 | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 6 kV |
| Insulation | Safe isolation, reinforced insulation |
| Pollution degree | 3 |
| Overvoltage category | III |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |